Skype

Flextronics International Gmbh


Contact: Emmanuel Nyakako
Address: Friesacher Strasse 3, Althofen A-9330, Austria
Phone: +43-(978)-2355643 | Map/Directions >>
 
 

Profile: Flextronics International Gmbh focuses on blood lancets.

FDA Registration Number: 3006126537
US Agent: Harry Hari / Flextronics International Inc.
Phone: +1-(949)-274-3429  E-Mail:

1 to 50 of 66 Products/Services (Click for related suppliers)  Page: [1] 2 >> Next 50 Results
• Amniotic Fluid Sampler (FDA Code: HIO / 884.1550)
The amniotic fluid sampler (amniocentesis tray) is a collection of devices used to aspirate amniotic fluid from the amniotic sac via a transabdominal approach. Components of the amniocentesis tray include a disposable 3 inch 20 gauge needle with stylet and a 30 cc. syringe, as well as the various sample collection accessories, such as vials, specimen containers, medium, drapes, etc. The device is used at 16-18 weeks gestation for antepartum diagnosis of certain congenital abnormalities or anytime after 24 weeks gestation when used to assess fetal maturity.
• Analytical Sampling Infusion Pump (FDA Code: LZF / 880.5725)
An infusion pump is a device used in a health care facility to pump fluids into a patient in a controlled manner. The device may use a piston pump, a roller pump, or a peristaltic pump and may be powered electrically or mechanically. The device may also operate using a constant force to propel the fluid through a narrow tube which determines the flow rate. The device may include means to detect a fault condition, such as air in, or blockage of, the infusion line and to activate an alarm.
• Anesthetic Infusion Pump (FDA Code: FRN / 880.5725)
• Arthroscopes (FDA Code: HRX / 888.1100)
An arthroscope is an electrically powered endoscope intended to make visible the interior of a joint. The arthroscope and accessories also is intended to perform surgery within a joint.
• Assayed and Unassayed Single (Specified) Analyte Controls (FDA Code: JJX / 862.1660)
A quality control material (assayed and unassayed) for clinical chemistry is a device intended for medical purposes for use in a test system to estimate test precision and to detect systematic analytical deviations that may arise from reagent or analytical instrument variation. A quality control material (assayed and unassayed) may be used for proficiency testing in interlaboratory surveys. This generic type of device includes controls (assayed and unassayed) for blood gases, electrolytes, enzymes, multianalytes (all kinds), single (specified) analytes, or urinalysis controls.
• Automated Hematocrit Instrument (FDA Code: GKF / 864.5600)
An automated hematocrit instrument is a fully automated or semi-automated device which may or may not be part of a larger system. This device measures the packed red cell volume of a blood sample to distinguish normal from abnormal states, such as anemia and erythrocytosis (an increase in the number of red cells).
• Automatic Carbon-Dioxide Insufflator (FDA Code: FCX / 876.1500)
An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.
• Autotransfusion Apparatus (FDA Code: CAC / 868.5830)
An autotransfusion apparatus is a device used to collect and reinfuse the blood lost by a patient due to surgery or trauma.
• Balloon Inflation Syringe (FDA Code: MAV / 870.1650)
An angiographic injector and syringe is a device that consists of a syringe and a high-pressure injector which are used to inject contrast material into the heart, great vessels, and coronary arteries to study the heart and vessels by x-ray photography.
• Barium Enema with Bag Retention Catheter (FDA Code: FGD / 876.5980)
A gastrointestinal tube and accessories is a device that consists of flexible or semi-rigid tubing used for instilling fluids into, withdrawing fluids from, splinting, or suppressing bleeding of the alimentary tract. This device may incorporate an integral inflatable balloon for retention or hemostasis. This generic type of device includes the hemostatic bag, irrigation and aspiration catheter (gastric, colonic, etc.), rectal catheter, sterile infant gavage set, gastrointestinal string and tubes to locate internal bleeding, double lumen tube for intestinal decompression or intubation, feeding tube, gastroenterostomy tube, Levine tube, nasogastric tube, single lumen tube with mercury weight balloon for intestinal intubation or decompression, and gastro-urological irrigation tray (for gastrological use).
• Biopsy Instruments (FDA Code: KNW / 876.1075)
A gastroenterology-urology biopsy instrument is a device used to remove, by cutting or aspiration, a specimen of tissue for microscopic examination. This generic type of device includes the biopsy punch, gastrointestinal mechanical biopsy instrument, suction biopsy instrument, gastro-urology biopsy needle and needle set, and nonelectric biopsy forceps. This section does not apply to biopsy instruments that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.
• Biopsy Instruments (FDA Code: KNW / 876.1075)
• Blood Collection Lancet (FDA Code: FMK / 878.4800)
