Briot-Weco Australia Pty Ltd
Briot-Weco Australia Pty Ltd
Akriti Oculoplasty Logistics,
Visine Instruments,
Briot-Weco Australia Pty Ltd
Briot-Weco Australia Pty Ltd
Haag-Streit USA,
Akriti Oculoplasty Logistics,
Venus Surgical & Health Care,
more...
Eyekon Medical,
Carl Zeiss Co., Ltd.,
Ioltech Laboratories
(FDA Code:
LQE)
Addition Technology Inc.,
Revision Optics, Inc,
Imperial Medical Technologies,
more...
(FDA Code:
MWD)
Refractec, Inc.
Abbott Medical Optics, Inc.,
Carl Zeiss Co., Ltd.
Refractive phakic IOL is a powerful refractive tool with almost unlimited potential to correct refractive errors such as nearsightedness and farsightedness. It is unique in that the thin intraocular lens implant is placed in the eye without removing the natural lens of the eye, as is required in cataract surgery. It is typically available in powers of -5.0 to -20.0 diopters (D) of power, making it an option for patients with both moderate and severe degrees of myopia.
Staar Surgical Company,
Abbott Medical Optics, Inc.,
Carl Zeiss Co., Ltd.
Becton, Dickson & Co.,,
Vectorvision,
Nidek Co., Ltd.,
more...
Epikeratome is a fully automated system with a disposable head that enables surgeons to perform a new refractive procedure known as Epi-Lasik. The Epi-K is utilized to mechanically cleave the epithelium from the membrane leaving a pristine optical zone for laser ablation. It preserves the structural integrity of the stroma and is expected to minimize discomfort, shorten the length of visual recovery, and reduce the incidence of haze associated with other surface ablation procedures.
Advanced Refractive Technologies,
Norwood EyeCare Pty. Ltd.,
Moria S.A.
Refractive surgery, Pupillometer is a device used to measure pupils and screen candidates for refractive procedures and other ophthalmic applications such as the fitting of multifocal intraocular lenses (IOLs) and orthokeratology. It can accurately measure pupils in total darkness.
Oasis Medical, Inc.,
FCI Ophthalmics
Refractive surgery, Thermokeratoplasty is a type of refractive surgery procedure, in which the application of heat shrinks the collagen of the corneal stroma and flattens the cornea in the area of heat application.
Sunrise Technologies International, Inc.,
Refractec, Inc.
Grafton Optical,
Briot-Weco Australia Pty Ltd
Regular multipurpose solution is used to clean, disinfect, rinse, store, rewet, and remove protein deposits from soft contact lenses.
Abbott Medical Optics, Inc.,
Alcon Laboratories, Inc
Nidek Inc.,
Marco,
Topcon America Corporation,
more...
Oasis Medical, Inc.,
LKC Technologies, Inc.,
Oculus, Inc.,
more...
(FDA Code:
NKX /
886.467)
Identification. A phacofragmentation system is an AC-powered device with a fragmenting needle intended for use in cataract surgery to disrupt a cataract with ultrasound and extract the cataract.
Classification. Class II.
American Optisurgical Inc.,
Sterilmed, Inc.,
Medisiss,
more...
Heidelberg Engineering, Inc.,
Paradigm Medical Industries, Inc.,
Beckman Coulter, Inc.,
more...
Medone Surgical, Inc.,
Newtech Brush Co Ltd
Heidelberg Engineering, Inc.
Medtronic Ophthalmics,
Dutch Ophthalmic USA
FCI Ophthalmics,
Universal Medical Products,
Wesley Coe (Cambridge) Ltd.,
more...
Oasis Medical, Inc.,
Medone Surgical, Inc.,
Dutch Ophthalmic USA
(FDA Code:
LOG)
Howard Instruments, Inc.
(FDA Code:
LPO /
886.427)
Identification. An intraocular gas is a device consisting of a gaseous fluid intended to be introduced into the eye to place pressure on a detached retina.
Classification. Class III.
Air Liquide America Specialty Gases,LLC.,
Air Liquide Healthcare America Corporation
Medtronic Ophthalmics,
Dutch Ophthalmic USA,
Robbins Instruments, Inc.,
more...
