Profile: Anesthesia Associates Inc. manufactures durable reusable products for anesthesia & respiratory care professionals. We supply fiber-optic & conventional laryngoscopes, manometers, latex free items, nerve stimulators, CO2 absorbers, digital & analog respirometers and special material configurations. We have authorized repair centers for respirometers and peak flow meters. Our Gioflex is an adaptable and reliable device that allows for secure flexible positioning of various size anesthesia tubing between the equipment & the patient. It is particularly beneficial during ENT and neuro applications where access to the patient's head and ET tube is limited. It clamps to the OR table rail with unlimited positions and measures 21 inches in length.
The company was founded in 1958, has revenues of < USD 1 Million and is ISO certified.
FDA Registration Number: 2022648
51 to 72 of 72 Products/Services (Click for related suppliers) Page: 1 [2]
|
• Non-Rebreathing Valve (FDA Code: CBP / 868.5870) A nonrebreathing valve is a one-way valve that directs breathing gas flow to the patient and vents exhaled gases into the atmosphere. |
• Non-Ventilatory Medicinal Nebulizer/Atomizer (FDA Code: CCQ / 868.5640) A medicinal nonventilatory nebulizer (atomizer) is a device that is intended to spray liquid medication in aerosol form into the air that a patient will breathe. |
• Oxygen Sensors |
• Peripheral Nerve Stimulators |
• Pocket Spirometer & Mouthpieces |
• Positive End Expiratory Pressure Breathing Attachment (FDA Code: BYE / 868.5965) A positive end expiratory pressure (PEEP) breathing attachment is a device attached to a ventilator that is used to elevate pressure in a patient's lungs above atmospheric pressure at the end of exhalation. |
• Powered Emergency Ventilator/Resuscitator (FDA Code: BTL / 868.5925) A powered emergency ventilator is a demand valve or inhalator intended to provide emergency respiratory support by means of a face mask or a tube inserted into a patient's airway. |
• Pressure Manometers |
• Pulse Oximeters |
• Reservoir Bag (FDA Code: BTC / 868.5320) A reservoir bag is a device, usually made of conductive rubber, intended for use in a breathing circuit as a reservoir for breathing gas and to assist, control, or monitor a patient's ventilation. |
• Rigid Laryngoscope (FDA Code: CCW / 868.5540) A rigid laryngoscope is a device used to examine and visualize a patient's upper airway and aid placement of a tracheal tube. |
• Scavenging Adapters |
• Scavenging Valves |
• Spirometers |
• Spirometry Peak Flow Meter (FDA Code: BZH / 868.1860) A peak-flow meter for spirometry is a device used to measure a patient's maximum ventilatory flow rate. |
• Stethoscope Head (FDA Code: BZS / 868.1930) A stethoscope head is a weighted chest piece used during anesthesia to listen to a patient's heart, breath, and other physiological sounds. |
• Switching Valve (FDA Code: JFE / 868.1965) A switching valve (ploss) is a three-way valve located between a stethoscope placed over the heart, a blood pressure cuff, and an earpiece. The valve allows the user to eliminate one sound channel and listen only to a patient's heart or korotkoff (blood pressure) sounds through the other channel. |
• Tracheal Tube Cleaning Brushes (FDA Code: EPE / 868.5795) A tracheal tube cleaning brush is a device consisting of a brush with plastic bristles intended to clean tracheal cannula devices after their removal from patients. |
• Tracheal Tube Stylet (FDA Code: BSR / 868.5790) A tracheal tube stylet is a device used temporarily to make rigid a flexible tracheal tube to aid its insertion into a patient. |
• Tube Introduction Forceps (FDA Code: BWB / 868.5780) Tube introduction forceps (e.g., Magill forceps) are a right-angled device used to grasp a tracheal tube and place it in a patient's trachea. |
• Ventilator Breathing Circuits |
• Y Piece Breathing Circuit (FDA Code: CAI / 868.5240) An anesthesia breathing circuit is a device that is intended to administer medical gases to a patient during anesthesia. It provides both an inhalation and exhalation route and may include a connector, adaptor, and Y-piece. |