Profile: Abbott Hematology offers pharmaceutical, medical, and nutritional products. Our product range comprises of medicines, medical diagnostic instruments & tests, minimally invasive surgical devices, and a spectrum of nutritional supplements for infants, children & adults. Our perclose A-T suture medicated closure provides the security of a braided polyester suture and ease of an automated knot for vascular closure. It is designed to provide complete tissue apposition resulting in primary healing. It provides reduced time to hemostasis ambulation and discharge. Our perclose proglide suture mediated closure is a monofilament suture that ensures vessel closure.
The company has ~72000 employees and is ISO 9001, CE certified. NYSE:ABT (SEC Filings)
FDA Registration Number: 2919069
• Total Thyroxine Non-Radiolabeled Enzyme Immunoassay (FDA Code: KLI / 862.1700) A total thyroxine test system is a device intended to measure total (free and protein bound) thyroxine (thyroid hormone) in serum and plasma. Measurements obtained by this device are used in the diagnosis and treatment of thyroid diseases. |
• Total Thyroxine Radioimmunoassay (FDA Code: CDX / 862.1700) |
• Total Triiodothyronine Radioimmunoassay (FDA Code: CDP / 862.1710) A total triiodothyronine test system is a device intended to measure the hormone triiodothyronine in serum and plasma. Measurements obtained by this device are used in the diagnosis and treatment of thyroid diseases such as hyperthyroidism. |
• Toxoplasma Gondii Enzyme Linked Immunoabsorbent Assay (FDA Code: LGD / 866.3780) |
• Transfer Aid (FDA Code: IKX / 890.5050) A daily activity assist device is a modified adaptor or utensil (e.g., a dressing, grooming, recreational activity, transfer, eating, or homemaking aid) that is intended for medical purposes to assist a patient to perform a specific function. |
• Transfer Aid for Disabled/Handicapped (FDA Code: IKX / 890.5050) |
• Transferrin Antigen (FDA Code: DDG / 866.5880) A transferrin immunological test system is a device that consists of the reagents used to measure by immunochemical techniques the transferrin (an iron-binding and transporting serum protein) in serum, plasma, and other body fluids. Measurement of transferrin levels aids in the diagnosis of malnutrition, acute inflammation, infection, and red blood cell disorders, such as iron deficiency anemia. |
• Tricyclic Antidepressant Drugs Radioimmunoassay Test (FDA Code: LFG / 862.3910) A tricyclic antidepressant drugs test system is a device intended to measure any of the tricyclic antidepressant drugs in serum. The tricyclic antidepressant drugs include imipramine, desipramine, amitriptyline, nortriptyline, protriptyline, and doxepin. Measurements obtained by this device are used in the diagnosis and treatment of chronic depression to ensure appropriate therapy. |
• Tricyclic Antidepressant Drugs U.V. Spectrometry (FDA Code: LFH / 862.3910) |
• Triglycerides Lipase Hydrolysis/Glycerol Kinase Enzyme Test (FDA Code: CDT / 862.1705) A triglyceride test system is a device intended to measure triglyceride (neutral fat) in serum and plasma. Measurements obtained by this device are used in the diagnosis and treatment of patients with diabetes mellitus, nephrosis, liver obstruction, other diseases involving lipid metabolism, or various endocrine disorders. |
• Triiodothyronine Uptake Radioassay (FDA Code: KHQ / 862.1715) A triiodothyronine uptake test system is a device intended to measure the total amount of binding sites available for binding thyroid hormone on the thyroxine-binding proteins, thyroid-binding globulin, thyroxine-binding prealbumin, and albumin of serum and plasma. The device provides an indirect measurement of thyrkoxine levels in serum and plasma. Measurements of triiodothyronine uptake are used in the diagnosis and treatment of thyroid disorders. |
• Troponin Subunit Enzymatic Method (FDA Code: MMI / 862.1215) A creatine phosphokinase/creatine kinase or isoenzymes test system is a device intended to measure the activity of the enzyme creatine phosphokinase or its isoenzymes (a group of enzymes with similar biological activity) in plasma and serum. Measurements of creatine phosphokinase and its isoenzymes are used in the diagnosis and treatment of myocardial infarction and muscle diseases such as progressive, Duchenne-type muscular dystrophy. |
