Skype
 Culture Media Supplements Suppliers > Howmedica International Ltd

Howmedica International Ltd


Contact: Dave Smith - Sales Manager
Address: 622 Western Avenue, Park Royal, London W3 0TF, United Kingdom
Phone: +44-(181)-992-8044 | Fax: +44-(181)-992-0634 | Map/Directions >>
 
 

Profile: Howmedica International Ltd specializes in offering orthopedic products. Our products include bone fixation plate, bone drills, femoral prosthetic implants, foot prosthesis, human bone rasps, nail extractors, orthopedic cement and surgical curette.

The company has ~150 employees and is ISO 9002, CE certified. NYSE:PFE (SEC Filings)

51 to 100 of 129 Products/Services (Click for related suppliers)  Page: << Previous 50 Results 1 [2] 3 >> Next 50 Results
• Flat Foot Prosthesis Fragment Sets
• Flexible Depth Gauge (FDA Code: HTJ / 888.4300)
A depth gauge for clinical use is a measuring device intended for various medical purposes, such as to determine the proper length of screws for fastening the ends of a fractured bone.
• Foot Prosthesis
• Forceps (FDA Code: HTD / 878.4800)
A manual surgical instrument for general use is a nonpowered, hand-held, or hand-manipulated device, either reusable or disposable, intended to be used in various general surgical procedures. The device includes the applicator, clip applier, biopsy brush, manual dermabrasion brush, scrub brush, cannula, ligature carrier, chisel, clamp, contractor, curette, cutter, dissector, elevator, skin graft expander, file, forceps, gouge, instrument guide, needle guide, hammer, hemostat, amputation hook, ligature passing and knot-tying instrument, knife, blood lancet, mallet, disposable or reusable aspiration and injection needle, disposable or reusable suturing needle, osteotome, pliers, rasp, retainer, retractor, saw, scalpel blade, scalpel handle, one-piece scalpel, snare, spatula, stapler, disposable or reusable stripper, stylet, suturing apparatus for the stomach and intestine, measuring tape, and calipers. A surgical instrument that has specialized uses in a specific medical specialty is classified in separate regulations in parts 868 through 892.
• General use Surgical Curettes (FDA Code: FZS / 878.4800)
• Gigli Saw Guide
• Guide
• Hinged Knee Prosthesis (FDA Code: HRZ / 888.3480)
A knee joint femorotibial metallic constrained cemented prosthesis is a device intended to be implanted to replace part of a knee joint. The device prevents dislocation in more than one anatomic plane and has components that are linked together. The only knee joint movement allowed by the device is in the sagittal plane. This generic type of device includes prostheses that have an intramedullary stem at both the proximal and distal locations. The upper and lower components may be joined either by a solid bolt or pin, an internally threaded bolt with locking screw, or a bolt retained by circlip. The components of the device are made of alloys, such as cobalt-chromium-molybdenum. The stems of the device may be perforated, but are intended for use with bone cement (888.3027).
• Human Bone Rasps (FDA Code: HTR / 878.4800)
• Humeral (hemi-shoulder) Metallic Uncemented Prosthesis (FDA Code: HSD / 888.3690)
A shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis is a device made of alloys, such as cobalt-chromium-molybdenum. It has an intramedullary stem and is intended to be implanted to replace the articular surface of the proximal end of the humerus and to be fixed without bone cement (888.3027). This device is not intended for biological fixation.
• Impactor (FDA Code: HWA / 888.4540)
An orthopedic manual surgical instrument is a nonpowered hand-held device intended for medical purposes to manipulate tissue, or for use with other devices in orthopedic surgery. This generic type of device includes the cerclage applier, awl, bender, drill brace, broach, burr, corkscrew, countersink, pin crimper, wire cutter, prosthesis driver, extractor, file, fork, needle holder, impactor, bending or contouring instrument, compression instrument, passer, socket positioner, probe, femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench.
• Intramedullary Bone Rasps
• Intramedullary Fixation Rod and Accessories (FDA Code: HSB / 888.3020)
An intramedullary fixation rod is a device intended to be implanted that consists of a rod made of alloys such as cobalt-chromium-molybdenum and stainless steel. It is inserted into the medullary (bone marrow) canal of long bones for the fixation of fractures.
• Joint Prosthesis
• Knee Joint Femorotibial Metal/Polymer Non-constrained Cemented Prosthesis (FDA Code: HSX / 888.3520)
A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended to be implanted to replace part of a knee joint. The device limits minimally (less than normal anatomic constraints) translation in one or more planes. It has no linkage across-the-joint. This generic type of device includes prostheses that have a femoral condylar resurfacing component or components made of alloys, such as cobalt-chromium-molybdenum, and a tibial component or components made of ultra-high molecular weight polyethylene and are intended for use with bone cement (888.3027).
• Large Open Gear Bone Drill
• Manual Trephines & Accessories (FDA Code: HBG / 882.4300)
Manual cranial drills, burrs, trephines, and their accessories are bone cutting and drilling instruments that are used without a power source on a patient's skull.
• Medical Rasps (FDA Code: HTR / 878.4800)
• Metal/Polymer Semi-Constrained Ankle Prosthesis (FDA Code: HSN / 888.3110)
