Skype

Intelligent Hearing Systems

Click Here To EMAIL INQUIRY
Web: http://www.ihsys.com
E-Mail:
Address: 6860 SW 81st St, Miami, Florida 33143, USA
Phone: +1-(305)-6686102/800 4479783 | Fax: +1-(305)-6686103 | Map/Directions >>
 
 

Profile: Intelligent Hearing Systems concentrates on the development of methods & devices for the diagnosis and treatment of hearing & neurological disorders. We offer products like intelligent VRA systems, video VRA system, smart audiometer and LIPP phonetics program. Our smartEP is available with ABR & OAE diagnostics and screening. Our smartEP ASSR is used to determine audiogram. Our product DPOAE & TrOAE is used for acoustic emission testing. Our intelligent VRA systems is the first sophisticated, automated, audiometric tool that gives accurate, quick and cost-effective hearing screening and testing for infants, children and developmentally delayed individuals. In screening mode, it is extremely sensitive in identifying hearing losses quickly and accurately. In testing mode, sensory thresholds can efficiently be established for four frequencies. The addition of video reinforcers provides with unlimited reinforce options for challenging infants. It also supports upgrading to intelligent vrisd to include infant speech discrimination. Our CHATS, the miami cochlear implant, auditory and tactile skills curriculum is a comprehensive manual for training deaf and hard of hearing children in the use of sensory aids for speech perception and production. It has been written by a team of speech-language pathologists, audiologists, teachers of the hearing impaired, and early childhood development specialists to be a hands-on guide for communication training.

The company was founded in 1983, has revenues of USD 1-5 Million, has ~20 employees and is ISO, CE certified.

FDA Registration Number: 1052723

28 Products/Services (Click for related suppliers)  
• AC-Powered Speech Training Aid (FDA Code: LEZ)
• Audiometers (FDA Code: EWO / 874.1050)
An audiometer or automated audiometer is an electroacoustic device that produces controlled levels of test tones and signals intended for use in conducting diagnostic hearing evaluations and assisting in the diagnosis of possible otologic disorders.
• Audiometers & Accessories
• Audiometric Evoked Potential Unit
• Audiometric Test Kits
• Audiometry Compute
• Auditory Evoked Response Unit
• Auditory Impedance Tester (FDA Code: ETY / 874.1090)
An auditory impedance tester is a device that is intended to change the air pressure in the external auditory canal and measure and graph the mobility characteristics of the tympanic membrane to evaluate the functional condition of the middle ear. The device is used to determine abnormalities in the mobility of the tympanic membrane due to stiffness, flaccidity, or the presence of fluid in the middle ear cavity. The device is also used to measure the acoustic reflex threshold from contractions of the stapedial muscle, to monitor healing of tympanic membrane grafts or stapedectomies, or to monitor followup treatment for inflammation of the middle ear.
• Brainstem Response Devices
• Cutaneous Electrode (FDA Code: GXY / 882.1320)
A cutaneous electrode is an electrode that is applied directly to a patient's skin either to record physiological signals (e.g., the electroencephalogram) or to apply electrical stimulation.
• Diagnostic Test Kits
• Earphones
• Earphones, Audiometric Testing
• ENT Computer Software
• ENT Educational Materials
• ENT Nerve Stimulator (FDA Code: ETN / 874.1820)
A surgical nerve stimulator/locator is a device that is intended to provide electrical stimulation to the body to locate and identify nerves and to test their excitability.
• Evoked Response Auditory Stimulator (FDA Code: GWJ / 882.1900)
An evoked response auditory stimulator is a device that produces a sound stimulus for use in evoked response measurements or electroencephalogram activation.
• Evoked Response Electrical Stimulator (FDA Code: GWF / 882.1870)
An evoked response electrical stimulator is a device used to apply an electrical stimulus to a patient by means of skin electrodes for the purpose of measuring the evoked response.
• Evoked Response Photic Stimulator (FDA Code: GWE / 882.1890)
An evoked response photic stimulator is a device used to generate and display a shifting pattern or to apply a brief light stimulus to a patient's eye for use in evoked response measurements or for electroencephalogram (EEG) activation.
• Evoked Response Simulators
• Evoked Response Testing Systems
• Infant Screening & Testing Units
• Medical Books
• Otoacoustic Emission Test Equipment
• Pediatric ENT Testing Kits
• Physiological Signal Amplifier (FDA Code: GWL / 882.1835)
A physiological signal amplifier is a general purpose device used to electrically amplify signals derived from various physiological sources (e.g., the electroencephalogram).
• Speech & Testing Equipment
• Vestibular Testing Kits

 Edit or Enhance this Company (1019 potential buyers viewed listing,  102 forwarded to manufacturer's website)
Browse Category   |   Alphabetical Products   |   ALL 25,000 Suppliers
HomeBuyAdd FREE ListingAdvertise Medical CompanyMedical Portal