Profile: Genicon deals with the design, production, and distribution of patented surgical instrumentation focused exclusively on laparoscopic surgery. Our product line includes several families of laparoscopic devices such as medical video systems, trocar cannula systems, lavage products, mono-polar and bi-polar instrumentation. Our bladeless tip trocar system provides a versatile, operationally flexible mode of entry into the abdominal cavity for any laparoscopic procedure. The distinctively engineered visual tip greatly reduces wound defect size as well as insertion force into the abdominal cavity. It eliminates injuries due to blind entry and a sharp blade. Our disposable specimen retrieval bag is an easy-to-use retrieval system designed to temporarily contain specimen and facilitate its removal from the patient during laparoscopic surgery. It is designed to minimize contamination of the abdominal cavity.
The company was founded in 1998, has revenues of USD 1-5 Million, has ~20 employees and is ISO 13485:2003 certified.
FDA Registration Number: 1064003
15 Products/Services (Click for related suppliers)
|
• Articulating Dissectors |
• Bladeless Trocars |
• Electrosurgical Cutting and Coagulation Device (FDA Code: GEI / 878.4400) An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current. |
• General & Plastic Surgery Laparoscope (FDA Code: GCJ / 876.1500) An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations. |
• General & Plastic Surgery Surgical Cannula (FDA Code: GEA / 878.4800) A manual surgical instrument for general use is a nonpowered, hand-held, or hand-manipulated device, either reusable or disposable, intended to be used in various general surgical procedures. The device includes the applicator, clip applier, biopsy brush, manual dermabrasion brush, scrub brush, cannula, ligature carrier, chisel, clamp, contractor, curette, cutter, dissector, elevator, skin graft expander, file, forceps, gouge, instrument guide, needle guide, hammer, hemostat, amputation hook, ligature passing and knot-tying instrument, knife, blood lancet, mallet, disposable or reusable aspiration and injection needle, disposable or reusable suturing needle, osteotome, pliers, rasp, retainer, retractor, saw, scalpel blade, scalpel handle, one-piece scalpel, snare, spatula, stapler, disposable or reusable stripper, stylet, suturing apparatus for the stomach and intestine, measuring tape, and calipers. A surgical instrument that has specialized uses in a specific medical specialty is classified in separate regulations in parts 868 through 892. |
• Graspers |
• Implantable Clip (FDA Code: FZP / 878.4300) An implantable clip is a clip-like device intended to connect internal tissues to aid healing. It is not absorbable. |
• Laparoscopic Insufflator (FDA Code: HIF / 884.1730) A laparoscopic insufflator is a device used to facilitate the use of the laparoscope by filling the peritoneal cavity with gas to distend it. |
• Laparoscopic Suction/Irrigation Equipment |
• Lavage Unit |
• Specimen Retrieval Bags |
• Sterile Specimen Container (FDA Code: FMH / 864.3250) A specimen transport and storage container, which may be empty or prefilled, is a device intended to contain biological specimens, body waste, or body exudate during storage and transport in order that the matter contained therein can be destroyed or used effectively for diagnostic examination. If prefilled, the device contains a fixative solution or other general purpose reagent to preserve the condition of a biological specimen added to the container. This section does not apply to specimen transport and storage containers that are intended for use as part of an over-the-counter test sample collection system for drugs of abuse testing. |
• Sterilization Tray |
• Straight Scissors |
• Xenon Arc Endoscope Light Source (FDA Code: GCT / 876.1500) |