Skype

Precision Systems, Inc.

Click Here To EMAIL INQUIRY
Contact: Robert Atwood - VP Manufacturing
Web: http://www.nbizz.com/precisionsystemsinc
E-Mail:
Address: 16 Tech Circle, Natick, Massachusetts 01760-1029, USA
Phone: +1-(508)-655-7010 | Fax: +1-(508)-653-6999 | Map/Directions >>
 
 

Profile: Precision Systems, Inc. develops automated digital readout osmometers, micro multi-sample osmometers, and the self-calibrating osmometers for 10 µl micro samples,for use in the clinical chemistry laboratory. We manufacture milk cryoscopes, chemistry cryoscopes, and petroleum molecular weight cryoscopes. We develop flexible computer controlled random access chemical analyzer, the Analette™.

The company was founded in 1964, has revenues of USD 1-5 Million, has ~20 employees.

FDA Registration Number: 1250003

30 Products/Services (Click for related suppliers)  
• Amylase Catalytic Method Test (FDA Code: JFJ / 862.1070)
An amylase test system is a device intended to measure the activity of the enzyme amylase in serum and urine. Amylase measurements are used primarily for the diagnosis and treatment of pancreatitis (inflammation of the pancreas).
• Ast/Sgot Nadh Oxidation/Nad Reduction (FDA Code: CIT / 862.1100)
An aspartate amino transferase (AST/SGOT) test system is a device intended to measure the activity of the enzyme aspartate amino transferase (AST) (also known as a serum glutamic oxaloacetic transferase or SGOT) in serum and plasma. Aspartate amino transferase measurements are used in the diagnosis and treatment of certain types of liver and heart disease.
• Bilirubin Diazo Colorimetry Test (FDA Code: CIG / 862.1110)
A bilirubin (total or direct) test system is a device intended to measure the levels of bilirubin (total or direct) in plasma or serum. Measurements of the levels of bilirubin, an organic compound formed during the normal and abnormal distruction of red blood cells, if used in the diagnosis and treatment of liver, hemolytic hematological, and metabolic disorders, including hepatitis and gall bladder block.
• Bromcresol Green Dye-Binding, Albumin (FDA Code: CIX / 862.1035)
An albumin test system is a device intended to measure the albumin concentration in serum and plasma. Albumin measurements are used in the diagnosis and treatment of numerous diseases involving primarily the liver or kidneys.
• Calcium Azo-Dye (FDA Code: CJY / 862.1145)
A calcium test system is a device intended to measure the total calcium level in serum. Calcium measurements are used in the diagnosis and treatment of parathyroid disease, a variety of bone diseases, chronic renal disease and tetany (intermittent muscular contractions or spasms).
• Carbon-Dioxide Enzymatic (FDA Code: KHS / 862.1160)
A bicarbonate/carbon dioxide test system is a device intended to measure bicarbonate/carbon dioxide in plasma, serum, and whole blood. Bicarbonate/carbon dioxide measurements are used in the diagnosis and treatment of numerous potentially serious disorders associated with changes in body acid-base balance.
• Chloride Phosphoric-Tungstic (Spectrophotometric) Acid (FDA Code: CHG / 862.1170)
A chloride test system is a device intended to measure the level of chloride in plasma, serum, sweat, and urine. Chloride measurements are used in the diagnosis and treatment of electrolyte and metabolic disorders such as cystic fibrosis and diabetic acidosis.
• Colorimetric Uric Acid Test (FDA Code: KNK / 862.1775)
A uric acid test system is a device intended to measure uric acid in serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment of numerous renal and metabolic disorders, including renal failure, gout, leukemia, psoriasis, starvation or other wasting conditions, and of patients receiving cytotoxic drugs.
• Cryoscope
• Data Processing Module for Clinical use (FDA Code: JQP / 862.2100)
A calculator/data processing module for clinical use is an electronic device intended to store, retrieve, and process laboratory data.
• Dialysis Unit Test Equipment (Kidney, Engineering)
• Enzymatic Esterase-Oxidase, Cholesterol (FDA Code: CHH / 862.1175)
A cholesterol (total) test system is a device intended to measure cholesterol in plasma and serum. Cholesterol measurements are used in the diagnosis and treatment of disorders involving excess cholesterol in the blood and lipid and lipoprotein metabolism disorders.
• Ferrozine Iron Binding Capacity Test (FDA Code: JMO / 862.1415)
An iron-binding capacity test system is a device intended to measure iron-binding capacity in serum. Iron-binding capacity measurements are used in the diagnosis and treatment of anemia.
• Fluorometric Calcium (FDA Code: JFO / 862.1145)
• Gamma-Glutamyl Transpeptidase Kinetic Method (FDA Code: JQB / 862.1360)
A gamma-glutamyl transpeptidase and isoenzymes test system is a device intended to measure the activity of the enzyme gamma-glutamyl transpeptidase (GGTP) in plasma and serum. Gamma-glutamyl transpeptidase and isoenzymes measurements are used in the diagnosis and treatment of liver diseases such as alcoholic cirrhosis and primary and secondary liver tumors.
• Glucose Oxidase, Glucose (FDA Code: CGA / 862.1345)
A glucose test system is a device intended to measure glucose quantitatively in blood and other body fluids. Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus, neonatal hypoglycemia, and idiopathic hypoglycemia, and of pancreatic islet cell carcinoma.
• HDL Precipitation Method (FDA Code: LBR / 862.1475)
