Skype

Jostra Bentley, Inc.


Address: Rd. 402 N. Km 1.4, Industrial Park, Anasco 00610-1577, USA
Phone: +1-(302)-454-9959 | Map/Directions >>
 
 

Profile: Jostra Bentley, Inc. offers various surgical and disposable medical products. We provide arterial filters, blood infusion line, cardioplegia cooling/administration set, cardiotomy venous reservoirs, custom cardiovascular perfusion kits, disposable sucker, oxygen saturation meter, pleural drainage/autotransfusion system, surgical grade tubing and various types of cardiopulmonary bypass device holders.

16 Products/Services (Click for related suppliers)  
• Arterial Blood Sampling Kit (FDA Code: CBT / 868.1100)
An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples from a patient for blood gas determinations. The kit may include a syringe, needle, cork, and heparin.
• Arterial Line Cardiopulmonary Bypass Blood Filter (FDA Code: DTM / 870.4260)
A cardiopulmonary bypass arterial line blood filter is a device used as part of a gas exchange (oxygenator) system to filter nonbiologic particles and emboli (blood clots or pieces of foreign material flowing in the bloodstream which will obstruct circulation by blocking a vessel) out of the blood. It is used in the arterial return line.
• Autotransfusion Apparatus (FDA Code: CAC / 868.5830)
An autotransfusion apparatus is a device used to collect and reinfuse the blood lost by a patient due to surgery or trauma.
• Breathing Circuit Bacterial Filter (FDA Code: CAH / 868.5260)
A breathing circuit bacterial filter is a device that is intended to remove microbiological and particulate matter from the gases in the breathing circuit.
• Cardiopulmonary Bypass Accessories (FDA Code: KRI / 870.4200)
Cardiopulmonary bypass accessory equipment is a device that has no contact with blood and that is used in the cardiopulmonary bypass circuit to support, adjoin, or connect components, or to aid in the setup of the extracorporeal line, e.g., an oxygenator mounting bracket or system-priming equipment.
• Cardiopulmonary Bypass Blood Reservoir (FDA Code: DTN / 870.4400)
A cardiopulmonary bypass blood reservoir is a device used in conjunction with short-term extracorporeal circulation devices to hold a reserve supply of blood in the bypass circulation.
• Cardiopulmonary Bypass Cardiotomy Return Sucker (FDA Code: DTS / 870.4420)
A cardiopulmonary bypass cardiotomy return sucker is a device that consists of tubing, a connector, and a probe or tip that is used to remove blood from the chest or heart during cardiopulmonary bypass surgery.
• Cardiopulmonary Bypass Heat Exchanger (FDA Code: DTR / 870.4240)
A cardiopulmonary bypass heat exchanger is a device, consisting of a heat exchange system used in extracorporeal circulation to warm or cool the blood or perfusion fluid flowing through the device.
• Cardiopulmonary Bypass Oxygenator (FDA Code: DTZ / 870.4350)
A cardiopulmonary bypass oxygenator is a device used to exchange gases between blood and a gaseous environment to satisfy the gas exchange needs of a patient during open-heart surgery.
• Cardiopulmonary Bypass Pump Tube (FDA Code: DWE / 870.4390)
A cardiopulmonary bypass pump tubing is polymeric tubing which is used in the blood pump head and which is cyclically compressed by the pump to cause the blood to flow through the cardiopulmonary bypass circuit.
• Cardiopulmonary Bypass Vascular Catheter (FDA Code: DWF / 870.4210)
A cardiopulmonary bypass vascular catheter, cannula, or tubing is a device used in cardiopulmonary surgery to cannulate the vessels, perfuse the coronary arteries, and to interconnect the catheters and cannulas with an oxygenator. The device includes accessory bypass equipment.
• Diagnostic Automated Blood Cell Separator (FDA Code: GKT / 864.9245)
• Dry and Liquid Heparin Arterial Blood Sampling Kits
• Infusion Line Filter (FDA Code: FPB / 880.5440)
An intravascular administration set is a device used to administer fluids from a container to a patient's vascular system through a needle or catheter inserted into a vein. The device may include the needle or catheter, tubing, a flow regulator, a drip chamber, an infusion line filter, an I.V. set stopcock, fluid delivery tubing, connectors between parts of the set, a side tube with a cap to serve as an injection site, and a hollow spike to penetrate and connect the tubing to an I.V. bag or other infusion fluid container.
• Intravenous Administration Kit (FDA Code: FPA / 880.5440)
• Oximeters (FDA Code: DQA / 870.2700)
An oximeter is a device used to transmit radiation at a known wavelength(s) through blood and to measure the blood oxygen saturation based on the amount of reflected or scattered radiation. It may be used alone or in conjunction with a fiberoptic oximeter catheter.