Profile: Surgik Lc manufactures surgical devices. Our products include absorbable sutures, non-absorbable sutures and electrosurgical. The catgut is an absorbable surgical suture. Our needles are made of special surgical grade 400 series stainless steel to provide both strength and flexibility. We provide polyglycolic acid suture, which is a braided coated synthetic absorbable, surgical suture composed of glycolide, a nonantigenic and nonpyrogenic polimer. This is indicated for use in general soft tissue approximation and/or ligation, including use in ophthalmic procedures. The polyester suture is a non-absorbable, sterile, surgical suture composed of polyethylene terepthalate. This polyester suture elicits a minimal acute inflammatory reaction in tissues. We offer an array of electrosurgical devices include pencils, ground pads, electrodes, suction coagulators, bipolar and monopolar forceps, cords and adapters.
FDA Registration Number: 3006408264
29 Products/Services (Click for related suppliers)
|
• Absorbable Sutures (FDA Code: GAK / 878.4830) An absorbable surgical gut suture, both plain and chromic, is an absorbable, sterile, flexible thread prepared from either the serosal connective tissue layer of beef (bovine) or the submucosal fibrous tissue of sheep (ovine) intestine, and is intended for use in soft tissue approximation. |
• Automatic Surgical Stapler (FDA Code: GAG / 878.4800) A manual surgical instrument for general use is a nonpowered, hand-held, or hand-manipulated device, either reusable or disposable, intended to be used in various general surgical procedures. The device includes the applicator, clip applier, biopsy brush, manual dermabrasion brush, scrub brush, cannula, ligature carrier, chisel, clamp, contractor, curette, cutter, dissector, elevator, skin graft expander, file, forceps, gouge, instrument guide, needle guide, hammer, hemostat, amputation hook, ligature passing and knot-tying instrument, knife, blood lancet, mallet, disposable or reusable aspiration and injection needle, disposable or reusable suturing needle, osteotome, pliers, rasp, retainer, retractor, saw, scalpel blade, scalpel handle, one-piece scalpel, snare, spatula, stapler, disposable or reusable stripper, stylet, suturing apparatus for the stomach and intestine, measuring tape, and calipers. A surgical instrument that has specialized uses in a specific medical specialty is classified in separate regulations in parts 868 through 892. |
• Circular Staplers |
• Electrosurgical Accessories, Arthroscopy Electrodes |
• Electrosurgical Cutting and Coagulation Device (FDA Code: GEI / 878.4400) An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current. |
• Electrosurgical Pencils |
• Forceps, Bipolar |
• Laparoscopic Electrodes |
• Laparoscopic Needle Holder/Scissors |
• Laparoscopy, Hook Scissors |
• Linear Cutter Staplers |
• Linear Staplers |
• Non-Absorbable Nylon Sutures |
• Non-Absorbable Silk Sutures |
• Non-Absorbable Sutures (FDA Code: GAO / 878.4495) |
• Non-Absorbable Sutures, Polyester |
• Non-Absorbable Sutures, Polypropelene |
• Non-Stick Bipolar Forceps |
• Polyamide Synthetic Non-Absorbable Suture (FDA Code: GAR / 878.5020) Nonabsorbable polyamide surgical suture is a nonabsorbable, sterile, flexible thread prepared from long-chain aliphatic polymers Nylon 6 and Nylon 6,6 and is indicated for use in soft tissue approximation. The polyamide surgical suture meets United States Pharmacopeia (U.S.P.) requirements as described in the U.S.P. monograph for nonabsorbable surgical sutures; it may be monofilament or multifilament in form; it may be provided uncoated or coated; and it may be undyed or dyed with an appropriate FDA listed color additive. Also, the suture may be provided with or without a standard needle attached. |
• Polydioxanone Absorbable Surgical Suture (FDA Code: NEW / 878.4840) An absorbable polydioxanone surgical suture is an absorbable, flexible, sterile, monofilament thread prepared from polyester polymer poly (p-dioxanone) and is intended for use in soft tissue approximation, including pediatric cardiovascular tissue where growth is expected to occur, and ophthalmic surgery. It may be coated or uncoated, undyed or dyed, and with or without a standard needle attached. |
• Polydioxanone Sutures, Absorbable |
• Polyethylene Synthetic Non-Absorbable Suture (FDA Code: GAT / 878.5000) Nonabsorbable poly(ethylene terephthalate) surgical suture is a multifilament, nonabsorbable, sterile, flexible thread prepared from fibers of high molecular weight, long-chain, linear polyesters having recurrent aromatic rings as an integral component and is indicated for use in soft tissue approximation. The poly(ethylene terephthalate) surgical suture meets U.S.P. requirements as described in the U.S.P. Monograph for Nonabsorbable Surgical Sutures; it may be provided uncoated or coated; and it may be undyed or dyed with an appropriate FDA listed color additive. Also, the suture may be provided with or without a standard needle attached. |
• Polyglycolic Acid Sutures, Absorbable |
• Polyglycolic Acid Synthetic Absorbable Suture (FDA Code: GAM / 878.4493) An absorbable poly(glycolide/l-lactide) surgical suture (PGL suture) is an absorbable sterile, flexible strand as prepared and synthesized from homopolymers of glycolide and copolymers made from 90 percent glycolide and 10 percentl-lactide, and is indicated for use in soft tissue approximation. A PGL suture meets United States Pharmacopeia (U.S.P.) requirements as described in the U.S.P. "Monograph for Absorbable Surgical Sutures;" it may be monofilament or multifilament (braided) in form; it may be uncoated or coated; and it may be undyed or dyed with an FDA-approved color additive. Also, the suture may be provided with or without a standard needle attached. |
• Polypropylene Synthetic Non-Absorbable Suture (FDA Code: GAW / 878.5010) Nonabsorbable polypropylene surgical suture is a monofilament, nonabsorbable, sterile, flexible thread prepared from long-chain polyolefin polymer known as polypropylene and is indicated for use in soft tissue approximation. The polypropylene surgical suture meets United States Pharmacopeia (U.S.P.) requirements as described in the U.S.P. Monograph for Nonabsorbable Surgical Sutures; it may be undyed or dyed with an FDA approved color additive; and the suture may be provided with or without a standard needle attached. |
• Removable Skin Staple (FDA Code: GDT / 878.4760) A removable skin staple is a staple-like device intended to connect external tissues temporarily to aid healing. It is not absorbable. |
• Silk Non-Absorbable Suture (FDA Code: GAP / 878.5030) Natural nonabsorbable silk surgical suture is a nonabsorbable, sterile, flexible multifilament thread composed of an organic protein called fibroin. This protein is derived from the domesticated speciesBombyx mori (B. mori ) of the familyBombycidae. Natural nonabsorbable silk surgical suture is indicated for use in soft tissue approximation. Natural nonabsorbable silk surgical suture meets the United States Pharmacopeia (U.S.P.) monograph requirements for Nonabsorbable Surgical Suture (class I). Natural nonabsorbable silk surgical suture may be braided or twisted; it may be provided uncoated or coated; and it may be undyed or dyed with an FDA listed color additive. |
• Stomach and Intestinal Suture Apparatus (FDA Code: FHM / 878.4800) |
• Surgical Staple Applier (FDA Code: GEF / 878.4800) |