Profile: Orvim Srl manufactures sub-assemblies for instruments of coagulation and blood gas analyzers.
FDA Registration Number: 3003192909
US Agent: Hossein Maleknia / Magellan Diagnostics
Phone: +1-(978)-250-7011 Fax: +1-(978)-600-1480 E-Mail:
15 Products/Services (Click for related suppliers)
|
• Blood Gas Analyzers |
• Blood Gas and Ph Electrode Measurement (FDA Code: CHL / 862.1120) A blood gases (PCO2, PO2) and blood pH test system is a device intended to measure certain gases in blood, serum, plasma or pH of blood, serum, and plasma. Measurements of blood gases (PCO2, PO2) and blood pH are used in the diagnosis and treatment of life-threatening acid-base disturbances. |
• Blood Gas Capillary Tubes |
• Blood Gas Controls (FDA Code: JJS / 862.1660) A quality control material (assayed and unassayed) for clinical chemistry is a device intended for medical purposes for use in a test system to estimate test precision and to detect systematic analytical deviations that may arise from reagent or analytical instrument variation. A quality control material (assayed and unassayed) may be used for proficiency testing in interlaboratory surveys. This generic type of device includes controls (assayed and unassayed) for blood gases, electrolytes, enzymes, multianalytes (all kinds), single (specified) analytes, or urinalysis controls. |
• Blood Gas Monitors |
• Blood Gas Sampling Kit |
• Blood Gas/pH analyzer |
• Calcium Ion Specific Electrode (FDA Code: JFP / 862.1145) A calcium test system is a device intended to measure the total calcium level in serum. Calcium measurements are used in the diagnosis and treatment of parathyroid disease, a variety of bone diseases, chronic renal disease and tetany (intermittent muscular contractions or spasms). |
• Chloride Ion Specific Electrode (FDA Code: CGZ / 862.1170) A chloride test system is a device intended to measure the level of chloride in plasma, serum, sweat, and urine. Chloride measurements are used in the diagnosis and treatment of electrolyte and metabolic disorders such as cystic fibrosis and diabetic acidosis. |
• Fibrinogen Determination Standard and Control (FDA Code: GFK / 864.7340) A fibrinogen determination system is a device that consists of the instruments, reagents, standards, and controls used to determine the fibrinogen levels in disseminated intravascular coagulation (nonlocalized clotting within the blood vessels) and primary fibrinolysis (the dissolution of fibrin in a blood clot). |
• Glucose Oxidase, Glucose (FDA Code: CGA / 862.1345) A glucose test system is a device intended to measure glucose quantitatively in blood and other body fluids. Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus, neonatal hypoglycemia, and idiopathic hypoglycemia, and of pancreatic islet cell carcinoma. |
• Oxygen Blood Gas Monitor |
• Potassium Ion Specific Electrode (FDA Code: CEM / 862.1600) A potassium test system is a device intended to measure potassium in serum, plasma, and urine. Measurements obtained by this device are used to monitor electrolyte balance in the diagnosis and treatment of diseases conditions characterized by low or high blood potassium levels. |
• Sodium Ion Specific Electrode (FDA Code: JGS / 862.1665) A sodium test system is a device intended to measure sodium in serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment of aldosteronism (excessive secretion of the hormone aldosterone), diabetes insipidus (chronic excretion of large amounts of dilute urine, accompanied by extreme thirst), adrenal hypertension, Addison's disease (caused by destruction of the adrenal glands), dehydration, inappropriate antidiuretic hormone secretion, or other diseases involving electrolyte imbalance. |
• Whole Blood Oximeter (FDA Code: GLY / 864.7500) A whole blood hemoglobin assay is a device consisting or reagents, calibrators, controls, or photometric or spectrophotometric instrumentation used to measure the hemoglobin content of whole blood for the detection of anemia. This generic device category does not include automated hemoglobin systems. |