Skype

Depuy France S.A.


Address: Z I La Vendue Bp88, Chaumont, France
Phone: +33-(219)-267-8143 | Map/Directions >>
 
 

Profile: Depuy France S.A. specializes in the designing and manufacturing of orthopedic devices. Our products include trauma products, implants and technologies for hips, knees, ankles, shoulders & wrists, modular knee prosthesis, cemented acetabular cups, fixator pins, powered orthopedic instruments and accessories for fixation system.

FDA Registration Number: 9615674
US Agent: Phyllis Piet-hughes / Greatbatch Ltd
Phone: +1-(763)-951-8184  Fax: +1-(619)-498-9405  E-Mail:

35 Products/Services (Click for related suppliers)  
• Bone Fixation Nail (FDA Code: JDS / 888.3030)
Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.
• Bone Fixation Plate (FDA Code: HRS / 888.3030)
• Bone Fixation Screw (FDA Code: HWC / 888.3040)
A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.
• Bone Rasps (FDA Code: HTR / 878.4800)
A manual surgical instrument for general use is a nonpowered, hand-held, or hand-manipulated device, either reusable or disposable, intended to be used in various general surgical procedures. The device includes the applicator, clip applier, biopsy brush, manual dermabrasion brush, scrub brush, cannula, ligature carrier, chisel, clamp, contractor, curette, cutter, dissector, elevator, skin graft expander, file, forceps, gouge, instrument guide, needle guide, hammer, hemostat, amputation hook, ligature passing and knot-tying instrument, knife, blood lancet, mallet, disposable or reusable aspiration and injection needle, disposable or reusable suturing needle, osteotome, pliers, rasp, retainer, retractor, saw, scalpel blade, scalpel handle, one-piece scalpel, snare, spatula, stapler, disposable or reusable stripper, stylet, suturing apparatus for the stomach and intestine, measuring tape, and calipers. A surgical instrument that has specialized uses in a specific medical specialty is classified in separate regulations in parts 868 through 892.
• Cannulated Drill Bit
• Cement Restrictor Hip Prosthesis (FDA Code: JDK / 878.3300)
Surgical mesh is a metallic or polymeric screen intended to be implanted to reinforce soft tissue or bone where weakness exists. Examples of surgical mesh are metallic and polymeric mesh for hernia repair, and acetabular and cement restrictor mesh used during orthopedic surgery.
• Depth Gauge (FDA Code: HTJ / 888.4300)
A depth gauge for clinical use is a measuring device intended for various medical purposes, such as to determine the proper length of screws for fastening the ends of a fractured bone.
• Drill Bit (FDA Code: HTW / 888.4540)
An orthopedic manual surgical instrument is a nonpowered hand-held device intended for medical purposes to manipulate tissue, or for use with other devices in orthopedic surgery. This generic type of device includes the cerclage applier, awl, bender, drill brace, broach, burr, corkscrew, countersink, pin crimper, wire cutter, prosthesis driver, extractor, file, fork, needle holder, impactor, bending or contouring instrument, compression instrument, passer, socket positioner, probe, femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench.
• Drill Bits & Bone Taps
• Flexible Depth Gauge (FDA Code: HTJ / 888.4300)
• General Surgical Manual Instrument (FDA Code: MDM / 878.4800)
• Hip Joint (Hemi- Hip) Acetabular Metal Cemented Prosthesis (FDA Code: KWB / 888.3370)
A hip joint (hemi-hip) acetabular metal cemented prosthesis is a device intended to be implanted to replace a portion of the hip joint. This generic type of device includes prostheses that have an acetabular component made of alloys, such as cobalt-chromium-molybdenum. This generic type of device is limited to those prostheses intended for use with bone cement (888.3027).
• Human Bone Rasps (FDA Code: HTR / 878.4800)
• Intramedullary Bone Rasps
• Intramedullary Fixation Rod and Accessories (FDA Code: HSB / 888.3020)
An intramedullary fixation rod is a device intended to be implanted that consists of a rod made of alloys such as cobalt-chromium-molybdenum and stainless steel. It is inserted into the medullary (bone marrow) canal of long bones for the fixation of fractures.
• Medical Rasps (FDA Code: HTR / 878.4800)
• Metal Cemented Femoral Component Hip Prosthesis (FDA Code: JDG / 888.3360)
A hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis is a device intended to be implanted to replace a portion of the hip joint. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum. This generic type of device includes designs which are intended to be fixed to the bone with bone cement (888.3027) as well as designs which have large window-like holes in the stem of the device and which are intended for use without bone cement. However, in these latter designs, fixation of the device is not achieved by means of bone ingrowth.
