Profile: Corpak Medsystems, Inc. is a developer, manufacturer and marketer of medical devices. We specialize in adult and long-term nasogastric feeding tubes. We offer gastrostomy feeding tubes, gastric relief devices and enteral feeding safety devices. We also manufacture and market enteral/vascular access devices used primarily in the acute care setting, hospitals & surgery centers. We provide catheter position locating instrument and accessories, tubes, peritoneal dialysis catheter & various respiratory accessories.
The company was founded in 1979, has ~150 employees. NYSE:CAH (SEC Filings)
28 Products/Services (Click for related suppliers)
|
• Anesthetic Gas Mask (FDA Code: BSJ / 868.5550) An anesthetic gas mask is a device, usually made of conductive rubber, that is positioned over a patient's nose or mouth to direct anesthetic gases to the upper airway. |
• Anesthetic Infusion Pump (FDA Code: FRN / 880.5725) An infusion pump is a device used in a health care facility to pump fluids into a patient in a controlled manner. The device may use a piston pump, a roller pump, or a peristaltic pump and may be powered electrically or mechanically. The device may also operate using a constant force to propel the fluid through a narrow tube which determines the flow rate. The device may include means to detect a fault condition, such as air in, or blockage of, the infusion line and to activate an alarm. |
• Ceiling-Mounted, Surgical Helmet Systems |
• Direct Patient Interface Respiratory Gas Humidifier (FDA Code: BTT / 868.5450) A respiratory gas humidifier is a device that is intended to add moisture to, and sometimes to warm, the breathing gases for administration to a patient. Cascade, gas, heated, and prefilled humidifiers are included in this generic type of device. |
• Endoscope Accessories (FDA Code: KOG) |
• Enteral Infusion Pump (FDA Code: LZH / 880.5725) |
• Feeding Tubes (FDA Code: FPD / 876.5980) A gastrointestinal tube and accessories is a device that consists of flexible or semi-rigid tubing used for instilling fluids into, withdrawing fluids from, splinting, or suppressing bleeding of the alimentary tract. This device may incorporate an integral inflatable balloon for retention or hemostasis. This generic type of device includes the hemostatic bag, irrigation and aspiration catheter (gastric, colonic, etc.), rectal catheter, sterile infant gavage set, gastrointestinal string and tubes to locate internal bleeding, double lumen tube for intestinal decompression or intubation, feeding tube, gastroenterostomy tube, Levine tube, nasogastric tube, single lumen tube with mercury weight balloon for intestinal intubation or decompression, and gastro-urological irrigation tray (for gastrological use). |
• Gas Mask Head Strap (FDA Code: BTK / 868.5560) A gas mask head strap is a device used to hold an anesthetic gas mask in position on a patient's face. |
• Gastrointestinal Tube and Accessories (FDA Code: KNT / 876.5980) |
• Implanted Percutaneous Long-Term Intravascular Catheter Accessory For Catheter Position (FDA Code: OMF / 880.5970) A percutaneous, implanted, long-term intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings, such as luer hubs, and accessories that facilitate the placement of the device. The device allows for repeated access to the vascular system for long-term use of 30 days or more, and it is intended for administration of fluids, medications, and nutrients; the sampling of blood; and monitoring blood pressure and temperature. The device may be constructed of metal, rubber, plastic, composite materials, or any combination of these materials and may be of single or multiple lumen design. |
• Manual Emergency Ventilator/Resuscitator (FDA Code: BTM / 868.5915) A manual emergency ventilator is a device, usually incorporating a bag and valve, intended to provide emergency respiratory support by means of a face mask or a tube inserted into a patient's airway. |
• Non-Rebreathing Oxygen Mask (FDA Code: KGB / 868.5570) A nonrebreathing mask is a device fitting over a patient's face to administer oxygen. It utilizes one-way valves to prevent the patient from rebreathing previously exhaled gases. |
• Non-Rebreathing Valve (FDA Code: CBP / 868.5870) A nonrebreathing valve is a one-way valve that directs breathing gas flow to the patient and vents exhaled gases into the atmosphere. |
• operating Room Equipment, Surgical Helmet Systems |
• Oxygen Masks (FDA Code: BYG / 868.5580) An oxygen mask is a device placed over a patient's nose, mouth, or tracheostomy to administer oxygen or aerosols. |
• Peristaltic Infusion Pump (FDA Code: FRN / 880.5725) |
• Positive End Expiratory Pressure Breathing Attachment (FDA Code: BYE / 868.5965) A positive end expiratory pressure (PEEP) breathing attachment is a device attached to a ventilator that is used to elevate pressure in a patient's lungs above atmospheric pressure at the end of exhalation. |
• Pressure Tubing and Accessories (FDA Code: BYX / 868.5860) Pressure tubing and accessories are flexible or rigid devices intended to deliver pressurized medical gases. |
• Short-Term Less Than 30 Days Therapeutic Intravascular Catheter (FDA Code: FOZ / 880.5200) An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patient's vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or administer fluids intravenously. The device may be constructed of metal, rubber, plastic, or a combination of these materials. |
• Single-Use Peritoneal Dialysis Catheter (FDA Code: FKO / 876.5630) (1) A peritoneal dialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions, and that consists of a peritoneal access device, an administration set for peritoneal dialysis, a source of dialysate, and, in some cases, a water purification mechanism. After the dialysate is instilled into the patient's peritoneal cavity, it is allowed to dwell there so that undesirable substances from the patient's blood pass through the lining membrane of the peritoneal cavity into this dialysate. These substances are then removed when the dialysate is drained from the patient. The peritoneal dialysis system may regulate and monitor the dialysate temperature, volume, and delivery rate together with the time course of each cycle of filling, dwell time, and draining of the peritoneal cavity or manual controls may be used. This generic device includes the semiautomatic and the automatic peritoneal delivery system. |
• Surgical Exhaust Apparatus (FDA Code: FYD / 878.5070) Air-handling apparatus for a surgical operating room is a device intended to produce a directed, nonturbulent flow of air that has been filtered to remove particulate matter and microorganisms to provide an area free of contaminants to reduce the possibility of infection in the patient. |
• Surgical Gowns (FDA Code: FYA / 878.4040) Surgical apparel are devices that are intended to be worn by operating room personnel during surgical procedures to protect both the surgical patient and the operating room personnel from transfer of microorganisms, body fluids, and particulate material. Examples include surgical caps, hoods, masks, gowns, operating room shoes and shoe covers, and isolation masks and gowns. Surgical suits and dresses, commonly known as scrub suits, are excluded. |
• Surgical Helmet (FDA Code: FXZ / 878.4040) |
• Surgical helmet system (SHS) |
• Surgical Helmet Systems |
• Therapeutic Intravascular Catheter (FDA Code: LJS / 880.5970) |
• Tracheobronchial Suction Catheter (FDA Code: BSY / 868.6810) A tracheobronchial suction catheter is a device used to aspirate liquids or semisolids from a patient's upper airway. |
• Y Piece Breathing Circuit (FDA Code: CAI / 868.5240) An anesthesia breathing circuit is a device that is intended to administer medical gases to a patient during anesthesia. It provides both an inhalation and exhalation route and may include a connector, adaptor, and Y-piece. |