Profile: Terumo Corporation manufactures & distributes medical products & equipment that include pharmaceuticals, nutritional food supplement, blood bags, disposable medical devices, cardiovascular systems, peritoneal dialysis, blood glucose monitoring system, medical electronic and digital thermometers. Our melodion thermometer indicates a patient's body temperature with a melody of moderate sound range. Our medical electronic products includes infusion pump, syringe pump, enteral feeding pump, electronic thermometer, and electronic sphygmomanometer. Our cardiovascular systems products are used when open-heart surgery requires stopping the patient's heart. They essentially take over the role of the heart in supplying blood to the body, and the lungs in exchanging gases. These products include oxygenator, roller pump, centrifugal pump and blood gas monitor.

FDA Registration Number: 9681834
US Agent: Dina Justice / Terumo Medical Corp.
Phone: +1-(410)-392-7226  Fax: +1-(410)-398-6079  E-Mail:

1 to 50 of 77 Products/Services (Click for related suppliers)  Page: [1] 2 >> Next 50 Results
• Allergy Syringes/Trays
• Alpha-1-Antitrypsin (FDA Code: DEM / 866.5130)
Analpha -1-antitrypsin immunological test system is a device that consists of the reagents used to measure by immunochemical techniques thealpha -1-antitrypsin (a plasma protein) in serum, other body fluids, and tissues. The measurements aid in the diagnosis of several conditions including juvenile and adult cirrhosis of the liver. In addition,alpha -1-antitrypsin deficiency has been associated with pulmonary emphysema.
• Antistick Syringe (FDA Code: MEG / 880.5860)
A piston syringe is a device intended for medical purposes that consists of a calibrated hollow barrel and a movable plunger. At one end of the barrel there is a male connector (nozzle) for fitting the female connector (hub) of a hypodermic single lumen needle. The device is used to inject fluids into, or withdraw fluids from, the body.
• Arterial Line Cardiopulmonary Bypass Blood Filter (FDA Code: DTM / 870.4260)
A cardiopulmonary bypass arterial line blood filter is a device used as part of a gas exchange (oxygenator) system to filter nonbiologic particles and emboli (blood clots or pieces of foreign material flowing in the bloodstream which will obstruct circulation by blocking a vessel) out of the blood. It is used in the arterial return line.
• Artery Vascular Clamp (FDA Code: DXC / 870.4450)
A vascular clamp is a surgical instrument used to occlude a blood vessel temporarily.
• Automatic Delivery Peritoneal System (FDA Code: FKX / 876.5630)
(1) A peritoneal dialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions, and that consists of a peritoneal access device, an administration set for peritoneal dialysis, a source of dialysate, and, in some cases, a water purification mechanism. After the dialysate is instilled into the patient's peritoneal cavity, it is allowed to dwell there so that undesirable substances from the patient's blood pass through the lining membrane of the peritoneal cavity into this dialysate. These substances are then removed when the dialysate is drained from the patient. The peritoneal dialysis system may regulate and monitor the dialysate temperature, volume, and delivery rate together with the time course of each cycle of filling, dwell time, and draining of the peritoneal cavity or manual controls may be used. This generic device includes the semiautomatic and the automatic peritoneal delivery system.
• Blood & Components Collection Container (FDA Code: KSR / 864.9100)
An empty container for the collection and processing of blood and blood components is a device intended for medical purposes that is an empty plastic bag or plastic or glass bottle used to collect, store, or transfer blood and blood components for further processing.
• Blood Bank Supplies (FDA Code: KSS / 864.9050)
Blood bank supplies are general purpose devices intended for in vitro use in blood banking. This generic type of device includes products such as blood bank pipettes, blood grouping slides, blood typing tubes, blood typing racks, and cold packs for antisera reagents. The device does not include articles that are licensed by the Center for Biologics Evaluation and Research of the Food and Drug Administration.
• Blood Collect Tubes
• Blood Collection Systems (FDA Code: JKA / 862.1675)
A blood specimen collection device is a device intended for medical purposes to collect and to handle blood specimens and to separate serum from nonserum (cellular) components prior to further testing. This generic type device may include blood collection tubes, vials, systems, serum separators, blood collection trays, or vacuum sample tubes.
• Blood Mixing and Weighing Device (FDA Code: KSQ / 864.9195)
A blood mixing device is a device intended for medical purposes that is used to mix blood or blood components by agitation. A blood weighing device is a device intended for medical purposes that is used to weigh blood or blood components as they are collected.
