Skype

MIE Medical Research Ltd.

Click Here To EMAIL INQUIRY
Contact: Vladya Ellis - Director of Marketing
Web: http://www.mie-uk.com
E-Mail:
Address: 6 Wortley Moor Road, Leeds LS12 4JF, United Kingdom
Phone: +44-(113)-279-3710 | Fax: +44-(113)-231-0820 | Map/Directions >>
 
 

Profile: MIE Medical Research Ltd. specializes in human performance monitoring instruments for use in bioengineering, ergonomics, sports sciences, medicine, physiotherapy and work diagnostics. We have a diverse range of hardware & software products and we are able to manufacture special bespoke instruments. Clinical goniometer is designed specifically for use by rheumatologists, physiotherapists and general practitioners. The rotating dial of the compass is turned so that it lines up with the needle. Bearings are then taken by pointing the compass at distant objects and reading the angle to which the needle is pointing. The clinical goniometer uses gravity as its reference rather than magnetic north and consequently is used vertically, whereas the compass is used horizontally. The Pinch/Grip analyzer measures both hand grip finger key grip pinch performance. The handle is made from a special lightweight but stiff aerospace alloy and is adjustable to accommodate all hand sizes & fixed flexion deformities. Our patented design overcomes any leverage effects when gripping the handle, so that the measured force is the same, irrespective of hand position. Finger strength can therefore be measured when the handles are adjusted to their minimum separation. The therapist is able to support the entire weight of the handle to administer tests on particularly frail subjects. The myometer is a multi-force analyzer for measuring the magnitude of isometric contractions of many muscle groups. The transducer measures force which is automatically converted by the software to the useful measure of torque (Nm) about a joint. The calculation of torque is made from a simple measurement of the lever arm length during the test set-up procedure and ensures that the data are presented in standard meaningful units of measurement.

The company has revenues of < USD 1 Million, has ~20 employees and is ISO 9002, CE certified.

FDA Registration Number: 8021863
US Agent: Rich Richardson / Richardson Products Inc
Phone: +1-(815)-464-3575  E-Mail:

5 Products/Services (Click for related suppliers)  
• EMG Physiological Telemetry Unit
• Mechanical Goniometer
• Motion Analyzer
• Non-Powered Dynamometer (FDA Code: HRW / 888.1250)
A nonpowered dynamometer is a mechanical device intended for medical purposes to measure the pinch and grip muscle strength of a patient's hand.
• Non-Powered Goniometer (FDA Code: KQW / 888.1520)
A nonpowered goniometer is a mechanical device intended for medical purposes to measure the range of motion of joints.

 Edit or Enhance this Company (243 potential buyers viewed listing,  16 forwarded to manufacturer's website)
Browse Category   |   Alphabetical Products   |   ALL 25,000 Suppliers
HomeBuyAdd FREE ListingAdvertise Medical CompanyMedical Portal