Skype

Fusion Posterior Metal/Polymer Spinal System Suppliers

Limit companies to: Worldwide  USA  
 EMAIL INQUIRY to  8 suppliers  
Medtronic Xomed Surgical Products, Inc | Address: 6743 Southpoint Drive North, Jacksonville, Florida 32216-0980, USA USA
www.xomed.com | Phone: +1-(904)-296-9600, 800-874-5797
FDA Registration: 1045254  Year Established: 1999  Annual Revenues: USD 500 Million to 1 Billion  Employee Count: ~650  Quality: ISO 9001, CE Certified
Products: Sinus Trochars and Cannulae, Surgical Navigation Interface/Display, Nerve Stimulators, Eyeshields, General Diagnostic Supplies, General Surgical Aids, ...
Medtronic Xomed Surgical Products, Inc develops products that treat people with ear, nose and throat (ENT) diseases. our products include MeroPack®, Bioresorbable Nasal Dressing and Sinus Stent, I more...
 
Globus Medical, Inc. | Address: 2560 General Armistead Avenue, Audubon, Pennsylvania 19403, USA USA
www.globusmedical.com | Send Inquiry | Phone: +1-(610)-415-9000
FDA Registration: 3004142400
Products: Plating Systems, Spinal Plates, Anterior Cervical Fusion Kit, Spinal Products, Anterior Cervical Plate, Cervical Plate System, ...
Globus Medical, Inc. offers a complete suite of spinal products including fusion, MIS (minimally invasive surgery), motion preservation and biomaterials. Our portfolio includes a full line of technolo more...
Alphatec Spine, Inc. | Address: 5818 El Camino Real, Carlsbad, California 92008, USA USA
www.alphatecspine.com | Send Inquiry | Phone: +1-(760)-431-9286, 800-922-1356
FDA Registration: 2027467
Products: Anterior Cervical Plating System, Disposable Aspiration and Injection Needle (FDA Code: GAA), Bone Fixation Nail (FDA Code: JDS), Bone Fixation Plate (FDA Code: HRS), Bone Fixation Screw (FDA Code: HWC), Cervical Intervertebral Fusion Device With Bone Graft (FDA Code: ODP), ...
Alphatec Spine, Inc. is a medical device company that designs, develops, manufactures and markets products for the surgical treatment of spine disorders, primarily focused on the aging spine. We have more...
Synthes (USA) | Address: 35 Airport Road, Horseheads, New York 14845, USA USA
www.synthes.com/html | Send Inquiry | Phone: +1-(610)-719-5000
FDA Registration: 3003506883  Year Established: 1974  Annual Revenues: > USD 1 Billion  Employee Count: ~9000
Products: Bone Taps (FDA Code: HWX), Stainless Steel Surgical Wire, Drill Bits & Bone Taps, Surgical Wire (FDA Code: LRN), Burr Hole Cover (FDA Code: GXR), Bone Fixation Plate (FDA Code: HRS), ...
Synthes (USA) is a medical device company. We develop, produce and market instruments, implants & biomaterials for the surgical fixation, correction and regeneration of the human skeleton & its soft t more...
Paradigm Spine, Llc | Address: 505 Park Ave, 14th Floor, New York, New York 10022, USA USA
www.paradigmspine.com | Send Inquiry | Phone: +1-(212)-583-9700
FDA Registration: 3005725110
Products: Spinal Implants, Spinal Pedicle Fixation Orthosis (FDA Code: MNI), Spondylolisthesis Spinal Fixation Orthosis (FDA Code: MNH), Spinal Pedicle Fixation Orthosis For Degenerative Disc Disease (FDA Code: NKB), Fusion Posterior Metal/Polymer Spinal System (FDA Code: NQP), Interspinous Implants, ...
Paradigm Spine, Llc is a provider of non-fusion spinal implant solutions. We offer Coflex™, an implant used in the treatment of facet arthrosis and de-compressive procedures. Our products are us more...
Integrant - Medical Device Company Australia | Address: 2/5 Knox St., Double Bay 2028, Australia
https://integrant.com.au | Send Inquiry | Phone: +61-(02)-9363 8823
Products: Flat Back Spinal Fusion Curette, FRS/Fusion and Reconstruction System, General Purpose Electrosurgical Equipment, Fusion and Stereoscopic Target (FDA Code: HLP), Fusion Posterior Metal/Polymer Spinal System (FDA Code: NQP), Cryosurgical Equipments, ...
Integrant - Medical Device Company Australia specializes in providing medical device company. Our products include subtalar arthroereisis implants, and surgical fusion aids. FuseIt device removes the more...
Spineart Sa | Address: 20 Route De Pre Bois, Cp 1813, Geneva 1215, Switzerland
www.spineart.ch | Send Inquiry | Phone: +41-(22)-7994020
FDA Registration: 3007728266
Products: Disc Prosthesis, Intersomatic Lumbar Cages, Interspinous Process Distraction Device, Spinal Fixation Device, Lumbar Intervertebral Fusion Device with Bone Graft (FDA Code: MAX), Fusion Posterior Metal/Polymer Spinal System (FDA Code: NQP), ...
Spineart Sa designs and markets spine patented implants. We provide Baguera® C which is a cervical disc prosthesis that is pre-assembled, & MRI-compatible. Tryptik® CA cervical & Juliet® l more...
Zimmer Gmbh | Address: Sulzer Allee 8, Winterthur CH-8404, Switzerland
FDA Registration: 9613350
Products: Small Depth Gauge (FDA Code: HTJ), Depth Gauge (FDA Code: HTJ), Flexible Depth Gauge (FDA Code: HTJ), Uncemented Metal/Polymer Semi-Constrained Hip Prosthesis (FDA Code: LWJ), Cemented Metal/Polymer Semi-Constrained Hip Prosthesis (FDA Code: JDI), Uncemented, Cemented Or Non-Porous Metal/Ceramic/Polymer Semi-Constrained Hip Prosthesis (FDA Code: LZO), ...
Zimmer Gmbh designs and manufactures reconstructive spinal and dental implants, trauma and related orthopedic surgical products. We also offer joint replacement solutions for knee pain and hip pain, a more...
 EMAIL INQUIRY to  8 Fusion Posterior Metal/Polymer Spinal System suppliers  
FDA Code / Regulation: NQP / 888.3070

Pedicle screw spinal systems are multiple component devices, made from a variety of materials, including alloys such as 316L stainless steel, 316LVM stainless steel, 22Cr-13Ni-5Mn stainless steel, Ti-6Al-4V, and unalloyed titanium, that allow the surgeon to build an implant system to fit the patient's anatomical and physiological requirements. Such a spinal implant assembly consists of a combination of anchors (e.g., bolts, hooks, and/or screws); interconnection mechanisms incorporating nuts, screws, sleeves, or bolts; longitudinal members (e.g., plates, rods, and/or plate/rod combinations); and/or transverse connectors.

Classification. (1) Class II (special controls), when intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: severe spondylolisthesis (grades 3 and 4) of the L5-S1 vertebra; degenerative spondylolisthesis with objective evidence of neurologic impairment; fracture; dislocation; scoliosis; kyphosis; spinal tumor; and failed previous fusion (pseudarthrosis). These pedicle screw spinal systems must comply with the following special controls:

 BROWSE BY CATEGORY > Orthopedics/Physical Therapy OR VIEW PRODUCTS UNDER Orthopedics/Physical Therapy
Browse Category   |   Alphabetical Products   |   ALL 25,000 Suppliers
HomeBuyAdd FREE ListingAdvertise Medical CompanyMedical Portal