• Blood Transfer Unit (FDA Code: KSB / 864.9875)
A transfer set is a device intended for medical purposes that consists of a piece of tubing with suitable adaptors used to transfer blood or plasma from one container to another.
• Blood Transfusion Microfilter (FDA Code: CAK / 880.5440)
An intravascular administration set is a device used to administer fluids from a container to a patient's vascular system through a needle or catheter inserted into a vein. The device may include the needle or catheter, tubing, a flow regulator, a drip chamber, an infusion line filter, an I.V. set stopcock, fluid delivery tubing, connectors between parts of the set, a side tube with a cap to serve as an injection site, and a hollow spike to penetrate and connect the tubing to an I.V. bag or other infusion fluid container.
• Blood Transfusion Sets (FDA Code: BRZ / 880.5440)
• Cardiopulmonary Bypass Accessories (FDA Code: KRI / 870.4200)
Cardiopulmonary bypass accessory equipment is a device that has no contact with blood and that is used in the cardiopulmonary bypass circuit to support, adjoin, or connect components, or to aid in the setup of the extracorporeal line, e.g., an oxygenator mounting bracket or system-priming equipment.
• Cardiopulmonary Bypass Adaptor (FDA Code: DTL / 870.4290)
A cardiopulmonary bypass adaptor, stopcock, manifold, or fitting is a device used in cardiovascular diagnostic, surgical, and therapeutic applications to interconnect tubing, catheters, or other devices.
• Cardiopulmonary Bypass Blood Reservoir (FDA Code: DTN / 870.4400)
A cardiopulmonary bypass blood reservoir is a device used in conjunction with short-term extracorporeal circulation devices to hold a reserve supply of blood in the bypass circulation.
• Cardiopulmonary Bypass Bubble Detector (FDA Code: KRL / 870.4205)
A cardiopulmonary bypass bubble detector is a device used to detect bubbles in the arterial return line of the cardiopulmonary bypass circuit.
• Cardiopulmonary Bypass Defoamer (FDA Code: DTP / 870.4230)
A cardiopulmonary bypass defoamer is a device used in conjunction with an oxygenator during cardiopulmonary bypass surgery to remove gas bubbles from the blood.
• Cardiopulmonary Bypass Heat Exchanger (FDA Code: DTR / 870.4240)
A cardiopulmonary bypass heat exchanger is a device, consisting of a heat exchange system used in extracorporeal circulation to warm or cool the blood or perfusion fluid flowing through the device.
• Cardiopulmonary Bypass Oxygenator (FDA Code: DTZ / 870.4350)
A cardiopulmonary bypass oxygenator is a device used to exchange gases between blood and a gaseous environment to satisfy the gas exchange needs of a patient during open-heart surgery.
• Cardiopulmonary Bypass Vascular Catheter (FDA Code: DWF / 870.4210)
A cardiopulmonary bypass vascular catheter, cannula, or tubing is a device used in cardiopulmonary surgery to cannulate the vessels, perfuse the coronary arteries, and to interconnect the catheters and cannulas with an oxygenator. The device includes accessory bypass equipment.
• Cardiopulmonary Level Sensing Monitor and Control (FDA Code: DTW / 870.4340)
A cardiopulmonary bypass level sensing monitor and/or control is a device used to monitor and/or control the level of blood in the blood reservoir and to sound an alarm when the level falls below a predetermined value.
• Catheter Connector (FDA Code: GCD / 878.4200)
An introduction/drainage catheter is a device that is a flexible single or multilumen tube intended to be used to introduce nondrug fluids into body cavities other than blood vessels, drain fluids from body cavities, or evaluate certain physiologic conditions. Examples include irrigation and drainage catheters, pediatric catheters, peritoneal catheters (including dialysis), and other general surgical catheters. An introduction/drainage catheter accessory is intended to aid in the manipulation of or insertion of the device into the body. Examples of accessories include adaptors, connectors, and catheter needles.
• Catheter Introducers (FDA Code: DYB / 870.1340)
A catheter introducer is a sheath used to facilitate placing a catheter through the skin into a vein or artery.
• Catheter Introducers, MULLINS
• Catheter Introducers, Mullins Design
• Cholangiography Catheters (FDA Code: GBZ / 878.4200)
• Continuous Electronic Thermometer (FDA Code: FLL / 880.2910)
A clinical electronic thermometer is a device used to measure the body temperature of a patient by means of a transducer coupled with an electronic signal amplification, conditioning, and display unit. The transducer may be in a detachable probe with or without a disposable cover.