• Tumor Antigen Immunological Test System (FDA Code: MOI / 866.6010) A tumor-associated antigen immunological test system is a device that consists of reagents used to qualitatively or quantitatively measure, by immunochemical techniques, tumor-associated antigens in serum, plasma, urine, or other body fluids. This device is intended as an aid in monitoring patients for disease progress or response to therapy or for the detection of recurrent or residual disease. |
• U.V. Method, CPK/Isoenzymes (FDA Code: JHW / 862.1215) |
• Urea Nitrogen Ion Specific Electrode (FDA Code: CDS / 862.1770) A urea nitrogen test system is a device intended to measure urea nitrogen (an end-product of nitrogen metabolism) in whole blood, serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment of certain renal and metabolic diseases. |
• Urea Nitrogen Urease and Glutamic Dehydrogenase Test (FDA Code: CDQ / 862.1770) |
• Uric Acid, Uricase (FDA Code: CDO / 862.1775) A uric acid test system is a device intended to measure uric acid in serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment of numerous renal and metabolic disorders, including renal failure, gout, leukemia, psoriasis, starvation or other wasting conditions, and of patients receiving cytotoxic drugs. |
• Urinary Ketones, Nitroprusside Test (FDA Code: JIN / 862.1435) A ketones (nonquantitative) test system is a device intended to identify ketones in urine and other body fluids. Identification of ketones is used in the diagnosis and treatment of acidosis (a condition characterized by abnormally high acidity of body fluids) or ketosis (a condition characterized by increased production of ketone bodies such as acetone) and for monitoring patients on ketogenic diets and patients with diabetes. |
• Urine Screening Kit (FDA Code: JXA / 866.2660) A microorganism differentiation and identification device is a device intended for medical purposes that consists of one or more components, such as differential culture media, biochemical reagents, and paper discs or paper strips impregnated with test reagents, that are usually contained in individual compartments and used to differentiate and identify selected microorganisms. The device aids in the diagnosis of disease. |
• Valproic Acid Enzyme Immunoassay Test (FDA Code: LEG / 862.3645) A neuroleptic drugs radioceptor assay test system is a device intended to measure in serum or plasma the dopamine receptor blocking activity of neuroleptic drugs and their active metabolites. A neuroleptic drug has anti-psychotic action affecting principally psychomotor activity, is generally without hypnotic effects, and is a tranquilizer. Measurements obtained by this device are used to aid in determining whether a patient is taking the prescribed dosage level of such drugs. |
• Vancomycin Radioimmunoassay (FDA Code: LEH / 862.3950) A vancomycin test system is a device intended to measure vancomycin, an antibiotic drug, in serum. Measurements obtained by this device are used in the diagnosis and treatment of vancomycin overdose and in monitoring the level of vancomycin to ensure appropriate therapy. |
• Vascular Hemostasis Device (FDA Code: MGB) |
• Vitamin B12 Radioimmunoassay (FDA Code: CDD / 862.1810) A vitamin B12test system is a device intended to measure vitamin B12in serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment of anemias of gastrointestinal malabsorption. |
• Wall Vacuum-Powered Operating Room Suction Apparatus (FDA Code: GCX / 880.6740) A vacuum-powered body fluid suction apparatus is a device used to aspirate, remove, or sample body fluids. The device is powered by an external source of vacuum. This generic type of device includes vacuum regulators, vacuum collection bottles, suction catheters and tips, connecting flexible aspirating tubes, rigid suction tips, specimen traps, noninvasive tubing, and suction regulators (with gauge). |