Skype

Genzyme Corporation

Click Here To EMAIL INQUIRY
Web: http://www.genzyme.com
E-Mail:
Address: 500 Kendall St., Cambridge, Massachusetts 02142, USA
Phone: +001-(252)-252 7500 | Fax: +001-(252)-252 7600 | Map/Directions >>
 
 

Profile: Genzyme Corporation produces & sells synthetically challenging chemicals, biochemicals, clinical chemistry reagents & point-of-care test kits. We offer a complete range of general and specialty clinical chemistry reagents, along with supporting calibrators and controls. Our point of care rapid test kits include OSOM BVBlue test, card pregnancy, HCG urine, influenza AB, mono, sterp A and trichomonas rapid test. Our OSOM® BVBLUE® test detects elevated vaginal fluid sialidase activity, an enzyme produced by bacterial pathogens associated with bacterial vaginosis including gardnerella, bacteroides, prevotella & mobilincus. We have introduced L3K® technology, a patented platform technology that allows us to deliver a single vial, stable liquid reagent with exceptional on-board and calibration stability. Our first product using L3K® technology is a single-vial, stable liquid C02 reagent.

The company was founded in 1970, has revenues of USD 10-25 Million, has ~20 employees and is ISO 9001 certified.

FDA Registration Number: 1220423

1 to 50 of 56 Products/Services (Click for related suppliers)  Page: [1] 2 >> Next 50 Results
• Acetaminophen Colorimetry Test (FDA Code: LDP / 862.3030)
An acetaminophen test system is a device intended to measure acetaminophen, an analgestic and fever reducing drug, in serum. Measurements obtained by this device are used in the diagnosis and treatment of acetaminophen overdose.
• Acid, Hydroxyazobenzene-Benzoic, Albumin (FDA Code: CJZ / 862.1035)
An albumin test system is a device intended to measure the albumin concentration in serum and plasma. Albumin measurements are used in the diagnosis and treatment of numerous diseases involving primarily the liver or kidneys.
• Alkaline Phosphatase (ALP) (FDA Code: JCJ / 864.7660)
A leukocyte alkaline phosphatase test is a device used to identify the enzyme leukocyte alkaline phosphatase in neutrophilic granulocytes (granular leukocytes stainable by neutral dyes). The cytochemical identification of alkaline phosphatase depends on the formation of blue granules in cells containing alkaline phosphatase. The results of this test are used to differentiate chronic granulocytic leukemia (a malignant disease characterized by excessive overgrowth of granulocytes in the bone marrow) and reactions that resemble true leukemia, such as those occuring in severe infections and polycythemia (increased total red cell mass).
• Alkaline Picrate Creatinine Colorimetric Method (FDA Code: CGX / 862.1225)
A creatinine test system is a device intended to measure creatinine levels in plasma and urine. Creatinine measurements are used in the diagnosis and treatment of renal diseases, in monitoring renal dialysis, and as a calculation basis for measuring other urine analytes.
• Ammonia Enzymatic Method Test (FDA Code: JIF / 862.1065)
An ammonia test system is a device intended to measure ammonia levels in blood, serum, and plasma, Ammonia measurements are used in the diagnosis and treatment of severe liver disorders, such as cirrhosis, hepatitis, and Reye's syndrome.
• Amylase Catalytic Method Test (FDA Code: JFJ / 862.1070)
An amylase test system is a device intended to measure the activity of the enzyme amylase in serum and urine. Amylase measurements are used primarily for the diagnosis and treatment of pancreatitis (inflammation of the pancreas).
• Automated Chemiluminescent Immunoassay Analyzers
• Automated Enzyme Immunoassay Analyzers
• Automated Immunoassay Analyzers
• Bile Acids Cholyglycine Radioimmunoassay (FDA Code: KWW / 862.1177)
A cholylglycine test system is a device intended to measure the bile acid cholylglycine in serum. Measurements obtained by this device are used in the diagnosis and treatment of liver disorders, such as cirrhosis or obstructive liver disease.
