Profile: Synthes (USA) is a medical device company. We develop, produce and market instruments, implants & biomaterials for the surgical fixation, correction and regeneration of the human skeleton & its soft tissues. We offer a variety of programs and services to help hospitals better manage the purchasing process, from inventory management to data cleansing and electronic pricing systems. Our trauma implants and instruments are used for the surgical treatment of fractures, deformities and tumors of the long bones (arms & legs),the shoulder, hand,foot and the pelvis. Our product portfolio comprises of plates, screws, cannulated screws, intramedullary nails, a comprehensive range of external fixators, and products for the hip & condyles. We offer surgeons a broad range of implants and instruments for the treatment of fractures, tumors, deformities, and degenerative diseases affecting the spine.
The company was founded in 1974, has revenues of > USD 1 Billion, has ~9000 employees. SWF:SYST (SEC Filings)
FDA Registration Number: 3003506883
• Rib Replacement Prosthesis (FDA Code: MDI) |
• Rib Rongeurs (FDA Code: HTX / 888.4540) An orthopedic manual surgical instrument is a nonpowered hand-held device intended for medical purposes to manipulate tissue, or for use with other devices in orthopedic surgery. This generic type of device includes the cerclage applier, awl, bender, drill brace, broach, burr, corkscrew, countersink, pin crimper, wire cutter, prosthesis driver, extractor, file, fork, needle holder, impactor, bending or contouring instrument, compression instrument, passer, socket positioner, probe, femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. |
• Ruler and Caliper (FDA Code: FTY / 878.4800) A manual surgical instrument for general use is a nonpowered, hand-held, or hand-manipulated device, either reusable or disposable, intended to be used in various general surgical procedures. The device includes the applicator, clip applier, biopsy brush, manual dermabrasion brush, scrub brush, cannula, ligature carrier, chisel, clamp, contractor, curette, cutter, dissector, elevator, skin graft expander, file, forceps, gouge, instrument guide, needle guide, hammer, hemostat, amputation hook, ligature passing and knot-tying instrument, knife, blood lancet, mallet, disposable or reusable aspiration and injection needle, disposable or reusable suturing needle, osteotome, pliers, rasp, retainer, retractor, saw, scalpel blade, scalpel handle, one-piece scalpel, snare, spatula, stapler, disposable or reusable stripper, stylet, suturing apparatus for the stomach and intestine, measuring tape, and calipers. A surgical instrument that has specialized uses in a specific medical specialty is classified in separate regulations in parts 868 through 892. |
• Screwdriver (FDA Code: HXX / 888.4540) |
• Simple Powered Trephines & Accessories (FDA Code: HBE / 882.4310) Powered simple cranial drills, burrs, trephines, and their accessories are bone cutting and drilling instruments used on a patient's skull. The instruments are used with a power source but do not have a clutch mechanism to disengage the tip after penetrating the skull. |
• Single Component Fixation Appliance (FDA Code: KTW / 888.3030) Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system. |
• Small Depth Gauge (FDA Code: HTJ / 888.4300) A depth gauge for clinical use is a measuring device intended for various medical purposes, such as to determine the proper length of screws for fastening the ends of a fractured bone. |
• Smooth Fixation Pin (FDA Code: HTY / 888.3040) A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system. |
• Spinal Fixation Device Implant (FDA Code: JDN / 888.3060) A spinal intervertebral body fixation orthosis is a device intended to be implanted made of titanium. It consists of various vertebral plates that are punched into each of a series of vertebral bodies. An eye-type screw is inserted in a hole in the center of each of the plates. A braided cable is threaded through each eye-type screw. The cable is tightened with a tension device and it is fastened or crimped at each eye-type screw. The device is used to apply force to a series of vertebrae to correct "sway back," scoliosis (lateral curvature of the spine), or other conditions. |
