Skype

Spectrum Laboratories, Inc.

Click Here To EMAIL INQUIRY
Web: http://www.spectrapor.com
E-Mail:
Address: 18617 S Broadwick St, Rancho Dominguez, California 90220, USA
Phone: +1-(310)-885-4600, 800-634-3300 | Fax: +1-(310)-885-4666 | Map/Directions >>
 
 

Profile: Spectrum Laboratories, Inc. provides disposable hollow fiber modules that are used primarily for biological separations, molecular separations and management of cell lines. The Spectra/Por® microdialyzer is designed for the simultaneous dialysis of multiple micro-volume samples separated from a common dialysate chamber by a single membrane frame to provide uniform conditions for all samples. The dialysate chamber can either accommodate a magnetic stir bar for agitation in static mode or be connected via female luer fittings for circulation of a larger buffer volume to maintain a more effective concentration gradient in dynamic dialysis. The microdialyzer multi-layer design consists of a dialysate chamber, membrane frame & multi-well sample plate clamped together (bolted for 96-well) with sample reservoir and cover plates to protect the samples.

The company was founded in 1970, has revenues of USD 10-25 Million, has ~120 employees and is ISO 9000 certified. NASDAQ:SPTM (SEC Filings)

FDA Registration Number: 2025136

1 to 50 of 90 Products/Services (Click for related suppliers)  Page: [1] 2 >> Next 50 Results
• Adhesive Bandages (FDA Code: KGX / 880.5240)
A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists of a strip of fabric material or plastic, coated on one side with an adhesive, and may include a pad of surgical dressing without a disinfectant. The device is used to cover and protect wounds, to hold together the skin edges of a wound, to support an injured part of the body, or to secure objects to the skin.
• Adult-Pediatric Volumetric Infusion Pumps
• Ambulatory Infusion Pumps
• Anesthesia Infusion Pump Tubing
• Anesthetic Infusion Pump (FDA Code: FRN / 880.5725)
An infusion pump is a device used in a health care facility to pump fluids into a patient in a controlled manner. The device may use a piston pump, a roller pump, or a peristaltic pump and may be powered electrically or mechanically. The device may also operate using a constant force to propel the fluid through a narrow tube which determines the flow rate. The device may include means to detect a fault condition, such as air in, or blockage of, the infusion line and to activate an alarm.
• Antibiotic Medicated Bandages
• Automatic Delivery Peritoneal System (FDA Code: FKX / 876.5630)
(1) A peritoneal dialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions, and that consists of a peritoneal access device, an administration set for peritoneal dialysis, a source of dialysate, and, in some cases, a water purification mechanism. After the dialysate is instilled into the patient's peritoneal cavity, it is allowed to dwell there so that undesirable substances from the patient's blood pass through the lining membrane of the peritoneal cavity into this dialysate. These substances are then removed when the dialysate is drained from the patient. The peritoneal dialysis system may regulate and monitor the dialysate temperature, volume, and delivery rate together with the time course of each cycle of filling, dwell time, and draining of the peritoneal cavity or manual controls may be used. This generic device includes the semiautomatic and the automatic peritoneal delivery system.
• Bandages Adhesive Plastic
• Batteries & Battery Assemblies for Infusion Pumps
• Bulb Irrigation Syringe
• Bulb Syringes
• Casting Materials
• Casting Materials and Equipment, Casting Stands
• Clinical Sample Concentrator (FDA Code: JJH / 862.2310)
A clinical sample concentrator is a device intended to concentrate (by dialysis, evaporation, etc.) serum, urine, cerebrospinal fluid, and other body fluids before the fluids are analyzed.
• Cohesive Bandages
• Constant-flow Infusion Pump
• Disposable Irrigation Bulb Syringe
• Disposable Surgical Drape (FDA Code: KKX / 878.4370)
A surgical drape and drape accessories is a device made of natural or synthetic materials intended to be used as a protective patient covering, such as to isolate a site of surgical incision from microbial and other contamination. The device includes a plastic wound protector that may adhere to the skin around a surgical incision or be placed in a wound to cover its exposed edges, and a latex drape with a self-retaining finger cot that is intended to allow repeated insertion of the surgeon's finger into the rectum during performance of a transurethral prostatectomy.
• Dressings, Bandages, Gauze
• Dual-Channel Volumetric Infusion Pump
• Elastic Bandages (FDA Code: FQM / 880.5075)
An elastic bandage is a device consisting of either a long flat strip or a tube of elasticized material that is used to support and compress a part of a patient's body.
• Elastic Cohesive Bandages
• Elastic Tubular Bandages
• Ergonomic Hospital Supplies
• Eye Bandages
• Fiberglass Casting Material
• Flotation Cushion (FDA Code: KIC / 890.3175)
A flotation cushion is a device intended for medical purposes that is made of plastic, rubber, or other type of covering, that is filled with water, air, gel, mud, or any other substance allowing a flotation media, used on a seat to lessen the likelihood of skin ulcers.
• Frozen Donor Tissue Storage Container (FDA Code: LPZ)
• Gas Filter
• Gas Filtering Tubes
• Gauze Bandages
• General Bandages
• General Medical Supplies
• General Orthopedic Supplies
• General Surgical Aids
• Hollow Fiber Capillary Dialyzer (FDA Code: FJI / 876.5820)
A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.
• Hospital Supplies
• Hydrophilic Membrane Filter
• Hydrophobic Membrane Filter
• Infusion Line Filter (FDA Code: FPB / 880.5440)
An intravascular administration set is a device used to administer fluids from a container to a patient's vascular system through a needle or catheter inserted into a vein. The device may include the needle or catheter, tubing, a flow regulator, a drip chamber, an infusion line filter, an I.V. set stopcock, fluid delivery tubing, connectors between parts of the set, a side tube with a cap to serve as an injection site, and a hollow spike to penetrate and connect the tubing to an I.V. bag or other infusion fluid container.
• Infusion Pump Analysis System
• Infusion Pump Repair
• Infusion Pump Service Parts
• Infusion Pump Stands
• Infusion Pump Tester
• Infusion Pumps, Ambulatory Pumps
• IV Medication Delivery Systems, volumetric infusion pumps
• IV Stand Accessories, Multi-Infusion Pump
• Laboratory Dialyzer
• Laboratory Equipment

 Edit or Enhance this Company (3196 potential buyers viewed listing,  434 forwarded to manufacturer's website)
Browse Category   |   Alphabetical Products   |   ALL 25,000 Suppliers
HomeBuyAdd FREE ListingAdvertise Medical CompanyMedical Portal