Profile: Cayenne Medical, Inc. specializes in iFix, and crossfix systems. These implants are made of polyetheretherketone, a material with strength, biocompatibility & ideal modulus, enabling surgeons to perform anterior cruciate ligament reconstruction using the hamstring and other soft tissue grafts. The iFix interference screw system is ideal for reconstruction procedures using the bone-patellar tendon-bone and other bone-tendon-bone grafts. CrossFix™ system is the next generation meniscal repair device that offers surgeons the benefits of both open suturing and arthroscopic meniscal repair.
FDA Registration Number: 3006108336
7 Products/Services (Click for related suppliers)
|
• Bone Fixation Screw (FDA Code: HWC / 888.3040) A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system. |
• Drill Bit (FDA Code: HTW / 888.4540) An orthopedic manual surgical instrument is a nonpowered hand-held device intended for medical purposes to manipulate tissue, or for use with other devices in orthopedic surgery. This generic type of device includes the cerclage applier, awl, bender, drill brace, broach, burr, corkscrew, countersink, pin crimper, wire cutter, prosthesis driver, extractor, file, fork, needle holder, impactor, bending or contouring instrument, compression instrument, passer, socket positioner, probe, femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. |
• Femoral Fixation Device |
• Interference Screw Systems |
• Meniscal Repair Devices |
• Orthopedic Manual Surgical Instrument (FDA Code: LXH / 888.4540) |
• Polyethylene Synthetic Non-Absorbable Suture (FDA Code: GAT / 878.5000) Nonabsorbable poly(ethylene terephthalate) surgical suture is a multifilament, nonabsorbable, sterile, flexible thread prepared from fibers of high molecular weight, long-chain, linear polyesters having recurrent aromatic rings as an integral component and is indicated for use in soft tissue approximation. The poly(ethylene terephthalate) surgical suture meets U.S.P. requirements as described in the U.S.P. Monograph for Nonabsorbable Surgical Sutures; it may be provided uncoated or coated; and it may be undyed or dyed with an appropriate FDA listed color additive. Also, the suture may be provided with or without a standard needle attached. |