Profile: Skylark Device & Systems Co., Ltd manufactures electro-therapeutic medical products. We produce diagnostic, treatment device, and home health care products. Our diagnostic products include bio-energetic medical instrument, body fat analyzer, bio-energetic medical instrument, body composition analyzer, pulse diagnostic device, meridian health monitor series and tongue diagnostic system. Photon beauty helps to vitalize cells, enhance blood circulation, increase oxygen supply, strengthen skin tissues and improve metabolism and excretion by using natural light wave that transmits into skins and activates light perception cells where energy is absorbed by hemoglobin, proteins, carbohydrates and fats for better skins. The SD-956H ultrasonic massager generates deep heat within body tissue for the treatment of selected medical conditions such as relief of pain, muscle spasms, and joint contractors. It helps muscle rehabilitation, prevent and cure disease, delay aging. Our treatment device products comprise of transcutaneous electro nerve stimulator, electrical neuromuscular stimulator, interferential stimulator, high voltage galvanic stimulator, micro current stimulator, iontophoresis device, combine stimulator, transcutaneous electro nerve stimulator and micro current stimulator.

FDA Registration Number: 8020618
US Agent: Yung-yi Hsu / Bow Window Inc.
Phone: +1-(626)-964-7229

15 Products/Services (Click for related suppliers)  
• Continuous Electronic Thermometer (FDA Code: FLL / 880.2910)
A clinical electronic thermometer is a device used to measure the body temperature of a patient by means of a transducer coupled with an electronic signal amplification, conditioning, and display unit. The transducer may be in a detachable probe with or without a disposable cover.
• Cutaneous Electrode (FDA Code: GXY / 882.1320)
A cutaneous electrode is an electrode that is applied directly to a patient's skin either to record physiological signals (e.g., the electroencephalogram) or to apply electrical stimulation.
• Electric Therapeutic Massager (FDA Code: ISA / 890.5660)
A therapeutic massager is an electrically powered device intended for medical purposes, such as to relieve minor muscle aches and pains.
• Electrical-Powered Muscle Stimulator (FDA Code: IPF / 890.5850)
A powered muscle stimulator is an electrically powered device intended for medical purposes that repeatedly contracts muscles by passing electrical currents through electrodes contacting the affected body area.
• Electroconductive Media (FDA Code: GYB / 882.1275)
Electroconductive media are the conductive creams or gels used with external electrodes to reduce the impedance (resistance to alternating current) of the contact between the electrode surface and the skin.
• Interferential Current Therapy Unit (FDA Code: LIH / 882.5890)
• Iontophoresis Device (FDA Code: EGJ / 890.5525)
An iontophoresis device is a device that is intended to use a direct current to introduce ions of soluble salts or other drugs into the body and induce sweating for use in the diagnosis of cystic fibrosis or for other uses if the labeling of the drug intended for use with the device bears adequate directions for the device's use with that drug. When used in the diagnosis of cystic fibrosis, the sweat is collected and its composition and weight are determined.
• Micro-current Stimulator
• Non-Implantable Electrical Stimulator (FDA Code: KPI / 876.5320)
A nonimplanted electrical continence device is a device that consists of a pair of electrodes on a plug or a pessary that are connected by an electrical cable to a battery-powered pulse source. The plug or pessary is inserted into the rectum or into the vagina and used to stimulate the muscles of the pelvic floor to maintain urinary or fecal continence. When necessary, the plug or pessary may be removed by the user. This device excludes an AC-powered nonimplanted electrical continence device and the powered vaginal muscle stimulator for therapeutic use (884.5940).
• Over-The-Counter Transcutaneous Nerve Stimulator (FDA Code: NUH / 882.5890)
• Therapeutic Heating Infrared Lamp (FDA Code: ILY / 890.5500)
An infrared lamp is a device intended for medical purposes that emits energy at infrared frequencies (approximately 700 nanometers to 50,000 nanometers) to provide topical heating.
• TInfrared Light (FDA Code: ILY / 890.5500)
• Transcutaneous Nerve Stimulator for Pain Relief (FDA Code: GZJ / 882.5890)
• Ultrasonic Diathermy for use in Applying Therapeutic Deep Heat (FDA Code: IMI / 890.5300)
An ultrasonic diathermy for use in applying therapeutic deep heat for selected medical conditions is a device that applies to specific areas of the body ultrasonic energy at a frequency beyond 20 kilohertz and that is intended to generate deep heat within body tissues for the treatment of selected medical conditions such as relief of pain, muscle spasms, and joint contractures, but not for the treatment of malignancies.