Skype

Toyokagaku Co., Ltd.


Web: http://www.toyokagaku.com
Address: 1008 Terajiri-Oaza, Hino-Cho, Gamo-Gun, Shiga-Pref., Japan
Phone: +81-(748)-52-5000  | Fax: +81-(748)-53-0635 | Map/Directions >>
 
 

Profile: Toyokagaku Co., Ltd. is a manufacturer of medical tools, over-the-counter medications, medical treatment products, hygiene products and other medical related products.

FDA Registration Number: 3003793596
US Agent: Takahiro Haruyama / Globizz Corporation
Phone: +1-(310)-538-3860  Fax: +1-(310)-544-6753  E-Mail:

40 Products/Services (Click for related suppliers)  
• Adhesive Bandage Strip
• Adhesive Bandages (FDA Code: KGX / 880.5240)
A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists of a strip of fabric material or plastic, coated on one side with an adhesive, and may include a pad of surgical dressing without a disinfectant. The device is used to cover and protect wounds, to hold together the skin edges of a wound, to support an injured part of the body, or to secure objects to the skin.
• Adhesive Elastic Bandage Tape
• Anti-Regurgitation Valve with Blood Tubing Set (FDA Code: FJK / 876.5820)
A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.
• Blood Collection Systems (FDA Code: JKA / 862.1675)
A blood specimen collection device is a device intended for medical purposes to collect and to handle blood specimens and to separate serum from nonserum (cellular) components prior to further testing. This generic type device may include blood collection tubes, vials, systems, serum separators, blood collection trays, or vacuum sample tubes.
• Catheter Needle (FDA Code: GCB / 878.4200)
An introduction/drainage catheter is a device that is a flexible single or multilumen tube intended to be used to introduce nondrug fluids into body cavities other than blood vessels, drain fluids from body cavities, or evaluate certain physiologic conditions. Examples include irrigation and drainage catheters, pediatric catheters, peritoneal catheters (including dialysis), and other general surgical catheters. An introduction/drainage catheter accessory is intended to aid in the manipulation of or insertion of the device into the body. Examples of accessories include adaptors, connectors, and catheter needles.
• Cohesive Elastic Bandage
• Cohesive Elastic Bandage Wrap
• Dialysis Transducer Protector (FDA Code: FIB / 876.5820)
• Disposable Aspiration and Injection Needle (FDA Code: GAA / 878.4800)
A manual surgical instrument for general use is a nonpowered, hand-held, or hand-manipulated device, either reusable or disposable, intended to be used in various general surgical procedures. The device includes the applicator, clip applier, biopsy brush, manual dermabrasion brush, scrub brush, cannula, ligature carrier, chisel, clamp, contractor, curette, cutter, dissector, elevator, skin graft expander, file, forceps, gouge, instrument guide, needle guide, hammer, hemostat, amputation hook, ligature passing and knot-tying instrument, knife, blood lancet, mallet, disposable or reusable aspiration and injection needle, disposable or reusable suturing needle, osteotome, pliers, rasp, retainer, retractor, saw, scalpel blade, scalpel handle, one-piece scalpel, snare, spatula, stapler, disposable or reusable stripper, stylet, suturing apparatus for the stomach and intestine, measuring tape, and calipers. A surgical instrument that has specialized uses in a specific medical specialty is classified in separate regulations in parts 868 through 892.
• Elastic Adhesive Bandages
• Elastic Bandage with Removable Clip
• Elastic Bandages (FDA Code: FQM / 880.5075)
An elastic bandage is a device consisting of either a long flat strip or a tube of elasticized material that is used to support and compress a part of a patient's body.
• Elastomeric Infusion Pump (FDA Code: MEB / 880.5725)
An infusion pump is a device used in a health care facility to pump fluids into a patient in a controlled manner. The device may use a piston pump, a roller pump, or a peristaltic pump and may be powered electrically or mechanically. The device may also operate using a constant force to propel the fluid through a narrow tube which determines the flow rate. The device may include means to detect a fault condition, such as air in, or blockage of, the infusion line and to activate an alarm.
• Endoscope Accessories (FDA Code: KOG)
• Endoscopic Prescription Lens Eyepiece (FDA Code: FDZ / 876.1500)
An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.
• Extracorporeal Blood System and Accessories (FDA Code: LLB / 876.5820)
• Fistula Needle (FDA Code: FIE / 876.5540)
A blood access device and accessories is a device intended to provide access to a patient's blood for hemodialysis or other chronic uses. When used in hemodialysis, it is part of an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and provides access to a patient's blood for hemodialysis. The device includes implanted blood access devices, nonimplanted blood access devices, and accessories for both the implanted and nonimplanted blood access devices.
• Flexible Fabric Adhesive Bandages
• Guidewire Catheter (FDA Code: DQX / 870.1330)
A catheter guide wire is a coiled wire that is designed to fit inside a percutaneous catheter for the purpose of directing the catheter through a blood vessel.
• Hemodialysis Blood Circuit Accessories (FDA Code: KOC / 876.5820)
• High Flux Re-Use Hemodialyzer (FDA Code: MSF / 876.5860)