• Bilirubin Diazo Colorimetry Test (FDA Code: CIG / 862.1110)
A bilirubin (total or direct) test system is a device intended to measure the levels of bilirubin (total or direct) in plasma or serum. Measurements of the levels of bilirubin, an organic compound formed during the normal and abnormal distruction of red blood cells, if used in the diagnosis and treatment of liver, hemolytic hematological, and metabolic disorders, including hepatitis and gall bladder block.
• Blood Analyzer Reagents
• Blood Urea Nitrogen (BUN) Reagent
• Carbon-Dioxide Enzymatic (FDA Code: KHS / 862.1160)
A bicarbonate/carbon dioxide test system is a device intended to measure bicarbonate/carbon dioxide in plasma, serum, and whole blood. Bicarbonate/carbon dioxide measurements are used in the diagnosis and treatment of numerous potentially serious disorders associated with changes in body acid-base balance.
• Chloride Test System (FDA Code: CHJ / 862.1170)
A chloride test system is a device intended to measure the level of chloride in plasma, serum, sweat, and urine. Chloride measurements are used in the diagnosis and treatment of electrolyte and metabolic disorders such as cystic fibrosis and diabetic acidosis.
• Cholesterol Colorimetric Test (FDA Code: CGO / 862.1175)
A cholesterol (total) test system is a device intended to measure cholesterol in plasma and serum. Cholesterol measurements are used in the diagnosis and treatment of disorders involving excess cholesterol in the blood and lipid and lipoprotein metabolism disorders.
• Clinical Chemistry and Immunoassay Analyzers
• Clinical Diagnostic Solutions, Hematology Reagents
• Colorimetric Uric Acid Test (FDA Code: KNK / 862.1775)
A uric acid test system is a device intended to measure uric acid in serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment of numerous renal and metabolic disorders, including renal failure, gout, leukemia, psoriasis, starvation or other wasting conditions, and of patients receiving cytotoxic drugs.
• Creatine Phosphate Kinase Reagent Test
• Cytochemical, Acid Phosphatase (FDA Code: JCI / 864.1850)
Dye and chemical solution stains for medical purposes are mixtures of synthetic or natural dyes or nondye chemicals in solutions used in staining cells and tissues for diagnostic histopathology, cytopathology, or hematology.
• Determination Of Alkaline Phosphatase
• Diazo AST/SGOT (FDA Code: CIQ / 862.1100)
An aspartate amino transferase (AST/SGOT) test system is a device intended to measure the activity of the enzyme aspartate amino transferase (AST) (also known as a serum glutamic oxaloacetic transferase or SGOT) in serum and plasma. Aspartate amino transferase measurements are used in the diagnosis and treatment of certain types of liver and heart disease.
• Enzymatic Esterase-Oxidase, Cholesterol (FDA Code: CHH / 862.1175)
• Ethyl Alcohol Test (FDA Code: DMJ / 862.3040)
An alcohol test system is a device intented to measure alcohol (e.g., ethanol, methanol, isopropanol, etc.) in human body fluids (e.g., serum, whole blood, and urine). Measurements obtained by this device are used in the diagnosis and treatment of alcohol intoxication and poisoning.
• Ferrozine Iron Binding Capacity Test (FDA Code: JMO / 862.1415)
An iron-binding capacity test system is a device intended to measure iron-binding capacity in serum. Iron-binding capacity measurements are used in the diagnosis and treatment of anemia.
• Fluorometric Calcium (FDA Code: JFO / 862.1145)
A calcium test system is a device intended to measure the total calcium level in serum. Calcium measurements are used in the diagnosis and treatment of parathyroid disease, a variety of bone diseases, chronic renal disease and tetany (intermittent muscular contractions or spasms).
• Gamma-Glutamyl Transpeptidase Colorimetric Method (FDA Code: JPZ / 862.1360)
