Profile: Exactech, Inc. is an orthopedic company that develops, manufactures, markets, distributes and sells orthopedic implant devices, related surgical instrumentation & biologic services to hospitals & physicians. Our product list comprises of hip systems, knee systems, bone cement, cement spacers, dental biologics and spine systems. Our AcuMatch® L-Series stems and endoprostheses provide the orthopedic surgeon with several treatment options, including cemented stems, press-fit stems, unipolar endoprosthesis and bipolar endoprosthesis. Its unipolar and bipolar heads are simple to use with one set of instruments. The bipolar design allows for easy assembly with hand pressure. Our Novation® CF™ femoral stems are designed to provide surgeons with excellent initial fixation and long-term stability when paired with the core instruments that support Novation tapered and splined preparation.
The company was founded in 1985, has revenues of USD 50-100 Million, has ~220 employees and is ISO 9001, CE certified. NASDAQ:EXAC (SEC Filings)
FDA Registration Number: 1038671
1 to 50 of 69 Products/Services (Click for related suppliers) Page: [1] 2
|
• AC-Powered Motor Orthopedic Surgical Instrument (FDA Code: HWE / 878.4820) Surgical instrument motors and accessories are AC-powered, battery-powered, or air-powered devices intended for use during surgical procedures to provide power to operate various accessories or attachments to cut hard tissue or bone and soft tissue. Accessories or attachments may include a bur, chisel (osteotome), dermabrasion brush, dermatome, drill bit, hammerhead, pin driver, and saw blade. |
• Allograft Bone Graft |
• Bipolar Endoprosthesis |
• Bone Cement (FDA Code: LOD / 888.3027) Polymethylmethacrylate (PMMA) bone cement is a device intended to be implanted that is made from methylmethacrylate, polymethylmethacrylate, esters of methacrylic acid, or copolymers containing polymethylmethacrylate and polystyrene. The device is intended for use in arthroplastic procedures of the hip, knee, and other joints for the fixation of polymer or metallic prosthetic implants to living bone. |
• Bone Fixation Plate (FDA Code: HRS / 888.3030) Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system. |
• Bone Fixation Screw (FDA Code: HWC / 888.3040) A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system. |
• Bone Graft Harvester |
• Bone Graft Impactor |
• Bone Graft Regeneration Fixation Kit |
• Bone Graft Replacement |
• Bone Graft Screw System |
• Bone Graft Substitute Blocks |
• Bone Graft Substitute Osteotomy Wedges |
• Bone Graft Substitute Plugs |
• Bone Grafting Forceps |
• Bone grafting Osteotomes |
• Bone Grafting Syringe |
• Bone Grafting Wheel |
• Broach (FDA Code: HTQ / 888.4540) An orthopedic manual surgical instrument is a nonpowered hand-held device intended for medical purposes to manipulate tissue, or for use with other devices in orthopedic surgery. This generic type of device includes the cerclage applier, awl, bender, drill brace, broach, burr, corkscrew, countersink, pin crimper, wire cutter, prosthesis driver, extractor, file, fork, needle holder, impactor, bending or contouring instrument, compression instrument, passer, socket positioner, probe, femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. |
• Calcium Compound Bone Void Filler (FDA Code: MQV / 888.3045) A resorbable calcium salt bone void filler device is a resorbable implant intended to fill bony voids or gaps of the extremities, spine, and pelvis that are caused by trauma or surgery and are not intrinsic to the stability of the bony structure. |
• Calicum-Phosphate Non-Porous Metal/Polymer Uncemented Semi-Constrained Hip Prosthesis (FDA Code: MEH / 888.3353) A hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis is a device intended to be implanted to replace a hip joint. This device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. The two-part femoral component consists of a femoral stem made of alloys to be fixed in the intramedullary canal of the femur by impaction with or without use of bone cement. The proximal end of the femoral stem is tapered with a surface that ensures positive locking with the spherical ceramic (aluminium oxide, A1203) head of the femoral component. The acetabular component is made of ultra-high molecular weight polyethylene or ultra-high molecular weight polyethylene reinforced with nonporous metal alloys, and used with or without bone cement. |
• Cement Mixing Equipment (FDA Code: JDZ / 888.4210) A cement mixer for clinical use is a device consisting of a container intended for use in mixing bone cement (888.3027). |
• Cemented Metal/Polymer Semi-Constrained Hip Prosthesis (FDA Code: JDI / 888.3350) A hip joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a hip joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and an acetabular resurfacing component made of ultra-high molecular weight polyethylene and is limited to those prostheses intended for use with bone cement (888.3027). |
• Cemented/Uncemented Semi-constrained Hip Prosthesis (FDA Code: MRA) |
• Compression Instrument (FDA Code: HWN / 888.4540) |
• Depth Gauge (FDA Code: HTJ / 888.4300) A depth gauge for clinical use is a measuring device intended for various medical purposes, such as to determine the proper length of screws for fastening the ends of a fractured bone. |
• Drill Bit (FDA Code: HTW / 888.4540) |
• Drill Brace (FDA Code: HXY / 888.4540) |
• External Knee/Shank/Ankle/Foot Assembly (FDA Code: ISW / 890.3500) An external assembled lower limb prosthesis is a device that is intended for medical purposes and is a preassembled external artificial limb for the lower extremity. Examples of external assembled lower limb prostheses are the following: Knee/shank/ankle/foot assembly and thigh/knee/shank/ankle/foot assembly. |
• Femoral Neck Punch (FDA Code: HWP / 888.4540) |
• Flexible Depth Gauge (FDA Code: HTJ / 888.4300) |
• Fracture Prosthesis |
• Hip Joint Prosthesis |
• Humeral (hemi-shoulder) Metallic Uncemented Prosthesis (FDA Code: HSD / 888.3690) A shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis is a device made of alloys, such as cobalt-chromium-molybdenum. It has an intramedullary stem and is intended to be implanted to replace the articular surface of the proximal end of the humerus and to be fixed without bone cement (888.3027). This device is not intended for biological fixation. |