• Spinal Interlaminal Fixation Appliance (FDA Code: KWP / 888.3050) A spinal interlaminal fixation orthosis is a device intended to be implanted made of an alloy, such as stainless steel, that consists of various hooks and a posteriorly placed compression or distraction rod. The device is implanted, usually across three adjacent vertebrae, to straighten and immobilize the spine to allow bone grafts to unite and fuse the vertebrae together. The device is used primarily in the treatment of scoliosis (a lateral curvature of the spine), but it also may be used in the treatment of fracture or dislocation of the spine, grades 3 and 4 of spondylolisthesis (a dislocation of the spinal column), and lower back syndrome. |
• Spinal Intervertebral Body Fixation Appliance (FDA Code: KWQ / 888.3060) |
• Spinal Pedicle Fixation Orthosis (FDA Code: MNI / 888.3070) Pedicle screw spinal systems are multiple component devices, made from a variety of materials, including alloys such as 316L stainless steel, 316LVM stainless steel, 22Cr-13Ni-5Mn stainless steel, Ti-6Al-4V, and unalloyed titanium, that allow the surgeon to build an implant system to fit the patient's anatomical and physiological requirements. Such a spinal implant assembly consists of a combination of anchors (e.g., bolts, hooks, and/or screws); interconnection mechanisms incorporating nuts, screws, sleeves, or bolts; longitudinal members (e.g., plates, rods, and/or plate/rod combinations); and/or transverse connectors. |
• Spinal Pedicle Fixation Orthosis For Degenerative Disc Disease (FDA Code: NKB / 888.3070) |
• Spinal Vertebral Body Replacement Device (FDA Code: MQP / 888.3060) |
• Spondylolisthesis Spinal Fixation Orthosis (FDA Code: MNH / 888.3070) |
• Stainless Steel Surgical Wire |
• Surgical Bit (FDA Code: GFG / 878.4820) Surgical instrument motors and accessories are AC-powered, battery-powered, or air-powered devices intended for use during surgical procedures to provide power to operate various accessories or attachments to cut hard tissue or bone and soft tissue. Accessories or attachments may include a bur, chisel (osteotome), dermabrasion brush, dermatome, drill bit, hammerhead, pin driver, and saw blade. |
• Surgical Hammer (FDA Code: FZY / 878.4800) |
• Surgical Instrument Tray (FDA Code: FSM / 878.4800) |
• Surgical Mesh (FDA Code: FTM / 878.3300) Surgical mesh is a metallic or polymeric screen intended to be implanted to reinforce soft tissue or bone where weakness exists. Examples of surgical mesh are metallic and polymeric mesh for hernia repair, and acetabular and cement restrictor mesh used during orthopedic surgery. |
• Surgical Pliers (FDA Code: HTC / 878.4800) |
• Surgical Retractor (FDA Code: GAD / 878.4800) |
• Surgical Retractor Systems (FDA Code: GAD / 878.4800) |
• Surgical Stylet (FDA Code: GAH / 878.4800) |
• Surgical Wire (FDA Code: LRN / 888.3030) |
• Tamps (FDA Code: HXG / 888.4540) |
• Templates (FDA Code: HWT / 888.4800) A template for clinical use is a device that consists of a pattern or guide intended for medical purposes, such as selecting or positioning orthopedic implants or guiding the marking of tissue before cutting. |
• Threaded Fixation Pin (FDA Code: JDW / 888.3040) |
• Uncemented Metal/Polymer Shoulder Prosthesis (FDA Code: MBF / 888.3670) A shoulder joint metal/polymer/metal nonconstrained or semi-constrained porous-coated uncemented prosthesis is a device intended to be implanted to replace a shoulder joint. The device limits movement in one or more planes. It has no linkage across-the-joint. This generic type of device includes prostheses that have a humeral component made of alloys such as cobalt-chromium-molybdenum (Co-Cr-Mo) and titanium-aluminum-vanadium (Ti-6Al-4V) alloys, and a glenoid resurfacing component made of ultra-high molecular weight polyethylene, or a combination of an articulating ultra-high molecular weight bearing surface fixed in a metal shell made of alloys such as Co-Cr-Mo and Ti-6Al-4V. The humeral component and glenoid backing have a porous coating made of, in the case of Co-Cr-Mo components, beads of the same alloy or commercially pure titanium powder, and in the case of Ti-6Al-4V components, beads or fibers of commercially pure titanium or Ti-6Al-4V alloy, or commercially pure titanium powder. The porous coating has a volume porosity between 30 and 70 percent, an average pore size between 100 and 1,000 microns, interconnecting porosity, and a porous coating thickness between 500 and 1,500 microns. This generic type of device is designed to achieve biological fixation to bone without the use of bone cement. |
• Wire Cutters (FDA Code: HXZ / 888.4540) |
• Wire Twisters (FDA Code: HXS / 888.4540) |
• Wrench (FDA Code: HXC / 888.4540) |