Profile: Levitronix LLC supplies medical blood pumps. Our Centrimag® blood pumping has a single-use blood pump, primary console & motor and a back-up console & motor, providing a hemodynamic support for patients suffering from cardiogenic shock. Our systems are designed to provide mechanical circulatory support for thirty days, to the patients suffering from severe to acute potentially reversible cardiac failure. Our pumping system is used to pump blood through the extracorporeal bypass circuit for extracorporeal circulatory support for periods appropriate to cardiopulmonary bypass of up to six hours. It is indicated for use in extracorporeal support systems not requiring complete cardiopulmonary bypass, which includes valvuloplasty, circulatory support during mitral valve reoperation, surgery of the vena cava or aorta and liver transplants. We also produce Centrimag® ventricular assist system that is used in the treatment of cardiogenic shock under an investigational device exemption, which is attached to the patient using standard surgical techniques.
8 Products/Services (Click for related suppliers)
|
• Blood Pump Systems |
• Blood Pumping Systems |
• Cardiopulmonary Bypass Pump Speed Controller (FDA Code: DWA / 870.4380) A cardiopulmonary bypass pump speed control is a device used that incorporates an electrical system or a mechanical system, or both, and is used to control the speed of blood pumps used in cardiopulmonary bypass surgery. |
• Extracorporeal Blood Pumping Systems |
• Extracorporeal Blood System and Accessories (FDA Code: LLB / 876.5820) A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer. |
• Medical Blood Pumps |
• Non-Roller Type Cardiopulmonary Bypass Blood Pump (FDA Code: KFM / 870.4360) A nonroller-type cardiopulmonary bypass blood pump is a device that uses a method other than revolving rollers to pump the blood through the cardiopulmonary bypass circuit during bypass surgery. |
• Ventricular Assist Systems |