• Metal Femoral Hemi- Hip Prosthesis (FDA Code: KWL / 888.3360)
• Metal/Polymer Constrained Finger Prosthesis (FDA Code: KWG / 888.3220)
A finger joint metal/polymer constrained cemented prosthesis is a device intended to be implanted to replace a metacarpophalangeal or proximal interphalangeal (finger) joint. The device prevents dislocation in more than one anatomic plane, and consists of two components which are linked together. This generic type of device includes prostheses that are made of alloys, such as cobalt-chromium-molybdenum, and ultra-high molecular weight polyethylene, and is limited to those prostheses intended for use with bone cement (888.3027).
• Metal/Polymer Femoral Hemi- Hip Prosthesis (FDA Code: KWY / 888.3390)
A hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis is a two-part device intended to be implanted to replace the head and neck of the femur. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and a snap-fit acetabular component made of an alloy, such as cobalt-chromium-molybdenum, and ultra-high molecular weight polyethylene. This generic type of device may be fixed to the bone with bone cement (888.3027) or implanted by impaction.
• Metal/Polymer Semi-Constrained Hip Prosthesis (FDA Code: LPH / 888.3358)
A hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis is a device intended to be implanted to replace a hip joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across the joint. This generic type of device has a femoral component made of a cobalt-chromium-molybdenum (Co-Cr-Mo) alloy or a titanium-aluminum-vanadium (Ti-6Al-4V) alloy and an acetabular component composed of an ultra-high molecular weight polyethylene articulating bearing surface fixed in a metal shell made of Co-Cr-Mo or Ti-6Al-4V. The femoral stem and acetabular shell have a porous coating made of, in the case of Co-Cr-Mo substrates, beads of the same alloy, and in the case of Ti-6Al-4V substrates, fibers of commercially pure titanium or Ti-6Al-4V alloy. The porous coating has a volume porosity between 30 and 70 percent, an average pore size between 100 and 1,000 microns, interconnecting porosity, and a porous coating thickness between 500 and 1,500 microns. The generic type of device has a design to achieve biological fixation to bone without the use of bone cement.
• Multiple Component Fixation Appliance (FDA Code: KTT / 888.3030)
• Nut Bolt Washer (FDA Code: HTN / 888.3030)
• Orthopedic Fixation Accessories (FDA Code: LYT / 888.3030)
• Orthopedic Manual Surgical Instrument (FDA Code: LXH / 888.4540)
• Osteophilic Finish Cemented/Non-porous Cemented Semi-constrained Hip Prosthesis (FDA Code: MAY / 888.3353)
A hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis is a device intended to be implanted to replace a hip joint. This device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. The two-part femoral component consists of a femoral stem made of alloys to be fixed in the intramedullary canal of the femur by impaction with or without use of bone cement. The proximal end of the femoral stem is tapered with a surface that ensures positive locking with the spherical ceramic (aluminium oxide, A1203) head of the femoral component. The acetabular component is made of ultra-high molecular weight polyethylene or ultra-high molecular weight polyethylene reinforced with nonporous metal alloys, and used with or without bone cement.
• Pneumatic Powered Orthopedic Surgical Instrument & Accessory (FDA Code: HSZ / 878.4820)
• Reamer (FDA Code: HTO / 888.4540)
• Semi-Constrained Acetabular Hip Prosthesis (FDA Code: KWA / 888.3330)
A hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis is a two-part device intended to be implanted to replace a hip joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that consist of a femoral and an acetabular component, both made of alloys, such as cobalt-chromium-molybdenum. The femoral component is intended to be fixed with bone cement. The acetabular component is intended for use without bone cement (888.3027).
• Semi-Constrained Patellofemorotibial Knee Prosthesis (FDA Code: JWH / 888.3560)
A knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a knee joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and a tibial component or components and a retropatellar resurfacing component made of ultra-high molecular weight polyethylene. This generic type of device is limited to those prostheses intended for use with bone cement (888.3027).
• Small Depth Gauge (FDA Code: HTJ / 888.4300)
• Smooth Fixation Pin (FDA Code: HTY / 888.3040)
• Surgical Retractor (FDA Code: GAD / 878.4800)
• Surgical Retractor Systems (FDA Code: GAD / 878.4800)
• Threaded Fixation Pin (FDA Code: JDW / 888.3040)

 Edit or Enhance this Company (169 potential buyers viewed listing)
Browse Category   |   Alphabetical Products   |   ALL 25,000 Suppliers
HomeBuyAdd FREE ListingAdvertise Medical CompanyMedical Portal