• Impactor (FDA Code: HWA / 888.4540) |
• Instrument Surgical Guide (FDA Code: FZX / 878.4800) A manual surgical instrument for general use is a nonpowered, hand-held, or hand-manipulated device, either reusable or disposable, intended to be used in various general surgical procedures. The device includes the applicator, clip applier, biopsy brush, manual dermabrasion brush, scrub brush, cannula, ligature carrier, chisel, clamp, contractor, curette, cutter, dissector, elevator, skin graft expander, file, forceps, gouge, instrument guide, needle guide, hammer, hemostat, amputation hook, ligature passing and knot-tying instrument, knife, blood lancet, mallet, disposable or reusable aspiration and injection needle, disposable or reusable suturing needle, osteotome, pliers, rasp, retainer, retractor, saw, scalpel blade, scalpel handle, one-piece scalpel, snare, spatula, stapler, disposable or reusable stripper, stylet, suturing apparatus for the stomach and intestine, measuring tape, and calipers. A surgical instrument that has specialized uses in a specific medical specialty is classified in separate regulations in parts 868 through 892. |
• Metal Cemented Femoral Component Hip Prosthesis (FDA Code: JDG / 888.3360) A hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis is a device intended to be implanted to replace a portion of the hip joint. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum. This generic type of device includes designs which are intended to be fixed to the bone with bone cement (888.3027) as well as designs which have large window-like holes in the stem of the device and which are intended for use without bone cement. However, in these latter designs, fixation of the device is not achieved by means of bone ingrowth. |
• Metal Constrained Hip Prosthesis (FDA Code: KXD / 888.3300) A hip joint metal constrained cemented or uncemented prosthesis is a device intended to be implanted to replace a hip joint. The device prevents dislocation in more than one anatomic plane and has components that are linked together. This generic type of device includes prostheses that have components made of alloys, such as cobalt-chromium-molybdenum, and is intended for use with or without bone cement (888.3027). This device is not intended for biological fixation. |
• Metal Femoral Hemi- Hip Prosthesis (FDA Code: KWL / 888.3360) |
• Metal/Polymer Cemented Non-Constrained Shoulder Prosthesis (FDA Code: KWT / 888.3650) A shoulder joint metal/polymer non-constrained cemented prosthesis is a device intended to be implanted to replace a shoulder joint. The device limits minimally (less than normal anatomic constraints) translation in one or more planes. It has no linkage across-the-joint. This generic type of device includes prostheses that have a humeral component made of alloys, such as cobalt-chromium-molybdenum, and a glenoid resurfacing component made of ultra-high molecular weight polyethylene, and is limited to those prostheses intended for use with bone cement (888.3027). |
• Metal/Polymer Cemented Semi-Constrained Shoulder Prosthesis (FDA Code: KWS / 888.3660) A shoulder joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a shoulder joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that have a humeral resurfacing component made of alloys, such as cobalt-chromium-molybdenum, and a glenoid resurfacing component made of ultra-high molecular weight polyethylene, and is limited to those prostheses intended for use with bone cement (888.3027). |
• Metal/Polymer Constrained Hip Prosthesis (FDA Code: KWZ / 888.3310) A hip joint metal/polymer constrained cemented or uncemented prosthesis is a device intended to be implanted to replace a hip joint. The device prevents dislocation in more than one anatomic plane and has components that are linked together. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and an acetabular component made of ultra-high-molecular-weight polyethylene with or without a metal shell, made of alloys, such as cobalt-chromium-molybdenum and titanium alloys. This generic type of device is intended for use with or without bone cement (888.3027). |
• Metal/Polymer Femoral Hemi- Hip Prosthesis (FDA Code: KWY / 888.3390) A hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis is a two-part device intended to be implanted to replace the head and neck of the femur. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and a snap-fit acetabular component made of an alloy, such as cobalt-chromium-molybdenum, and ultra-high molecular weight polyethylene. This generic type of device may be fixed to the bone with bone cement (888.3027) or implanted by impaction. |
• Metal/Polymer Semi-Constrained Hip Prosthesis (FDA Code: LPH / 888.3358) A hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis is a device intended to be implanted to replace a hip joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across the joint. This generic type of device has a femoral component made of a cobalt-chromium-molybdenum (Co-Cr-Mo) alloy or a titanium-aluminum-vanadium (Ti-6Al-4V) alloy and an acetabular component composed of an ultra-high molecular weight polyethylene articulating bearing surface fixed in a metal shell made of Co-Cr-Mo or Ti-6Al-4V. The femoral stem and acetabular shell have a porous coating made of, in the case of Co-Cr-Mo substrates, beads of the same alloy, and in the case of Ti-6Al-4V substrates, fibers of commercially pure titanium or Ti-6Al-4V alloy. The porous coating has a volume porosity between 30 and 70 percent, an average pore size between 100 and 1,000 microns, interconnecting porosity, and a porous coating thickness between 500 and 1,500 microns. The generic type of device has a design to achieve biological fixation to bone without the use of bone cement. |
• Nail Extractors (FDA Code: HWB / 888.4540) |
• Orthopedic Manual Surgical Instrument (FDA Code: LXH / 888.4540) |
• Osteoinduction Bone Void Filler (FDA Code: MBP / 888.3045) |
• Patellar Implants |
• Primary Femoral Implants |
• Prosthesis Driver (FDA Code: HWR / 888.4540) |