A lipoprotein test system is a device intended to measure lipoprotein in serum and plasma. Lipoprotein measurements are used in the diagnosis and treatment of lipid disorders (such as diabetes mellitus), atherosclerosis, and various liver and renal diseases.
• Inorganic Phosphorus Phosphomolybdate (FDA Code: CEO / 862.1580)
A phosphorus (inorganic) test system is a device intended to measure inorganic phosphorus in serum, plasma, and urine. Measurements of phosphorus (inorganic) are used in the diagnosis and treatment of various disorders, including parathyroid gland and kidney diseases, and vitamin D imbalance.
• Iron Reagent (FDA Code: CFM / 862.1410)
An iron (non-heme) test system is a device intended to measure iron (non-heme) in serum and plasma. Iron (non-heme) measurements are used in the diagnosis and treatment of diseases such as iron deficiency anemia, hemochromatosis (a disease associated with widespread deposit in the tissues of two iron-containing pigments, hemosiderin and hemofuscin, and characterized by pigmentation of the skin), and chronic renal disease.
• Lactate Dehydrogenase NAD Reduction/NADH Oxidation (FDA Code: CFJ / 862.1440)
A lactate dehydrogenase test system is a device intended to measure the activity of the enzyme lactate dehydrogenase in serum. Lactate dehydrogenase measurements are used in the diagnosis and treatment of liver diseases such as acute viral hepatitis, cirrhosis, and metastatic carcinoma of the liver, cardiac diseases such as myocardial infarction, and tumors of the lung or kidneys.
• LDL & VLDL Precipitation Method (FDA Code: LBR / 862.1475)
• Magnesium Photometric Method Test (FDA Code: JGJ / 862.1495)
A magnesium test system is a device intended to measure magnesium levels in serum and plasma. Magnesium measurements are used in the diagnosis and treatment of hypomagnesemia (abnormally low plasma levels of magnesium) and hypermagnesemia (abnormally high plasma levels of magnesium).
• Micro Chemistry Analyzer (FDA Code: JJF / 862.2170)
A micro chemistry analyzer for clinical use is a device intended to duplicate manual analytical procedures by performing automatically various steps such as pipetting, preparing filtrates, heating, and measuring color intensity. The distinguishing characteristic of the device is that it requires only micro volume samples obtainable from pediatric patients. This device is intended for use in conjunction with certain materials to measure a variety of analytes.
• Nadh Oxidation/Nad Reduction (FDA Code: CKA / 862.1030)
An alanine amino transferase (ALT/SGPT) test system is a device intended to measure the activity of the enzyme alanine amino transferase (ALT) (also known as a serum glutamic pyruvic transaminase or SGPT) in serum and plasma. Alanine amino transferase measurements are used in the diagnosis and treatment of certain liver diseases (e.g., viral hepatitis and cirrhosis) and heart diseases.
• Nitrophenylphosphate, Alkaline Phosphatase (FDA Code: CJE / 862.1050)
An alkaline phosphatase or isoenzymes test system is a device intended to measure alkaline phosphatase or its isoenzymes (a group of enzymes with similar biological activity) in serum or plasma. Measurements of alkaline phosphatase or its isoenzymes are used in the diagnosis and treatment of liver, bone, parathyroid, and intestinal diseases.
• Osmometer for Clinical Use (FDA Code: JJM / 862.2730)
An osmometer for clinical use is a device intended to measure the osmotic pressure of body fluids. Osmotic pressure is the pressure required to prevent the passage of a solution with a lesser solute concentration into a solution with greater solute concentration when the two solutions are separated by a semipermeable membrane. The concentration of a solution affects its osmotic pressure, freezing point, and other physiochemical properties. Osmometers determine osmotic pressure by methods such as the measurement of the freezing point. Measurements obtained by this device are used in the diagnosis and treatment of body fluid disorders.
• Sahli Pipette (FDA Code: GGX / 864.6160)
A manual blood cell counting device is a device used to count red blood cells, white blood cells, or blood platelets.
• Total Protein Biuret Method (FDA Code: CEK / 862.1635)
A total protein test system is a device intended to measure total protein(s) in serum or plasma. Measurements obtained by this device are used in the diagnosis and treatment of a variety of diseases involving the liver, kidney, or bone marrow as well as other metabolic or nutritional disorders.
• Triglycerides Colorimetric Method Test (FDA Code: JGY / 862.1705)
A triglyceride test system is a device intended to measure triglyceride (neutral fat) in serum and plasma. Measurements obtained by this device are used in the diagnosis and treatment of patients with diabetes mellitus, nephrosis, liver obstruction, other diseases involving lipid metabolism, or various endocrine disorders.
• Urea Nitrogen Urease and Glutamic Dehydrogenase Test (FDA Code: CDQ / 862.1770)
A urea nitrogen test system is a device intended to measure urea nitrogen (an end-product of nitrogen metabolism) in whole blood, serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment of certain renal and metabolic diseases.

 Edit or Enhance this Company (223 potential buyers viewed listing,  13 forwarded to manufacturer's website)
Browse Category   |   Alphabetical Products   |   ALL 25,000 Suppliers
HomeBuyAdd FREE ListingAdvertise Medical CompanyMedical Portal