Profile: Autosuture offers a complete line of surgical products and instrumentation that surgeons utilize for laparoscopic, endoscopic & traditional open surgical procedures & lymphatic mapping. We are an ISO 9001, ISO 9002, CE MARK certified company. We offer products like endo catchT 10mm specimen bag, endo catchT II 15mm specimen bag, LDST powered 15W single use stapler, LDST 15W single use loading unit & ProTackT 5mm single use instrument. Our Autosuture™ Endo Clip™ MultApplier™ reusable clip applier is designed for use with the endo Clip™ MultApplier™ single-use loading unit, each of which contains eight titanium clips.

The company has revenues of > USD 1 Billion, has ~5780 employees and is ISO 9001, ISO 9002, CE certified.

551 to 600 of 647 Products/Services (Click for related suppliers)  Page: << Previous 50 Results 1 2 3 4 5 6 7 8 9 10 11 [12] 13 >> Next 50 Results
• Surgical Sponge Counter (FDA Code: LWH / 880.2740)
A surgical sponge scale is a nonelectrically powered device used to weigh surgical sponges that have been used to absorb blood during surgery so that, by comparison with the known dry weight of the sponges, an estimate may be made of the blood lost by the patient during surgery.
• Surgical Staple Applier (FDA Code: GEF / 878.4800)
A manual surgical instrument for general use is a nonpowered, hand-held, or hand-manipulated device, either reusable or disposable, intended to be used in various general surgical procedures. The device includes the applicator, clip applier, biopsy brush, manual dermabrasion brush, scrub brush, cannula, ligature carrier, chisel, clamp, contractor, curette, cutter, dissector, elevator, skin graft expander, file, forceps, gouge, instrument guide, needle guide, hammer, hemostat, amputation hook, ligature passing and knot-tying instrument, knife, blood lancet, mallet, disposable or reusable aspiration and injection needle, disposable or reusable suturing needle, osteotome, pliers, rasp, retainer, retractor, saw, scalpel blade, scalpel handle, one-piece scalpel, snare, spatula, stapler, disposable or reusable stripper, stylet, suturing apparatus for the stomach and intestine, measuring tape, and calipers. A surgical instrument that has specialized uses in a specific medical specialty is classified in separate regulations in parts 868 through 892.
• Surgical Staplers, Circular Staplers
• Surgical Staplers, Laparoscopic Staplers
• Surgical Staplers, Open Clip Appliers
• Surgical Staplers, Stainless Steel Staples
• Surgical Staplers, Titanium Staples
• Surgical Tissue Forceps
• Surgical Trays (FDA Code: LRP / 878.4800)
• Surgical Trays (FDA Code: LRP / 878.4800)
• Surgical Urethral Catheter (FDA Code: GBM / 876.5130)
A urological catheter and accessories is a flexible tubular device that is inserted through the urethra and used to pass fluids to or from the urinary tract. This generic type of device includes radiopaque urological catheters, ureteral catheters, urethral catheters, coudecatheters, balloon retention type catheters, straight catheters, upper urinary tract catheters, double lumen female urethrographic catheters, disposable ureteral catheters, male urethrographic catheters, and urological catheter accessories including ureteral catheter stylets, ureteral catheter adapters, ureteral catheter holders, ureteral catheter stylets, ureteral catheterization trays, and the gastro-urological irrigation tray (for urological use).
• Suture Anchors
• Suture Free Wound Closure Adhesives
• Suture Needles
• Suture Removal Kit (FDA Code: MCZ / 878.4800)
• Suture Retention Device (FDA Code: KGS / 878.4930)
A suture retention device is a device, such as a retention bridge, a surgical button, or a suture bolster, intended to aid wound healing by distributing suture tension over a larger area in the patient.
• Suture Scissors
• Suture tying Forceps
• Sutures
• Suturing Kits & Removal Kits
• Swabs, Fan Retractors
• Swiss Cilia Forceps
• Synthetic Absorbable Suture (FDA Code: GAN / 878.4830)
An absorbable surgical gut suture, both plain and chromic, is an absorbable, sterile, flexible thread prepared from either the serosal connective tissue layer of beef (bovine) or the submucosal fibrous tissue of sheep (ovine) intestine, and is intended for use in soft tissue approximation.
• Synthetic Casting Materials
• Syringe Needle Introducer (FDA Code: KZH / 880.6920)
A syringe needle introducer is a device that uses a spring-loaded mechanism to drive a hypodermic needle into a patient to a predetermined depth below the skin surface.
• Table Operating Room Accessories (FDA Code: FWZ / 878.4950)
A manual operating table and accessories and a manual operating chair and accessories are nonpowered devices, usually with movable components, intended to be used to support a patient during diagnostic examinations or surgical procedures.
• Tapered Orbital Retractors
• Temporary Pacemaker Electrode (FDA Code: LDF / 870.3680)
A temporary pacemaker electrode is a device consisting of flexible insulated electrical conductors with one end connected to anexternal pacemaker pulse generator and the other end applied to the heart. The device is used to transmit a pacing electrical stimulus from the pulse generator to the heart and/or to transmit the electrical signal of the heart to the pulse generator.
• Tenotomy Scissors
• Therapeutic Intravascular Catheter (FDA Code: LJS / 880.5970)
A percutaneous, implanted, long-term intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings, such as luer hubs, and accessories that facilitate the placement of the device. The device allows for repeated access to the vascular system for long-term use of 30 days or more, and it is intended for administration of fluids, medications, and nutrients; the sampling of blood; and monitoring blood pressure and temperature. The device may be constructed of metal, rubber, plastic, composite materials, or any combination of these materials and may be of single or multiple lumen design.
• Therapeutic Vaginal Douche Apparatus (FDA Code: HED / 884.5900)
A therapeutic vaginal douche apparatus is a device that is a bag or bottle with tubing and a nozzle. The apparatus does not include douche solutions. The apparatus is intended and labeled for use in the treatment of medical conditions except it is not for contraceptive use. After filling the therapeutic vaginal douche apparatus with a solution, the patient uses the device to direct a stream of solution into the vaginal cavity.
• Thermal Regulating System (FDA Code: DWJ / 870.5900)
A thermal regulating system is an external system consisting of a device that is placed in contact with the patient and a temperature controller for the device. The system is used to regulate patient temperature.
• Thin capsulorhexis Forceps
• Thoracic Trocar
• Thoracic Trocar Catheter
• Threaded Fixation Pin (FDA Code: JDW / 888.3040)
A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.
• Thumb Dressing Forceps
• Tipless Stone Extractors
• Tissue Retractors
• Tissue Thickness Gauge
• Titanium Bayonet Forceps
• Titanium Bipolar Forceps (Ophthalmology)
• Titanium Mayo Scissors
• Titanium RETINAL Forceps
• Titanium Suture Scissors
• Titanium vitreoretinal Intraocular Forceps
• Topical Approximation of Skin Tissue Adhesive (FDA Code: MPN / 878.4010)
• Tracheal Tube Fixation Device (FDA Code: CBH / 868.5770)
A tracheal tube fixation device is a device used to hold a tracheal tube in place, usually by means of straps or pinch rings.
• Tracheal Tube Stylet (FDA Code: BSR / 868.5790)
A tracheal tube stylet is a device used temporarily to make rigid a flexible tracheal tube to aid its insertion into a patient.
• Tracheal Tube with/without Connector (FDA Code: BTR / 868.5730)
A tracheal tube is a device inserted into a patient's trachea via the nose or mouth and used to maintain an open airway.