Profile: AViTA Corporation is a manufacturer & distributor of point-of-care health products designed for clinical and personal use. We are a complete OEM/ODM solutions provider, & our wide range of production include body composition analyzers, blood pressure monitors, blood glucose monitors, digital thermometers, and nasal care devices. Avita products include infrared thermometer-in-ear, infrared thermometer-forehead, multi-function, nasal aspiration, blood glucose meters, blood pressure monitor-arm unit, wrist unit, and wireless products. TS2 series are accurate & can eliminate the problem of transmission deviation due to the cover's material which is waterproof probe design. TS2 is a non-wave guide design which is reliable, and compact with automatic calibrating production system. TS12 is a forehead temperature measurement design specificaly for measuring forehead temperature with power-on-self-test & waterproof probe design. TS23 is a 3 in 1 special design which includes the function for measuring ear temperature, forehead temperature, and ambient temperature with time indication, power-on-self-test, big LCD screen, and back light display. BPM-91 series has the largest LCD with simultaneous information design, World Health Organization Indicator, power saving design, low battery symbol and alarm clock. BP-65 series has a unique stand design with ambient temperature showing, LCD display, SID, and 2 zone memory.
The company was founded in 1996.
FDA Registration Number: 9617543
US Agent: John Belistreri
Phone: +1-(830)-562-3001 Fax: +1-(858)-712-1998 E-Mail:
5 Products/Services (Click for related suppliers)
|
• Body Composition Analyzer (FDA Code: MNW / 870.2770) An impedance plethysmograph is a device used to estimate peripheral blood flow by measuring electrical impedance changes in a region of the body such as the arms and legs. |
• Continuous Electronic Thermometer (FDA Code: FLL / 880.2910) A clinical electronic thermometer is a device used to measure the body temperature of a patient by means of a transducer coupled with an electronic signal amplification, conditioning, and display unit. The transducer may be in a detachable probe with or without a disposable cover. |
• Non-Invasive Blood-Pressure Measurement System (FDA Code: DXN / 870.1130) A noninvasive blood pressure measurement system is a device that provides a signal from which systolic, diastolic, mean, or any combination of the three pressures can be derived through the use of tranducers placed on the surface of the body. |
• Powered Nasal Irrigator (FDA Code: KMA / 874.5550) A powered nasal irrigator is an AC-powered device intended to wash the nasal cavity by means of a pressure-controlled pulsating stream of water. The device consists of a control unit and pump connected to a spray tube and nozzle. |
• Radiofrequency Physiological Transmitter/Receiver System (FDA Code: DRG / 870.2910) A radiofrequency physiological signal transmitter and receiver is a device used to condition a physiological signal so that it can be transmitted via radiofrequency from one location to another, e.g., a central monitoring station. The received signal is reconditioned by the device into its original format so that it can be displayed. |