Retinal thickness analysis is an objective method to assess and quantify the retinal thickness in healthy controls and in diabetics without diabetic retinopathy. It uses a computerized laser slit lamp to measure retinal thickness at the central 20 degrees of the macula, and overlays a map of measurements on the patient's retinal image.
Talia Technology Ltd.
Retinal thickness analysis (RTA) is an objective method to assess and quantify the retinal thickness in healthy controls and in diabetics without diabetic retinopathy.
Talia Technology Ltd.
Retinal thickness analyzer uses a computerized laser slit lamp to measure retinal thickness at the central 20 degrees of the macula, and overlays a map of measurements on the patient's retinal image. It can detect and document as little as 34mm of macular edema, which may cause disturbances in central vision. It can be used to monitor progression of macular thickening as diabetic macular edema increases or resolves in response to local and/or systemic therapy.
Oasis Medical, Inc.,
Becton, Dickson & Co.,
Oasis Medical, Inc.,
Ambu Inc,
Akriti Oculoplasty Logistics,
more...
The retinoscope is an instrument used to measure the refraction of the eye. It is used in retinoscopy technique that is used to obtain an objective measurement of the refractive condition of a patient's eye. The examiner uses a retinoscope to shine light into the patient's eye and observes the reflection (reflex) off the patient's retina.
Veatch Ophthalmic Instruments,
ProTech Ophthalmics,
Oasis Medical, Inc.,
more...
Vitreoretinal surgery, Scleral buckle implant is produced by a piece of silicone sponge, rubber, or semi-hard plastic. It is placed on the outer layer of the eye by the ophthalmologist. The material is sewn to the eye to keep it in place. The buckling element is usually left in place permanently.
Eye Technology Ltd.
Pro Orthopedic Devices
Howard Instruments, Inc.,
Advanced Vision Science Inc.,
Water Pik, Inc.,
more...
Rusch Inc.,
Sontec Instruments, Inc.,
Autosuture,
more...
Cambrian Medical Inc.,
Medtronic Ophthalmics
Right handed mayo scissors are used for cutting heavy fascia and sutures. These scissors are mainly constructed from stainless steel materials. It is available in many shapes, styles and sizes. It is designed for right-handed use.
Pro Orthopedic Devices,
DENOVO Dental Inc.,
Masel,
more...
Precision Vision, Ltd.,
Danker Laboratories, Inc.,
Omni Optical Lab,
more...
Rigid Gas Permeable contact lenses offer many benefits including crisp vision, high oxygen permeability, and myopia control. It is more resistant to proteins and other deposits, making them easier to clean.
Precision Vision, Ltd.,
Ciba Vision,
Alcon Laboratories, Inc,
more...
Paragon Vision Sciences,
Precision Vision, Ltd.,
Art Optical Contact Lens Inc.,
more...
(FDA Code:
MRC /
886.5918)
Identification. A rigid gas permeable contact lens care product is a device intended for use in the cleaning, conditioning, rinsing, lubricating/rewetting, or storing of a rigid gas permeable contact lens. This includes all solutions and tablets used together with rigid gas permeable contact lenses.
Classification. Class II (Special Controls) Guidance Document: "Guidance for Industry Premarket Notification (510(k)) Guidance Document for Contact Lens Care Products."
Paragon Vision Sciences,
Abbott Medical Optics, Inc.,
Ciba Vision,
more...
Almore International Inc.,
Fuzhou Core Medical Science Co., Ltd
Rotatory visual evoked potential is an experimental paradigm for eliciting visual evoked potentials whose dipole source appears to be outside the primary occipital cortex (posterior temporal).
Oasis Medical, Inc.
Eye chart is necessary to make comparisons and to record people's visual acuity. Types of eye charts include the Snellen chart, Landolt C, and the Lea test. It usually displays several rows of test symbols, each row in a different size. The person is asked to identify the numbers or letters on the chart, usually starting with large rows and continuing to smaller rows until the optotypes cannot be reliably identified anymore.
Eye Technology Ltd.
Topcon America Corporation,
Masunaga Optical Mfg. Co., Ltd.
GAM Laser, Inc.,
M & M Co., Ltd.
Medtronic Ophthalmics,
Robbins Instruments, Inc.,
Radiation Products Design, Inc.,
more...
Veatch Ophthalmic Instruments,
Ophtec USA Inc.