A gamma-glutamyl transpeptidase and isoenzymes test system is a device intended to measure the activity of the enzyme gamma-glutamyl transpeptidase (GGTP) in plasma and serum. Gamma-glutamyl transpeptidase and isoenzymes measurements are used in the diagnosis and treatment of liver diseases such as alcoholic cirrhosis and primary and secondary liver tumors.
• Glucose Hexokinase Test (FDA Code: CFR / 862.1345)
A glucose test system is a device intended to measure glucose quantitatively in blood and other body fluids. Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus, neonatal hypoglycemia, and idiopathic hypoglycemia, and of pancreatic islet cell carcinoma.
• Glucose Oxidase, Glucose (FDA Code: CGA / 862.1345)
• Haematology and Immunoassay Analyzers
• HDL Precipitation Method (FDA Code: LBR / 862.1475)
A lipoprotein test system is a device intended to measure lipoprotein in serum and plasma. Lipoprotein measurements are used in the diagnosis and treatment of lipid disorders (such as diabetes mellitus), atherosclerosis, and various liver and renal diseases.
• Hematology Reagents
• Hematology Reagents and Kits
• Hematology Reagents and Kits Hemoglobin A1C (Glycohemoglobin)
• Hematology Reagents and Supplies
• Immunoassay Analyzers
• Inorganic Phosphorus Phosphomolybdate (FDA Code: CEO / 862.1580)
A phosphorus (inorganic) test system is a device intended to measure inorganic phosphorus in serum, plasma, and urine. Measurements of phosphorus (inorganic) are used in the diagnosis and treatment of various disorders, including parathyroid gland and kidney diseases, and vitamin D imbalance.
• Iron Reagent (FDA Code: CFM / 862.1410)
An iron (non-heme) test system is a device intended to measure iron (non-heme) in serum and plasma. Iron (non-heme) measurements are used in the diagnosis and treatment of diseases such as iron deficiency anemia, hemochromatosis (a disease associated with widespread deposit in the tissues of two iron-containing pigments, hemosiderin and hemofuscin, and characterized by pigmentation of the skin), and chronic renal disease.
• Lactate Dehydrogenase 4-dinitrophenylhydrazine 2 (FDA Code: CER / 862.1440)
A lactate dehydrogenase test system is a device intended to measure the activity of the enzyme lactate dehydrogenase in serum. Lactate dehydrogenase measurements are used in the diagnosis and treatment of liver diseases such as acute viral hepatitis, cirrhosis, and metastatic carcinoma of the liver, cardiac diseases such as myocardial infarction, and tumors of the lung or kidneys.
• LDL & VLDL Precipitation Method (FDA Code: LBR / 862.1475)
• Lipoproteins HDL Via LDL & VLDL Precipitation
• Magnesium Photometric Method Test (FDA Code: JGJ / 862.1495)
A magnesium test system is a device intended to measure magnesium levels in serum and plasma. Magnesium measurements are used in the diagnosis and treatment of hypomagnesemia (abnormally low plasma levels of magnesium) and hypermagnesemia (abnormally high plasma levels of magnesium).
• Microalbumin Urine Test Kits
• Mouse Anti-Human Prostatic Acid Phosphatase (PSAP) Detection Kit
• Nadh Oxidation/Nad Reduction (FDA Code: CKA / 862.1030)
An alanine amino transferase (ALT/SGPT) test system is a device intended to measure the activity of the enzyme alanine amino transferase (ALT) (also known as a serum glutamic pyruvic transaminase or SGPT) in serum and plasma. Alanine amino transferase measurements are used in the diagnosis and treatment of certain liver diseases (e.g., viral hepatitis and cirrhosis) and heart diseases.
• PAP Prostatic Acid Phosphatase (ELISA Kits)
• Prostatic Acid Phosphatase
• Radioimmunoassay Kit For Prostatic Acid Phosphatase
• Rapid Test Kits, Test Kit

 Edit or Enhance this Company (903 potential buyers viewed listing,  116 forwarded to manufacturer's website)
Browse Category   |   Alphabetical Products   |   ALL 25,000 Suppliers
HomeBuyAdd FREE ListingAdvertise Medical CompanyMedical Portal