• Continuous Flush Catheter (FDA Code: KRA / 870.1210)
A continuous flush catheter is an attachment to a catheter-transducer system that permits continuous intravascular flushing at a slow infusion rate for the purpose of eliminating clotting, back-leakage, and waveform damping.
• Crimp Pliers (FDA Code: FJY / 876.5540)
A blood access device and accessories is a device intended to provide access to a patient's blood for hemodialysis or other chronic uses. When used in hemodialysis, it is part of an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and provides access to a patient's blood for hemodialysis. The device includes implanted blood access devices, nonimplanted blood access devices, and accessories for both the implanted and nonimplanted blood access devices.
• Diagnostic Intravascular Catheter (FDA Code: DQO / 870.1200)
An intravascular diagnostic catheter is a device used to record intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among others.
• Disposable Aspiration and Injection Needle (FDA Code: GAA / 878.4800)
A manual surgical instrument for general use is a nonpowered, hand-held, or hand-manipulated device, either reusable or disposable, intended to be used in various general surgical procedures. The device includes the applicator, clip applier, biopsy brush, manual dermabrasion brush, scrub brush, cannula, ligature carrier, chisel, clamp, contractor, curette, cutter, dissector, elevator, skin graft expander, file, forceps, gouge, instrument guide, needle guide, hammer, hemostat, amputation hook, ligature passing and knot-tying instrument, knife, blood lancet, mallet, disposable or reusable aspiration and injection needle, disposable or reusable suturing needle, osteotome, pliers, rasp, retainer, retractor, saw, scalpel blade, scalpel handle, one-piece scalpel, snare, spatula, stapler, disposable or reusable stripper, stylet, suturing apparatus for the stomach and intestine, measuring tape, and calipers. A surgical instrument that has specialized uses in a specific medical specialty is classified in separate regulations in parts 868 through 892.
• Disposable Needles
• Disposable Syringes
• Endoscope Accessories (FDA Code: KOG)
• Enteral Irrigation Kit w/Piston Syringe
• Foley Catheter Introducer
• General & Plastic Surgery Laparoscope (FDA Code: GCJ / 876.1500)
An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.
• General EMT
• General Hypodermic Supplies
• General Medical Supplies
• General Surgery Supplies
• General Surgical Aids
• General Surgical Instruments
• Guidewire Catheter (FDA Code: DQX / 870.1330)
A catheter guide wire is a coiled wire that is designed to fit inside a percutaneous catheter for the purpose of directing the catheter through a blood vessel.
• Heat and Moisture Condenser (FDA Code: BYD / 868.5375)
A heat and moisture condenser (artificial nose) is a device intended to be positioned over a tracheotomy (a surgically created opening in the throat) or tracheal tube (a tube inserted into the trachea) to warm and humidify gases breathed in by a patient.
• Heat-Sealing Device (FDA Code: KSD / 864.9750)
A heat-sealing device is a device intended for medical purposes that uses heat to seal plastic bags containing blood or blood components.
• High Permeability with/without Sealed Dialysate System (FDA Code: KDI / 876.5860)
A high permeability hemodialysis system is a device intended for use as an artificial kidney system for the treatment of patients with renal failure, fluid overload, or toxemic conditions by performing such therapies as hemodialysis, hemofiltration, hemoconcentration, and hemodiafiltration. Using a hemodialyzer with a semipermeable membrane that is more permeable to water than the semipermeable membrane of the conventional hemodialysis system (876.5820), the high permeability hemodialysis system removes toxins or excess fluid from the patient's blood using the principles of convection (via a high ultrafiltration rate) and/or diffusion (via a concentration gradient in dialysate). During treatment, blood is circulated from the patient through the hemodialyzer's blood compartment, while the dialysate solution flows countercurrent through the dialysate compartment. In this process, toxins and/or fluid are transferred across the membrane from the blood to the dialysate compartment. The hemodialysis delivery machine controls and monitors the parameters related to this processing, including the rate at which blood and dialysate are pumped through the system, and the rate at which fluid is removed from the patient. The high permeability hemodialysis system consists of the following devices:
• Hollow Fiber Capillary Dialyzer (FDA Code: FJI / 876.5820)
A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.