Skype

Endoscopic Technologies, Inc.

Click Here To EMAIL INQUIRY
Contact: Tamer Ibrahim
Web: http://www.estech.com
E-Mail:
Address: 2603 Camino Ramon, Suite 100, San Ramon, California 94583, USA
Phone: +1-(925)-866-7111 | Fax: +1-(925)-866-7117 | Map/Directions >>
 
 

Profile: Endoscopic Technologies, Inc. develops medical devices and disposables that enable cardiac surgeons to perform a variety of traditional and minimally invasive surgical procedures. Our Cobra Adhere XL™ surgical system is a minimally invasive epicardial probe that utilizes ten electrodes to create an easy contiguous box lesion. This Adhere XLT uses advanced suction and internal cooling technology. The suction technology is used to pull the atrial tissue flush to the probe ensuring a consistent and reproducible lesion set. Our Cobra™ surgical probe is a malleable epicardial or endocardial probe that utilizes seven electrodes, which are used to create uniform and reproducible linear lesions. Our COBRA™ bipolar clamps and inserts provide a versatile design that features interchangeable clamps and disposable inserts allowing surgeons the freedom to customize desired lesion shape with optimal ergonomics.

15 Products/Services (Click for related suppliers)  
• Artery Vascular Clamp (FDA Code: DXC / 870.4450)
A vascular clamp is a surgical instrument used to occlude a blood vessel temporarily.
• Bipolar Clamps
• Bipolar Inserts
• Bipolar Pacing Probes
• Cardiopulmonary Bypass Cardiotomy Return Sucker (FDA Code: DTS / 870.4420)
A cardiopulmonary bypass cardiotomy return sucker is a device that consists of tubing, a connector, and a probe or tip that is used to remove blood from the chest or heart during cardiopulmonary bypass surgery.
• Cardiopulmonary Bypass Vascular Catheter (FDA Code: DWF / 870.4210)
A cardiopulmonary bypass vascular catheter, cannula, or tubing is a device used in cardiopulmonary surgery to cannulate the vessels, perfuse the coronary arteries, and to interconnect the catheters and cannulas with an oxygenator. The device includes accessory bypass equipment.
• Cardiovascular Surgical Instrument (FDA Code: DWS / 870.4500)
Cardiovascular surgical instruments are surgical instruments that have special features for use in cardiovascular surgery. These devices include, e.g., forceps, retractors, and scissors.
• Clamps
• Electrosurgical Cutting and Coagulation Device (FDA Code: GEI / 878.4400)
An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.
• Electrosurgical Unit
• Endocardial Probes
• Epicardial Probes
• For Ablation Of Cardiac Tissue Surgical Device (FDA Code: OCL / 878.4400)
• Heart Stabilizer (FDA Code: MWS / 870.4500)
• Vascular Clamps (FDA Code: DXC / 870.4450)

 Edit or Enhance this Company (208 potential buyers viewed listing,  23 forwarded to manufacturer's website)
Browse Category   |   Alphabetical Products   |   ALL 25,000 Suppliers