A manual surgical instrument for general use is a nonpowered, hand-held, or hand-manipulated device, either reusable or disposable, intended to be used in various general surgical procedures. The device includes the applicator, clip applier, biopsy brush, manual dermabrasion brush, scrub brush, cannula, ligature carrier, chisel, clamp, contractor, curette, cutter, dissector, elevator, skin graft expander, file, forceps, gouge, instrument guide, needle guide, hammer, hemostat, amputation hook, ligature passing and knot-tying instrument, knife, blood lancet, mallet, disposable or reusable aspiration and injection needle, disposable or reusable suturing needle, osteotome, pliers, rasp, retainer, retractor, saw, scalpel blade, scalpel handle, one-piece scalpel, snare, spatula, stapler, disposable or reusable stripper, stylet, suturing apparatus for the stomach and intestine, measuring tape, and calipers. A surgical instrument that has specialized uses in a specific medical specialty is classified in separate regulations in parts 868 through 892.
• Blood Gas and Ph Electrode Measurement (FDA Code: CHL / 862.1120)
A blood gases (PCO2, PO2) and blood pH test system is a device intended to measure certain gases in blood, serum, plasma or pH of blood, serum, and plasma. Measurements of blood gases (PCO2, PO2) and blood pH are used in the diagnosis and treatment of life-threatening acid-base disturbances.
• Calcium Ion Specific Electrode (FDA Code: JFP / 862.1145)
A calcium test system is a device intended to measure the total calcium level in serum. Calcium measurements are used in the diagnosis and treatment of parathyroid disease, a variety of bone diseases, chronic renal disease and tetany (intermittent muscular contractions or spasms).
• Catheter Introducers (FDA Code: DYB / 870.1340)
A catheter introducer is a sheath used to facilitate placing a catheter through the skin into a vein or artery.
• Catheter Stylets (FDA Code: DRB / 870.1380)
A catheter stylet is a wire that is run through a catheter or cannula to render it stiff.
• Chloride Ion Specific Electrode (FDA Code: CGZ / 862.1170)
A chloride test system is a device intended to measure the level of chloride in plasma, serum, sweat, and urine. Chloride measurements are used in the diagnosis and treatment of electrolyte and metabolic disorders such as cystic fibrosis and diabetic acidosis.
• Continuous Ventilator (FDA Code: CBK / 868.5895)
A continuous ventilator (respirator) is a device intended to mechanically control or assist patient breathing by delivering a predetermined percentage of oxygen in the breathing gas. Adult, pediatric, and neonatal ventilators are included in this generic type of device.
• Cryosurgical Unit (FDA Code: GEH / 878.4350)
• Diagnostic Biliary Catheter (FDA Code: FGE / 876.5010)
A biliary catheter and accessories is a tubular flexible device used for temporary or prolonged drainage of the biliary tract, for splinting of the bile duct during healing, or for preventing stricture of the bile duct. This generic type of device may include a bile collecting bag that is attached to the biliary catheter by a connector and fastened to the patient with a strap.
• Diagnostic Intravascular Catheter (FDA Code: DQO / 870.1200)
An intravascular diagnostic catheter is a device used to record intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among others.
• Diagnostic Ultrasonic Transducer (FDA Code: ITX / 892.1570)
A diagnostic ultrasonic transducer is a device made of a piezoelectric material that converts electrical signals into acoustic signals and acoustic signals into electrical signals and intended for use in diagnostic ultrasonic medical devices. Accessories of this generic type of device may include transmission media for acoustically coupling the transducer to the body surface, such as acoustic gel, paste, or a flexible fluid container.
• Discrete Photometric Chemistry Analyzer (FDA Code: JJE / 862.2160)
A discrete photometric chemistry analyzer for clinical use is a device intended to duplicate manual analytical procedures by performing automatically various steps such as pipetting, preparing filtrates, heating, and measuring color intensity. This device is intended for use in conjunction with certain materials to measure a variety of analytes. Different models of the device incorporate various instrumentation such as micro analysis apparatus, double beam, single, or dual channel photometers, and bichromatic 2-wavelength photometers. Some models of the device may include reagent-containing components that may also serve as reaction units.
• Endoscope Accessories (FDA Code: KOG)
• Enteral Infusion Pump (FDA Code: LZH / 880.5725)
• Fluid Delivery Tubing (FDA Code: FPK / 880.5440)
An intravascular administration set is a device used to administer fluids from a container to a patient's vascular system through a needle or catheter inserted into a vein. The device may include the needle or catheter, tubing, a flow regulator, a drip chamber, an infusion line filter, an I.V. set stopcock, fluid delivery tubing, connectors between parts of the set, a side tube with a cap to serve as an injection site, and a hollow spike to penetrate and connect the tubing to an I.V. bag or other infusion fluid container.
• Gastro-Urology Catheter & Accessories (FDA Code: KNY / 876.5130)
