Profile: Medcomp manufactures and distributes vascular access catheters. Our products are used in hemodialysis, peritoneal dialysis, and other vascular access procedures. The Soft-Line™ material on our Duo-Flow™ double lumen catheter addresses several of the major concerns facing dialysis health care clinicians. The Soft-Line™ material allows the stability needed for a standard Seldinger insertion, and offers softer material thereby reducing the probability of stenosis & vessel erosion caused by rigid catheters. The fixed circular tube within a tube allows for a 360° arterial uptake and provides consistent flows up to 350 ml/min. The short term access Hemo-Cath® catheter is a double lumen catheter designed with a tapered tip that allows insertion via the Seldinger technique. The internal stiffening stylet provides adequate rigidity during insertion. When the stylet is removed along with the guidewire, an extremely soft, kink-resistent cannula is left in the vessel. The flexible cannula conforms to vessel anatomy, providing safety and comfort once in the vessel. The green anchoring clip curves the extensions for subclavian or internal jugular approaches.
The company is ISO, CE certified.
FDA Registration Number: 2518902
21 Products/Services (Click for related suppliers)
|
• Catheter Introducers (FDA Code: DYB / 870.1340) A catheter introducer is a sheath used to facilitate placing a catheter through the skin into a vein or artery. |
• Catheters |
• Dialysis Catheters |
• Femoral Catheter (FDA Code: LFK / 876.5540) A blood access device and accessories is a device intended to provide access to a patient's blood for hemodialysis or other chronic uses. When used in hemodialysis, it is part of an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and provides access to a patient's blood for hemodialysis. The device includes implanted blood access devices, nonimplanted blood access devices, and accessories for both the implanted and nonimplanted blood access devices. |
• General & Plastic Surgery Ventricular Catheter (FDA Code: GBS / 878.4200) An introduction/drainage catheter is a device that is a flexible single or multilumen tube intended to be used to introduce nondrug fluids into body cavities other than blood vessels, drain fluids from body cavities, or evaluate certain physiologic conditions. Examples include irrigation and drainage catheters, pediatric catheters, peritoneal catheters (including dialysis), and other general surgical catheters. An introduction/drainage catheter accessory is intended to aid in the manipulation of or insertion of the device into the body. Examples of accessories include adaptors, connectors, and catheter needles. |
• Guidewire Catheter (FDA Code: DQX / 870.1330) A catheter guide wire is a coiled wire that is designed to fit inside a percutaneous catheter for the purpose of directing the catheter through a blood vessel. |
• Guidewires |
• Hemodialysis Catheter Repair Kit (FDA Code: NFK / 876.5540) |
• Hemodialysis systems |
• Implanted Hemodialysis Catheter (FDA Code: MSD / 876.5540) |
• Implanted Subcutaneous Intravascular Port & Catheter (FDA Code: LJT / 880.5965) A subcutaneous, implanted, intravascular infusion port and catheter is a device that consists of a subcutaneous, implanted reservoir that connects to a long-term intravascular catheter. The device allows for repeated access to the vascular system for the infusion of fluids and medications and the sampling of blood. The device consists of a portal body with a resealable septum and outlet made of metal, plastic, or combination of these materials and a long-term intravascular catheter is either preattached to the port or attached to the port at the time of device placement. The device is available in various profiles and sizes and can be of a single or multiple lumen design. |
• Intravenous Administration Kit (FDA Code: FPA / 880.5440) An intravascular administration set is a device used to administer fluids from a container to a patient's vascular system through a needle or catheter inserted into a vein. The device may include the needle or catheter, tubing, a flow regulator, a drip chamber, an infusion line filter, an I.V. set stopcock, fluid delivery tubing, connectors between parts of the set, a side tube with a cap to serve as an injection site, and a hollow spike to penetrate and connect the tubing to an I.V. bag or other infusion fluid container. |
• Long-Term Indwelling Peritoneal Catheter (FDA Code: FJS / 876.5630) (1) A peritoneal dialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions, and that consists of a peritoneal access device, an administration set for peritoneal dialysis, a source of dialysate, and, in some cases, a water purification mechanism. After the dialysate is instilled into the patient's peritoneal cavity, it is allowed to dwell there so that undesirable substances from the patient's blood pass through the lining membrane of the peritoneal cavity into this dialysate. These substances are then removed when the dialysate is drained from the patient. The peritoneal dialysis system may regulate and monitor the dialysate temperature, volume, and delivery rate together with the time course of each cycle of filling, dwell time, and draining of the peritoneal cavity or manual controls may be used. This generic device includes the semiautomatic and the automatic peritoneal delivery system. |
• Non-Implanted Hemodialysis Catheters (FDA Code: MPB / 876.5540) |
• Non-Implanted Triple Lumen Hemodialysis Catheter (FDA Code: NIE / 876.5540) |
• Packaging |
• Percutaneous Catheterization Vessel Dilator (FDA Code: DRE / 870.1310) A vessel dilator for percutaneous catheterization is a device which is placed over the guide wire to enlarge the opening in the vessel, and which is then removed before sliding the catheter over the guide wire. |
• Short-Term Less Than 30 Days Therapeutic Intravascular Catheter (FDA Code: FOZ / 880.5200) An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patient's vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or administer fluids intravenously. The device may be constructed of metal, rubber, plastic, or a combination of these materials. |
• Subclavian Catheter (FDA Code: LFJ / 876.5540) |
• Therapeutic Intravascular Catheter (FDA Code: LJS / 880.5970) A percutaneous, implanted, long-term intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings, such as luer hubs, and accessories that facilitate the placement of the device. The device allows for repeated access to the vascular system for long-term use of 30 days or more, and it is intended for administration of fluids, medications, and nutrients; the sampling of blood; and monitoring blood pressure and temperature. The device may be constructed of metal, rubber, plastic, composite materials, or any combination of these materials and may be of single or multiple lumen design. |
• Vascular Catheter |