American Bio Medica Corp.


Address: 603 Heron Dr., Unit 3, Logan Township, New Jersey 08085, USA
Phone: +1-(856)-241-2320 | Map/Directions >>
 
 

Profile: American Bio Medica Corp. offers methadone test system, methamphetamine test system, one step lateral flow immunoassay, and propoxyphene test system.

FDA Registration Number: 2249781

31 Products/Services (Click for related suppliers)  
• Amphetamine Enzyme Immunoassay Test (FDA Code: DKZ / 862.3100)
An amphetamine test system is a device intended to measure amphetamine, a central nervous system stimulating drug, in plasma and urine. Measurements obtained by this device are used in the diagnosis and treatment of amphetamine use or overdose and in monitoring levels of amphetamine to ensure appropriate therapy.
• Amphetamine Gas Chromatography Test (FDA Code: DOD / 862.3100)
• Barbiturate Enzyme Immunoassay Test (FDA Code: DIS / 862.3150)
A barbiturate test system is a device intended to measure barbiturates, a class of hypnotic and sedative drugs, in serum, urine, and gastric contents. Measurements obtained by this device are used in the diagnosis and treatment of barbiturate use or overdose and in monitoring levels of barbiturate to ensure appropriate therapy.
• Benzodiazepine Enzyme Immunoassay Test (FDA Code: JXM / 862.3170)
A benzodiazepine test system is a device intended to measure any of the benzodiazepine compounds, sedative and hypnotic drugs, in blood, plasma, and urine. The benzodiazepine compounds include chlordiazepoxide, diazepam, oxazepam, chlorzepate, flurazepam, and nitrazepam. Measurements obtained by this device are used in the diagnosis and treatment of benzodiazepine use or overdose and in monitoring levels of benzodiazepines to ensure appropriate therapy.
• Cannabinoids Enzyme Immunoassay Test (FDA Code: LDJ / 862.3870)
A cannabinoid test system is a device intended to measure any of the cannabinoids, hallucinogenic compounds endogenous to marihuana, in serum, plasma, saliva, and urine. Cannabinoid compounds includedelta -9-tetrahydrocannabinol, cannabidiol, cannabinol, and cannabichromene. Measurements obtained by this device are used in the diagnosis and treatment of cannabinoid use or abuse and in monitoring levels of cannabinoids during clinical investigational use.
• Cholinesterase Test Paper (FDA Code: DIG / 862.3240)
A cholinesterase test system is a device intended to measure cholinesterase (an enzyme that catalyzes the hydrolysis of acetylcholine to choline) in human specimens. There are two principal types of cholinesterase in human tissues. True cholinesterase is present at nerve endings and in erythrocytes (red blood cells) but is not present in plasma. Pseudo cholinesterase is present in plasma and liver but is not present in erythrocytes. Measurements obtained by this device are used in the diagnosis and treatment of cholinesterase inhibition disorders (e.g., insecticide poisoning and succinylcholine poisoning).
• Cocaine and Cocaine Metabolites Enzyme Immunoassay Test (FDA Code: DIO / 862.3250)
A cocaine and cocaine metabolite test system is a device intended to measure cocaine and a cocaine metabolite (benzoylecgonine) in serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment of cocaine use or overdose.
• Diagnostic Membranes for Lateral Flow Assays
• Fluorometer for Clinical Use (FDA Code: KHO / 862.2560)
A fluorometer for clinical use is a device intended to measure by fluorescence certain analytes. Fluorescence is the property of certain substances of radiating, when illuminated, a light of a different wavelength. This device is used in conjunction with certain materials to measure a variety of analytes.
• High Pressure Liquid Chromatography for Tricyclic Antidepressant Drugs (FDA Code: LFI / 862.3910)
A tricyclic antidepressant drugs test system is a device intended to measure any of the tricyclic antidepressant drugs in serum. The tricyclic antidepressant drugs include imipramine, desipramine, amitriptyline, nortriptyline, protriptyline, and doxepin. Measurements obtained by this device are used in the diagnosis and treatment of chronic depression to ensure appropriate therapy.
• Immunoassay Systems
• Immunoassays
• Metamphetamine Thin Layer Chromatography Test (FDA Code: DJC / 862.3610)