A urological catheter and accessories is a flexible tubular device that is inserted through the urethra and used to pass fluids to or from the urinary tract. This generic type of device includes radiopaque urological catheters, ureteral catheters, urethral catheters, coudecatheters, balloon retention type catheters, straight catheters, upper urinary tract catheters, double lumen female urethrographic catheters, disposable ureteral catheters, male urethrographic catheters, and urological catheter accessories including ureteral catheter stylets, ureteral catheter adapters, ureteral catheter holders, ureteral catheter stylets, ureteral catheterization trays, and the gastro-urological irrigation tray (for urological use).
• General & Plastic Surgery Laparoscope (FDA Code: GCJ / 876.1500)
• Glucose Glucose Dehydrogenase (FDA Code: LFR / 862.1345)
A glucose test system is a device intended to measure glucose quantitatively in blood and other body fluids. Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus, neonatal hypoglycemia, and idiopathic hypoglycemia, and of pancreatic islet cell carcinoma.
• Glucose Oxidase, Glucose (FDA Code: CGA / 862.1345)
• Guidewire Catheter (FDA Code: DQX / 870.1330)
A catheter guide wire is a coiled wire that is designed to fit inside a percutaneous catheter for the purpose of directing the catheter through a blood vessel.
• Hematocrit Measuring Device (FDA Code: JPI / 864.6400)
A hematocrit measuring device is a system consisting of instruments, tubes, racks, and a sealer and a holder. The device is used to measure the packed red cell volume in blood to determine whether the patient's total red cell volume is normal or abnormal. Abnormal states include anemia (an abnormally low total red cell volume) and erythrocytosis (an abnormally high total red cell mass). The packed red cell volume is produced by centrifuging a given volume of blood.
• High Pressure Liquid Chromatography Instrumentation (FDA Code: LDM / 862.2260)
A high pressure liquid chromatography system for clinical use is a device intended to separate one or more drugs or compounds from a solution by processing the mixture of compounds (solutes) through a column packed with materials of uniform size (stationary phase) under the influence of a high pressure liquid (mobile phase). Separation of the solutes occurs either by absorption, sieving, partition, or selective affinity.
• I.V. Fluid Transfer Unit (FDA Code: LHI / 880.5440)
• Instrumentation For Clinical Multiplex Test Systems (FDA Code: NSU / 862.2570)
• Insulin Infusion Pump (FDA Code: LZG / 880.5725)
• Interactive Wound and Burn Dressing (FDA Code: MGR)
• Intravenous Administration Kit (FDA Code: FPA / 880.5440)
• Multi Analyte Control (FDA Code: JJY / 862.1660)
• Multi Analyte Mixture - Calibrator (FDA Code: JIX / 862.1150)
A calibrator is a device intended for medical purposes for use in a test system to establish points of reference that are used in the determination of values in the measurement of substances in human specimens. (See also 862.2 in this part.)
• Negative Pressure Wound Therapy Powered Suction Pump (FDA Code: OMP / 878.4780)
A powered suction pump is a portable, AC-powered or compressed air-powered device intended to be used to remove infectious materials from wounds or fluids from a patient's airway or respiratory support system. The device may be used during surgery in the operating room or at the patient's bedside. The device may include a microbial filter.
• Non-Electromagnetic Radiation Blood Warmer (FDA Code: BSB / 864.9205)
A nonelectromagnetic blood and plasma warming device is a device that warms blood or plasma, by means other than electromagnetic radiation, prior to administration.
• Over-The-Counter Blood Glucose Test System (FDA Code: NBW / 862.1345)
• Patient Lubricant (FDA Code: KMJ / 880.6375)
A patient lubricant is a device intended for medical purposes that is used to lubricate a body orifice to facilitate entry of a diagnostic or therapeutic device.
• Percutaneous Catheter (FDA Code: DQY / 870.1250)
A percutaneous catheter is a device that is introduced into a vein or artery through the skin using a dilator and a sheath (introducer) or guide wire.
• Peristaltic Infusion Pump (FDA Code: FRN / 880.5725)
• Phacofragmentation Unit (FDA Code: HQC / 886.4670)
A phacofragmentation system is an AC-powered device with a fragmenting needle intended for use in cataract surgery to disrupt a cataract with ultrasound and extract the cataract.
• Polymeric Surgical Mesh (FDA Code: FTL / 878.3300)
Surgical mesh is a metallic or polymeric screen intended to be implanted to reinforce soft tissue or bone where weakness exists. Examples of surgical mesh are metallic and polymeric mesh for hernia repair, and acetabular and cement restrictor mesh used during orthopedic surgery.
• Positive End Expiratory Pressure Breathing Attachment (FDA Code: BYE / 868.5965)
A positive end expiratory pressure (PEEP) breathing attachment is a device attached to a ventilator that is used to elevate pressure in a patient's lungs above atmospheric pressure at the end of exhalation.

 Edit or Enhance this Company (681 potential buyers viewed listing)
Browse Category   |   Alphabetical Products   |   ALL 25,000 Suppliers
HomeBuyAdd FREE ListingAdvertise Medical CompanyMedical Portal