Profile: Kinamed Inc is a designer and manufacturer of implantables and instruments for orthopedics and neurosurgery. We offer CarboJet® carbon dioxide lavage system for cleaning and preparing bone surfaces for orthopedic procedures, SuperCable™ Iso-Elastic™ Cerclage system for solve many of the inherent problems of traditional monofilament wire and cabling systems, KineMatch™ Patello-femoral replacement for joint replacement of patients with isolated, end-stage patello-femoral disease, & NaviPro™ hip, knee, and shoulder. We develop NeuroPro® fixation system, which is used for neurosurgical applications. We focus on craniotomy, cranioplasty and skull base applications.
The company was founded in 1987, has revenues of USD 5-10 Million, has ~20 employees and is ISO 9001, CE certified. NASDAQ:SMA (SEC Filings)
FDA Registration Number: 2027148
33 Products/Services (Click for related suppliers)
|
• AC-Powered Motor Orthopedic Surgical Instrument (FDA Code: HWE / 878.4820) Surgical instrument motors and accessories are AC-powered, battery-powered, or air-powered devices intended for use during surgical procedures to provide power to operate various accessories or attachments to cut hard tissue or bone and soft tissue. Accessories or attachments may include a bur, chisel (osteotome), dermabrasion brush, dermatome, drill bit, hammerhead, pin driver, and saw blade. |
• Acetabular Components |
• Bone Fixation Plate (FDA Code: HRS / 888.3030) Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system. |
• Bone Fixation Screw (FDA Code: HWC / 888.3040) A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system. |
• Calicum-Phosphate Non-Porous Metal/Polymer Uncemented Semi-Constrained Hip Prosthesis (FDA Code: MEH / 888.3353) A hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis is a device intended to be implanted to replace a hip joint. This device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. The two-part femoral component consists of a femoral stem made of alloys to be fixed in the intramedullary canal of the femur by impaction with or without use of bone cement. The proximal end of the femoral stem is tapered with a surface that ensures positive locking with the spherical ceramic (aluminium oxide, A1203) head of the femoral component. The acetabular component is made of ultra-high molecular weight polyethylene or ultra-high molecular weight polyethylene reinforced with nonporous metal alloys, and used with or without bone cement. |
• Cemented Metal/Polymer Semi-Constrained Hip Prosthesis (FDA Code: JDI / 888.3350) A hip joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a hip joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and an acetabular resurfacing component made of ultra-high molecular weight polyethylene and is limited to those prostheses intended for use with bone cement (888.3027). |
• CO2 Lavage System |
• Computer-assisted Surgical Systems |
• Femoral Components |
• Femoral Head Prosthesis |
• Fixation Cerclage (FDA Code: JDQ / 888.3010) A bone fixation cerclage is a device intended to be implanted that is made of alloys, such as cobalt-chromium-molybdenum, and that consists of a metallic ribbon or flat sheet or a wire. The device is wrapped around the shaft of a long bone, anchored to the bone with wire or screws, and used in the fixation of fractures. |
• Hip Replacement Instrumentation Kit |
• Hip Replacement, Femoral Heads |
• Knee Replacement, Primary Component |
• Metal Femoral Hemi- Hip Prosthesis (FDA Code: KWL / 888.3360) A hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis is a device intended to be implanted to replace a portion of the hip joint. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum. This generic type of device includes designs which are intended to be fixed to the bone with bone cement (888.3027) as well as designs which have large window-like holes in the stem of the device and which are intended for use without bone cement. However, in these latter designs, fixation of the device is not achieved by means of bone ingrowth. |
• Metal/Polymer Semi-Constrained Hip Prosthesis (FDA Code: LPH / 888.3358) A hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis is a device intended to be implanted to replace a hip joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across the joint. This generic type of device has a femoral component made of a cobalt-chromium-molybdenum (Co-Cr-Mo) alloy or a titanium-aluminum-vanadium (Ti-6Al-4V) alloy and an acetabular component composed of an ultra-high molecular weight polyethylene articulating bearing surface fixed in a metal shell made of Co-Cr-Mo or Ti-6Al-4V. The femoral stem and acetabular shell have a porous coating made of, in the case of Co-Cr-Mo substrates, beads of the same alloy, and in the case of Ti-6Al-4V substrates, fibers of commercially pure titanium or Ti-6Al-4V alloy. The porous coating has a volume porosity between 30 and 70 percent, an average pore size between 100 and 1,000 microns, interconnecting porosity, and a porous coating thickness between 500 and 1,500 microns. The generic type of device has a design to achieve biological fixation to bone without the use of bone cement. |
• Multiple Component Fixation Appliance (FDA Code: KTT / 888.3030) |
• Neuro Fixation System |
• Neurological Stereotaxic Instrument (FDA Code: HAW / 882.4560) A stereotaxic instrument is a device consisting of a rigid frame with a calibrated guide mechanism for precisely positioning probes or other devices within a patient's brain, spinal cord, or other part of the nervous system. |
• Patello-Femoral Replacement System |
• Primary Femoral Components |
• Revision Acetabular Components |
• Revision Femoral Components |
• Semi-Constrained Patellofemoral Knee Prosthesis (FDA Code: KRR / 888.3540) A knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis is a two-part device intended to be implanted to replace part of a knee joint in the treatment of primary patellofemoral arthritis or chondromalacia. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes a component made of alloys, such as cobalt-chromium-molybdenum or austenitic steel, for resurfacing the intercondylar groove (femoral sulcus) on the anterior aspect of the distal femur, and a patellar component made of ultra-high molecular weight polyethylene. This generic type of device is limited to those devices intended for use with bone cement (888.3027). The patellar component is designed to be implanted only with its femoral component. |
• Semi-Constrained Patellofemorotibial Knee Prosthesis (FDA Code: JWH / 888.3560) A knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a knee joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and a tibial component or components and a retropatellar resurfacing component made of ultra-high molecular weight polyethylene. This generic type of device is limited to those prostheses intended for use with bone cement (888.3027). |
• Skull Bone Plate |
• Surgical Navigation |
• Surgical Navigation Interface/Display |
• Surgical Navigation Systems |
• Total Knee Prosthesis |
• Uncemented Metal/Polymer Semi-Constrained Hip Prosthesis (FDA Code: LWJ / 888.3360) |
• Uncemented, Cemented Or Non-Porous Metal/Ceramic/Polymer Semi-Constrained Hip Prosthesis (FDA Code: LZO / 888.3353) |
• Water Jet Lavage Unit (FDA Code: FQH / 880.5475) A jet lavage is a device used to clean a wound by a pulsatile jet of sterile fluid. The device consists of the pulsing head, tubing to connect to a container of sterile fluid, and a means of propelling the fluid through the tubing, such as an electric roller pump. |