Profile: Cook Vascular Incorporated provides interventional, therapeutic and diagnostic vascular products. We also manufacture a complete line of Vital-port® vascular access ports and a wide variety of catheters, introducers & specialty components. Our lead extraction system is a collection of specialized tools designed to aid in the percutaneous removal of cardiac leads and catheters. Our Cook-Swartz doppler flow probe and monitor system has been created to meet the need for an effective tool to assess vascular patency. Our components are used in both superior and femoral approach extraction procedures.

FDA Registration Number: 2522007

25 Products/Services (Click for related suppliers)  
• Assisted Reproduction Microtools (FDA Code: MQH / 884.6130)
Assisted reproduction microtools are pipettes or other devices used in the laboratory to denude, micromanipulate, hold, or transfer human gametes or embryos for assisted hatching, intracytoplasmic sperm injection (ICSI), or other assisted reproduction methods.
• Catheter Dilator (FDA Code: GCC / 878.4200)
An introduction/drainage catheter is a device that is a flexible single or multilumen tube intended to be used to introduce nondrug fluids into body cavities other than blood vessels, drain fluids from body cavities, or evaluate certain physiologic conditions. Examples include irrigation and drainage catheters, pediatric catheters, peritoneal catheters (including dialysis), and other general surgical catheters. An introduction/drainage catheter accessory is intended to aid in the manipulation of or insertion of the device into the body. Examples of accessories include adaptors, connectors, and catheter needles.
• Catheter Introducers (FDA Code: DYB / 870.1340)
A catheter introducer is a sheath used to facilitate placing a catheter through the skin into a vein or artery.
• Central catheter, Single Chamber Systems
• Diagnostic Ultrasonic Transducer (FDA Code: ITX / 892.1570)
A diagnostic ultrasonic transducer is a device made of a piezoelectric material that converts electrical signals into acoustic signals and acoustic signals into electrical signals and intended for use in diagnostic ultrasonic medical devices. Accessories of this generic type of device may include transmission media for acoustically coupling the transducer to the body surface, such as acoustic gel, paste, or a flexible fluid container.
• Doppler Flow Devices
• Dual Chamber Systems
• Dual Chamber Systems Silicone
• Electrosurgical Cutting and Coagulation Device (FDA Code: GEI / 878.4400)
An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.
• Embolectomy Catheters (FDA Code: DXE / 870.5150)
An embolectomy catheter is a balloon-tipped catheter that is used to remove thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to another.
• General Surgical Manual Instrument (FDA Code: MDM / 878.4800)
A manual surgical instrument for general use is a nonpowered, hand-held, or hand-manipulated device, either reusable or disposable, intended to be used in various general surgical procedures. The device includes the applicator, clip applier, biopsy brush, manual dermabrasion brush, scrub brush, cannula, ligature carrier, chisel, clamp, contractor, curette, cutter, dissector, elevator, skin graft expander, file, forceps, gouge, instrument guide, needle guide, hammer, hemostat, amputation hook, ligature passing and knot-tying instrument, knife, blood lancet, mallet, disposable or reusable aspiration and injection needle, disposable or reusable suturing needle, osteotome, pliers, rasp, retainer, retractor, saw, scalpel blade, scalpel handle, one-piece scalpel, snare, spatula, stapler, disposable or reusable stripper, stylet, suturing apparatus for the stomach and intestine, measuring tape, and calipers. A surgical instrument that has specialized uses in a specific medical specialty is classified in separate regulations in parts 868 through 892.
• Guidewire Catheter (FDA Code: DQX / 870.1330)
A catheter guide wire is a coiled wire that is designed to fit inside a percutaneous catheter for the purpose of directing the catheter through a blood vessel.
• Implanted Subcutaneous Intravascular Port & Catheter (FDA Code: LJT / 880.5965)
A subcutaneous, implanted, intravascular infusion port and catheter is a device that consists of a subcutaneous, implanted reservoir that connects to a long-term intravascular catheter. The device allows for repeated access to the vascular system for the infusion of fluids and medications and the sampling of blood. The device consists of a portal body with a resealable septum and outlet made of metal, plastic, or combination of these materials and a long-term intravascular catheter is either preattached to the port or attached to the port at the time of device placement. The device is available in various profiles and sizes and can be of a single or multiple lumen design.
• Intravenous Administration Kit (FDA Code: FPA / 880.5440)
An intravascular administration set is a device used to administer fluids from a container to a patient's vascular system through a needle or catheter inserted into a vein. The device may include the needle or catheter, tubing, a flow regulator, a drip chamber, an infusion line filter, an I.V. set stopcock, fluid delivery tubing, connectors between parts of the set, a side tube with a cap to serve as an injection site, and a hollow spike to penetrate and connect the tubing to an I.V. bag or other infusion fluid container.
• Lead Extraction Devices
• Lead Extraction Devices 140 cm
• Lead Extraction Devices 152cm
• Lead Extraction Devices 54 cm Version
• Lead Extraction Devices 94 cm Version
• Percutaneous Catheterization Vessel Dilator (FDA Code: DRE / 870.1310)
A vessel dilator for percutaneous catheterization is a device which is placed over the guide wire to enlarge the opening in the vessel, and which is then removed before sliding the catheter over the guide wire.
• Peripheral Systems
• Peripherally Inserted Central Catheter, Single Chamber Systems
• Silicone Peripheral Placement
• Single Chamber Systems
• Ultrasonic Transducer (FDA Code: JOP / 870.2880)
An ultrasonic transducer is a device applied to the skin to transmit and receive ultrasonic energy that is used in conjunction with an echocardiograph to provide imaging of cardiovascular structures. This device includes phased arrays and two-dimensional scanning transducers.