Serim Research Corp. | Address: P.O. Box 4002, 3506 Reedy Drive, Elkhart, Indiana 46514-0002, USA USA
www.serim.com | Send Inquiry | Phone: +1-(574)-264-3440, 542-4670
FDA Registration: 1833387
Products: Helicobacter pylori Urease Test Kits, Glutaraldehyde Test Strips, Blood Leak Test Strips, PeriScreen Test Strips, Chlorine Sanitizer Strips, Water Quality Test Strips, ...
Serim Research Corp. develops & markets test strips based on our dry reagent technology. We are an ISO 9001 and ISO 13485 certified company. Technology created and developed at our facility includes c more...
 
Enviromental Test System Inc | Address: P.O. Box 4659, Elkhart, Indiana 46514-0659, USA USA
www.etsstrips.com | Send Inquiry | Phone: +1-(574)-262-2060
FDA Registration: 1833407  Annual Revenues: USD 100-500 Million  Quality: ISO 9001, CE Certified
Products: General Diagnostic Supplies, General Medical Supplies, General Diagnostics, General Examination Supplies, Specialty Diagnostic Supplies, Sterilization Equipment Test, ...
Environmental Test Systems Inc manufactures and markets chemical test systems. We are known for our use of dry reagent test strip technology. Our products offer easy, reliable methods of detecting and more...
 EMAIL INQUIRY to  2 Blood Leakage Detector suppliers  
FDA Code / Regulation: FJD / 876.5820

A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.

Classification. (1) Class II (performance standards) for hemodialysis systems and all accessories directly associated with the extracorporeal blood system and the dialysate delivery system.

 BROWSE BY CATEGORY > Urology OR VIEW PRODUCTS UNDER Urology