A high permeability hemodialysis system is a device intended for use as an artificial kidney system for the treatment of patients with renal failure, fluid overload, or toxemic conditions by performing such therapies as hemodialysis, hemofiltration, hemoconcentration, and hemodiafiltration. Using a hemodialyzer with a semipermeable membrane that is more permeable to water than the semipermeable membrane of the conventional hemodialysis system (876.5820), the high permeability hemodialysis system removes toxins or excess fluid from the patient's blood using the principles of convection (via a high ultrafiltration rate) and/or diffusion (via a concentration gradient in dialysate). During treatment, blood is circulated from the patient through the hemodialyzer's blood compartment, while the dialysate solution flows countercurrent through the dialysate compartment. In this process, toxins and/or fluid are transferred across the membrane from the blood to the dialysate compartment. The hemodialysis delivery machine controls and monitors the parameters related to this processing, including the rate at which blood and dialysate are pumped through the system, and the rate at which fluid is removed from the patient. The high permeability hemodialysis system consists of the following devices:
• High Permeability with/without Sealed Dialysate System (FDA Code: KDI / 876.5860)
• Hollow Fiber Capillary Dialyzer (FDA Code: FJI / 876.5820)
• Implanted Subcutaneous Intravascular Port & Catheter (FDA Code: LJT / 880.5965)
A subcutaneous, implanted, intravascular infusion port and catheter is a device that consists of a subcutaneous, implanted reservoir that connects to a long-term intravascular catheter. The device allows for repeated access to the vascular system for the infusion of fluids and medications and the sampling of blood. The device consists of a portal body with a resealable septum and outlet made of metal, plastic, or combination of these materials and a long-term intravascular catheter is either preattached to the port or attached to the port at the time of device placement. The device is available in various profiles and sizes and can be of a single or multiple lumen design.
• Insulin Infusion Pump (FDA Code: LZG / 880.5725)
• Intravenous Administration Kit (FDA Code: FPA / 880.5440)
An intravascular administration set is a device used to administer fluids from a container to a patient's vascular system through a needle or catheter inserted into a vein. The device may include the needle or catheter, tubing, a flow regulator, a drip chamber, an infusion line filter, an I.V. set stopcock, fluid delivery tubing, connectors between parts of the set, a side tube with a cap to serve as an injection site, and a hollow spike to penetrate and connect the tubing to an I.V. bag or other infusion fluid container.
• Low Flux Re-Use Hemodialyzer (FDA Code: MSE / 876.5820)
• Manual Vacuum-Assisted Blood Collect System (FDA Code: KST / 864.9125)
A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to draw blood for subsequent reinfusion.
• Non-Adhesive Bandages
• Non-Implanted Hemodialysis Catheters (FDA Code: MPB / 876.5540)
• Piston Syringe (FDA Code: FMF / 880.5860)
A piston syringe is a device intended for medical purposes that consists of a calibrated hollow barrel and a movable plunger. At one end of the barrel there is a male connector (nozzle) for fitting the female connector (hub) of a hypodermic single lumen needle. The device is used to inject fluids into, or withdraw fluids from, the body.
• Rubber Elastic Bandages
• Self Adhesive Elastic Bandage
• Short-Term Less Than 30 Days Therapeutic Intravascular Catheter (FDA Code: FOZ / 880.5200)
An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patient's vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or administer fluids intravenously. The device may be constructed of metal, rubber, plastic, or a combination of these materials.
• Single Lumen Hypodermic Needle (FDA Code: FMI / 880.5570)
A hypodermic single lumen needle is a device intended to inject fluids into, or withdraw fluids from, parts of the body below the surface of the skin. The device consists of a metal tube that is sharpened at one end and at the other end joined to a female connector (hub) designed to mate with a male connector (nozzle) of a piston syringe or an intravascular administration set.
• Sterile Specimen Container (FDA Code: FMH / 864.3250)
A specimen transport and storage container, which may be empty or prefilled, is a device intended to contain biological specimens, body waste, or body exudate during storage and transport in order that the matter contained therein can be destroyed or used effectively for diagnostic examination. If prefilled, the device contains a fixative solution or other general purpose reagent to preserve the condition of a biological specimen added to the container. This section does not apply to specimen transport and storage containers that are intended for use as part of an over-the-counter test sample collection system for drugs of abuse testing.
• Stopcock, I.V.Set (FDA Code: FMG / 880.5440)
• Tubular Elastic Bandage Retainer
• Tubular Elastic Bandages & Nets

 Edit or Enhance this Company (349 potential buyers viewed listing,  82 forwarded to manufacturer's website)
Browse Category   |   Alphabetical Products   |   ALL 25,000 Suppliers
HomeBuyAdd FREE ListingAdvertise Medical CompanyMedical Portal