An ankle joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an ankle joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces and has no linkage across-the-joint. This generic type of device includes prostheses that have a talar resurfacing component made of alloys, such as cobalt-chromium-molybdenum, and a tibial resurfacing component made of ultra-high molecular weight polyethylene and is limited to those prostheses intended for use with bone cement (888.3027).
• Metal/Polymer Semi-Constrained Hip Prosthesis (FDA Code: LPH / 888.3358)
A hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis is a device intended to be implanted to replace a hip joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across the joint. This generic type of device has a femoral component made of a cobalt-chromium-molybdenum (Co-Cr-Mo) alloy or a titanium-aluminum-vanadium (Ti-6Al-4V) alloy and an acetabular component composed of an ultra-high molecular weight polyethylene articulating bearing surface fixed in a metal shell made of Co-Cr-Mo or Ti-6Al-4V. The femoral stem and acetabular shell have a porous coating made of, in the case of Co-Cr-Mo substrates, beads of the same alloy, and in the case of Ti-6Al-4V substrates, fibers of commercially pure titanium or Ti-6Al-4V alloy. The porous coating has a volume porosity between 30 and 70 percent, an average pore size between 100 and 1,000 microns, interconnecting porosity, and a porous coating thickness between 500 and 1,500 microns. The generic type of device has a design to achieve biological fixation to bone without the use of bone cement.
• Nail Extractors (FDA Code: HWB / 888.4540)
• Non-Alterable Preformed Skull Bone Plate (FDA Code: GXN / 882.5330)
A preformed nonalterable cranioplasty plate is a device that is implanted in a patient to repair a skull defect and is constructed of a material, e.g., stainless steel or vitallium, that cannot be altered or reshaped at the time of surgery without changing the chemical behavior of the material.
• Non-Cemented Metal Acetabular Component Hip Prosthesis
• Nut Bolt Washer (FDA Code: HTN / 888.3030)
Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.
• Ophthalmology, Surgical Instrument Trays
• Orbital Procedures, Bone Drills
• Orthopaedic Instrument, Universal Bone Drill
• Orthopedic Burr (FDA Code: HTT / 888.4540)
• Orthopedic Cement
• Orthopedic Osteotome (FDA Code: HWM / 878.4800)
• Orthopedic Prosthesis Implantation Instrument
• Orthopedic Wire Passer (FDA Code: HXI / 888.4540)
• Patellar Knee Prosthesis
• Pin Surgical Driver (FDA Code: GFC / 878.4820)
Surgical instrument motors and accessories are AC-powered, battery-powered, or air-powered devices intended for use during surgical procedures to provide power to operate various accessories or attachments to cut hard tissue or bone and soft tissue. Accessories or attachments may include a bur, chisel (osteotome), dermabrasion brush, dermatome, drill bit, hammerhead, pin driver, and saw blade.
• Pneumatic Powered Orthopedic Surgical Instrument & Accessory (FDA Code: HSZ / 878.4820)
• Pressure Monitoring Kit
• Prosthesis Driver (FDA Code: HWR / 888.4540)
• Proximal Femoral Fixation Implant Device (FDA Code: JDO / 888.3030)
• Reamer (FDA Code: HTO / 888.4540)
• Retractors
• Saws (FDA Code: HSO / 878.4800)
• Screwdriver (FDA Code: HXX / 888.4540)
• Semi-Constrained Elbow Prosthesis (FDA Code: JDB / 888.3160)
An elbow joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an elbow joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that consist of a humeral resurfacing component made of alloys, such as cobalt-chromium-molybdenum, and a radial resurfacing component made of ultra-high molecular weight polyethylene. This generic type of device is limited to those prostheses intended for use with bone cement (888.3027).
• Semi-Constrained Femorotibial Knee Prosthesis (FDA Code: HRY / 888.3530)
A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace part of a knee joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that consist of a femoral component made of alloys, such as cobalt-chromium-molybdenum, and a tibial component made of ultra-high molecular weight polyethylene and is limited to those prostheses intended for use with bone cement (888.3027).
• Semi-Constrained Hip Prosthesis (FDA Code: JDL / 888.3320)
A hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis is a two-part device intended to be implanted to replace a hip joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that consist of a femoral and an acetabular component, both made of alloys, such as cobalt-chromium-molybdenum. This generic type of device is limited to those prostheses intended for use with bone cement (888.3027).
• Semi-Constrained Patellofemorotibial Knee Prosthesis (FDA Code: JWH / 888.3560)
A knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a knee joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and a tibial component or components and a retropatellar resurfacing component made of ultra-high molecular weight polyethylene. This generic type of device is limited to those prostheses intended for use with bone cement (888.3027).
• Shoulder joint Prosthesis
• Shoulder Prosthesis
• Skull Bone Plate
• Small Depth Gauge (FDA Code: HTJ / 888.4300)

 Edit or Enhance this Company (732 potential buyers viewed listing)
Browse Category   |   Alphabetical Products   |   ALL 25,000 Suppliers
HomeBuyAdd FREE ListingAdvertise Medical CompanyMedical Portal