Profile: Eminent Spine, Llc offers spine technology and cutting edge technology to produce biomedical devices. Our product line comprises of Fang Plate™, Copperhead™, Sidewinder™, Python™ and Cottonmouth™. Our Fang Plate™ provides contours for vessel protections, rational stability, penetrating grooves, tripod fixitations, broad wings span to prevent expulsion and window for graft visualizations. Our Copperhead™, Sidewinder™, Python™ and Cottonmouth™ products have teeth to resist migrations, central opening for maximum bone graft materials, lordosis for allowing insertion & self distraction, and wall thickness to structural supports. These are delivered in three options such as tantalum beads, tantalum pins and with no markers.
10 Products/Services (Click for related suppliers)
|
• Biomedical Devices |
• Cervical Intervertebral Fusion Device With Bone Graft (FDA Code: ODP / 888.3080) |
• Cutting Edge Spinal Implants |
• Lumbar Intervertebral Fusion Device with Bone Graft (FDA Code: MAX / 888.3080) |
• Spinal Implants |
• Spinal Intervertebral Body Fixation Appliance (FDA Code: KWQ / 888.3060) A spinal intervertebral body fixation orthosis is a device intended to be implanted made of titanium. It consists of various vertebral plates that are punched into each of a series of vertebral bodies. An eye-type screw is inserted in a hole in the center of each of the plates. A braided cable is threaded through each eye-type screw. The cable is tightened with a tension device and it is fastened or crimped at each eye-type screw. The device is used to apply force to a series of vertebrae to correct "sway back," scoliosis (lateral curvature of the spine), or other conditions. |
• Spinal Pedicle Fixation Orthosis (FDA Code: MNI / 888.3070) Pedicle screw spinal systems are multiple component devices, made from a variety of materials, including alloys such as 316L stainless steel, 316LVM stainless steel, 22Cr-13Ni-5Mn stainless steel, Ti-6Al-4V, and unalloyed titanium, that allow the surgeon to build an implant system to fit the patient's anatomical and physiological requirements. Such a spinal implant assembly consists of a combination of anchors (e.g., bolts, hooks, and/or screws); interconnection mechanisms incorporating nuts, screws, sleeves, or bolts; longitudinal members (e.g., plates, rods, and/or plate/rod combinations); and/or transverse connectors. |
• Spinal Plates |
• Spinal Vertebral Body Replacement Device (FDA Code: MQP / 888.3060) |