A methamphetamine test system is a device intended to measure methamphetamine, a central nervous system stimulating drug, in serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment of methamphetamine use or overdose.
• Methadone Enzyme Immunoassay Test (FDA Code: DJR / 862.3620)
A methadone test system is a device intended to measure methadone, an addictive narcotic pain-relieving drug, in serum and urine. Measurements obtained by this device are used in the diagnosis and treatment of methadone use or overdose and to determine compliance with regulations in methadone maintenance treatment.
• Methadone Test Strip
• Methamphetamine Gas Chromatography Test (FDA Code: LAF / 862.3610)
• Methamphetamine High Pressure Liquid Chromatography Test (FDA Code: LAG / 862.3610)
• Methamphetamine Test Strip
• Morphine Gas Chromatography Test (FDA Code: DMY / 862.3640)
A morphine test system is a device intended to measure morphine, an addictive narcotic pain-relieving drug, and its analogs in serum, urine, and gastric contents. Measurements obtained by this device are used in the diagnosis and treatment of morphine use or overdose and in monitoring levels of morphine and its analogs to ensure appropriate therapy.
• Morphine Liquid Chromatography Test (FDA Code: DPK / 862.3640)
• Opiates Enzyme Immunoassay Test (FDA Code: DJG / 862.3650)
An opiate test system is a device intended to measure any of the addictive narcotic pain-relieving opiate drugs in blood, serum, urine, gastric contents, and saliva. An opiate is any natural or synthetic drug that has morphine-like pharmocological actions. The opiates include drugs such as morphine, morphine glucoronide, heroin, codeine, nalorphine, and meperedine. Measurements obtained by this device are used in the diagnosis and treatment of opiate use or overdose and in monitoring the levels of opiate administration to ensure appropriate therapy.
• Opiates Gas Chromatography Test (FDA Code: DJF / 862.3650)
• Phencyclidine Enzyme Immunoassay (FDA Code: LCM)
• Phencyclidine Radioimmunoassay Test (FDA Code: LCL)
• Propoxyphene Enzyme Immunoassay (FDA Code: JXN / 862.3700)
A propoxyphene test system is a device intended to measure propoxyphene, a pain-relieving drug, in serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment of propoxyphene use or overdose or in monitoring levels of propoxyphene to ensure appropriate therapy.
• Propoxyphene Urine Drug Test
• Respiratory Syncytial CF Antigen (FDA Code: GQG / 866.3480)
Respiratory syncytial virus serological reagents are devices that consist of antigens and antisera used in serological tests to identify antibodies to respiratory syncytial virus in serum. Additionally, some of these reagents consist of respiratory syncytial virus antisera conjugated with a fluorescent dye (immunofluorescent reagents) and used to identify respiratory syncytial viruses from clinical specimens or from tissue culture isolates derived from clinical specimens. The identification aids in the diagnosis of respiratory syncytial virus infections and provides epidemiological information on diseases caused by these viruses. Respiratory syncytial viruses cause a number of respiratory tract infections, including the common cold, pharyngitis, and infantile bronchopneumonia.
• Salicylate Thin Layer Chromatography (FDA Code: DJE / 862.3830)
A salicylate test system is a device intended to measure salicylates, a class of analgesic, antipyretic and anti-inflammatory drugs that includes aspirin, in human specimens. Measurements obtained by this device are used in diagnosis and treatment of salicylate overdose and in monitoring salicylate levels to ensure appropriate therapy.
• Tetrahydrocannabinol Test (FDA Code: DKE / 862.3870)
• Transferrin Antigen (FDA Code: DDG / 866.5880)
A transferrin immunological test system is a device that consists of the reagents used to measure by immunochemical techniques the transferrin (an iron-binding and transporting serum protein) in serum, plasma, and other body fluids. Measurement of transferrin levels aids in the diagnosis of malnutrition, acute inflammation, infection, and red blood cell disorders, such as iron deficiency anemia.
• Tricyclic Antidepressant Drugs Radioimmunoassay Test (FDA Code: LFG / 862.3910)