Skype

Technical Products, Inc.

Click Here To EMAIL INQUIRY
Contact: Mr. Eric Thompson B.S.N. - VP & Manager Sales
Web: http://www.tpi-ga.com
E-Mail:
Address: 805 Marathon Parkway, Suite 150, Lawrenceville, Georgia 30045, USA
Phone: +1-(770)-236-8452, 800-226-8434 | Fax: +1-(770)-236-8453 | Map/Directions >>
 
 

Profile: Technical Products, Inc. provides custom medical device development and a range of medical & surgical products to hospitals, clinics, medical centers & medical practitioners. Our latex-free silicone products include medical grade silicone sheeting that are available as reinforced, non-reinforced, sterile and non-sterile, as well as radiopaque. We also offer gel sheeting, as well as silicone blocks, tubing, round rods, oval rods, and incision drains which are used in ear, nose, and throat surgical procedures.

The company was founded in 1967, has ~20 employees and is ISO 9001 certified.

FDA Registration Number: 1061771

30 Products/Services (Click for related suppliers)  
• Adjustable Esophageal Reconstruction Tubes
• Catheter Connector (FDA Code: GCD / 878.4200)
An introduction/drainage catheter is a device that is a flexible single or multilumen tube intended to be used to introduce nondrug fluids into body cavities other than blood vessels, drain fluids from body cavities, or evaluate certain physiologic conditions. Examples include irrigation and drainage catheters, pediatric catheters, peritoneal catheters (including dialysis), and other general surgical catheters. An introduction/drainage catheter accessory is intended to aid in the manipulation of or insertion of the device into the body. Examples of accessories include adaptors, connectors, and catheter needles.
• Collagen Punctum Plugs
• ENT Manual Surgical Instrument (FDA Code: LRC / 874.4420)
• Extended Duration Punctum Plugs
• Foley Catheters
• Incision and Drainage Kit
• Irrigation Catheter (FDA Code: GBX / 878.4200)
• Lacrimal Punctum Plug
• Malecot Catheters (FDA Code: FEW / 876.5090)
A suprapubic urological catheter and accessories is a flexible tubular device that is inserted through the abdominal wall into the urinary bladder with the aid of a trocar and cannula. The device is used to pass fluids to and from the urinary tract. This generic type of device includes the suprapubic catheter and tube, Malecot catheter, catheter punch instrument, suprapubic drainage tube, and the suprapubic cannula and trocar.
• Multiple Lumen Catheter (FDA Code: GBP / 878.4200)
• Nasal Vent Tubes
• Non-Powered Portable Single Patient Suction Apparatus (FDA Code: GCY / 878.4680)
A nonpowered, single patient, portable suction apparatus is a device that consists of a manually operated plastic, disposable evacuation system intended to provide a vacuum for suction drainage of surgical wounds.
• Ophthalmic Conformer (FDA Code: HQN / 886.3130)
An ophthalmic conformer is a device usually made of molded plastic intended to be inserted temporarily between the eyeball and eyelid to maintain space in the orbital cavity and prevent closure or adhesions during the healing process following surgery. ]
• Passive Tendon Prosthesis (FDA Code: HXA / 888.3025)
A passive tendon prosthesis is a device intended to be implanted made of silicon elastomer or a polyester reinforced medical grade silicone elastomer intended for use in the surgical reconstruction of a flexor tendon of the hand. The device is implanted for a period of 2 to 6 months to aid growth of a new tendon sheath. The device is not intended as a permanent implant nor to function as a replacement for the ligament or tendon nor to function as a scaffold for soft tissue ingrowth.
• Polymeric Surgical Mesh (FDA Code: FTL / 878.3300)
Surgical mesh is a metallic or polymeric screen intended to be implanted to reinforce soft tissue or bone where weakness exists. Examples of surgical mesh are metallic and polymeric mesh for hernia repair, and acetabular and cement restrictor mesh used during orthopedic surgery.
• Punctum Plug (FDA Code: LZU)
• Punctum Plugs (Punctal Plugs)
• Radiopaque T-Tubes
• Silastic Elastomer
• Silicon Elastomer ENT Synthetic-PIFE Polymer (FDA Code: ESH / 874.3620)
Ear, nose, and throat synthetic polymer material is a device material that is intended to be implanted for use as a space-occupying substance in the reconstructive surgery of the head and neck. The device is used, for example, in augmentation rhinoplasty and in tissue defect closures in the esophagus. The device is shaped and formed by the suregon to conform to the patient's needs. This generic type of device is made of material such as polyamide mesh or foil and porous polyethylene.
• Silicone Block Elastomer (FDA Code: MIB / 874.3620)
• Silicone Penrose Drainage Tube
• Silicone Punctum Plugs
• smaller punctum plugs
• Tendon Spacer
• Tracheal Cannulas with Speaking Value
• Tracheal Speaking Valve
• Tracheal Tube with/without Connector (FDA Code: BTR / 868.5730)
A tracheal tube is a device inserted into a patient's trachea via the nose or mouth and used to maintain an open airway.
• Valve Introducers

 Edit or Enhance this Company (309 potential buyers viewed listing,  78 forwarded to manufacturer's website)
Browse Category   |   Alphabetical Products   |   ALL 25,000 Suppliers
HomeBuyAdd FREE ListingAdvertise Medical CompanyMedical Portal