Skype

Semi-Constrained Wrist Prosthesis Suppliers

 EMAIL INQUIRY to  2 suppliers  
Wright Medical Technology, Inc. | Address: 5677 Airline Road, Arlington, Tennessee 38002, USA USA
www.wmt.com | Send Inquiry | Phone: +1-(901)-867-9971, 800-238-7117
FDA Registration: 3012429289  Year Established: 1950  Annual Revenues: USD 100-500 Million  Employee Count: ~1000  Quality: ISO 9002, ISO 9003, CE Certified
Products: Tibial Inserts, Patellar Implants, Metal and Ceramic Liners, All Poly Liners, Femoral Components, Total Shoulder Systems, ...
Wright Medical Technology, Inc. is a global orthopaedic medical device company. Our Advance® Uni-Knee renders normal motion and leads to a longer implant life that delays or prevents the need for more...
 
Zimmer Gmbh | Address: Sulzer Allee 8, Winterthur CH-8404, Switzerland
FDA Registration: 9613350
Products: Small Depth Gauge (FDA Code: HTJ), Depth Gauge (FDA Code: HTJ), Flexible Depth Gauge (FDA Code: HTJ), Uncemented Metal/Polymer Semi-Constrained Hip Prosthesis (FDA Code: LWJ), Cemented Metal/Polymer Semi-Constrained Hip Prosthesis (FDA Code: JDI), Uncemented, Cemented Or Non-Porous Metal/Ceramic/Polymer Semi-Constrained Hip Prosthesis (FDA Code: LZO), ...
Zimmer Gmbh designs and manufactures reconstructive spinal and dental implants, trauma and related orthopedic surgical products. We also offer joint replacement solutions for knee pain and hip pain, a more...
 EMAIL INQUIRY to  2 Semi-Constrained Wrist Prosthesis suppliers  
FDA Code / Regulation: KWM / 888.3800

A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that have either a one-part radial component made of alloys, such as cobalt-chromium-molybdenum, with an ultra-high molecular weight polyethylene bearing surface, or a two-part radial component made of alloys and an ultra-high molecular weight polyethylene ball that is mounted on the radial component with a trunnion bearing. The metallic portion of the two-part radial component is inserted into the radius. These devices have a metacarpal component(s) made of alloys, such as cobalt-chromium-molybdenum. This generic type of device is limited to those prostheses intended for use with bone cement (888.3027).

Classification. Class II.

 BROWSE BY CATEGORY > Orthopedics/Physical Therapy OR VIEW PRODUCTS UNDER Orthopedics/Physical Therapy
Browse Category   |   Alphabetical Products   |   ALL 25,000 Suppliers
HomeBuyAdd FREE ListingAdvertise Medical CompanyMedical Portal