PRODUCT NAME | FDA Code/Regulation |
Daily Wear Soft Contact Lenses (70 suppliers)
Daily wear soft contact lenses are the perfect solution for people with vision problems who do not wish to have surgery and do not like the feel and visual appearance of eyeglasses. It is made of polymer-plastic materials that are flexible. It allows oxygen to pass through to the cornea, and provides great comfort. It is easy to adjust.
Identification. A soft (hydrophilic) contact lens is a device intended to be worn directly against the cornea and adjacent limbal and scleral areas of the eye to correct vision conditions or act as a therapeutic bandage. The device is made of various polymer materials the main polymer molecules of which absorb or attract a certain volume (percentage) of water. Classification. (1) Class II if the device is intended for daily wear only. | LPL / 886.5925 |
Data Processing Module for Clinical use (82 suppliers) Identification. A calculator/data processing module for clinical use is an electronic device intended to store, retrieve, and process laboratory data. Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in 862.9. | JQP / 862.2100 |
Decontamination Kit (9 suppliers)
Decontamination Kit includes items such as protective clothing, plastic overshoes, plastic aprons or disposable oversuit, box disposable gloves, disposable face masks, small forceps or remote handling tools and soft nail brush.
| MAC / 878.4014 |
Defibrillator Testers (14 suppliers)
Defibrillator tester is connected to the output of the defibrillator and is used to measure the energy delivered by the defibrillator into a standard resistive load. Some testers also provide waveform information. It operates on automatic or semiautomatic manner. It determines energy, peak voltage, current and cardio sync.
Identification. A defibrillator tester is a device that is connected to the output of a defibrillator and is used to measure the energy delivered by the defibrillator into a standard resistive load. Some testers also provide waveform information. Classification. Class II (performance standards). | DRL / 870.5325 |
Denis Brown Splint (17 suppliers) Identification. A Denis Brown splint is a device intended for medical purposes to immobilize the foot. It is used on young children with tibial torsion (excessive rotation of the lower leg) or club foot. Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in 890.9. The device is also exempt from the current good manufacturing practice requirements of the quality system regulation in part 820 of this chapter, with the exception of 820.180, regarding general requirements concerning records and 820.198, regarding complaint files. | ITN / 890.3675 |
Densitometers (14 suppliers) Identification. A densitometer is a device used to measure the transmission of light through an indicator in a sample of blood. Classification. Class II (performance standards). | DXM / 870.1450 |
Dental Accessories Tissue Culture (5 suppliers) Identification. Cell and tissue culture supplies and equipment are devices that are used to examine, propagate, nourish, or grow cells and tissue cultures. These include such articles as slide culture chambers, perfusion and roller apparatus, cell culture suspension systems, and tissue culture flasks, disks, tubes, and roller bottles. Classification. Class I (general controls). These devices are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in 864.9. If the devices are not labeled or otherwise represented as sterile, they are exempt from the current good manufacturing practice requirements of the quality system regulation in part 820 of this chapter, with the exception of 820.180, with respect to general requirements concerning records, and 820.198, with respect to complaint files. | NVG / 864.2240 |
Dental Automatic Radiographic-Film Processor (3 suppliers) Identification. An automatic radiographic film processor is a device intended to be used to develop, fix, wash, and dry automatically and continuously film exposed for medical purposes. Classification. Class II. | EGY / 892.1900 |
Dental Computed Tomography X-Ray (7 suppliers) Identification. A computed tomography x-ray system is a diagnostic x-ray system intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data from the same axial plane taken at different angles. This generic type of device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories. Classification. Class II. | OAS / 892.1750 |
Dental Protector (33 suppliers) Identification. A dental protector is a device intended to protect a patient's teeth during manipulative procedures within a patient's oral cavity. Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in 868.9. | BRW / 868.5820 |
Dental Suture (3 suppliers) | DZG |
Depth Electrodes (12 suppliers) Identification. A depth electrode is an electrode used for temporary stimulation of, or recording electrical signals at, subsurface levels of the brain. Classification. Class II (performance standards). | GZL / 882.1330 |
Depth Gauge (116 suppliers) Identification. A depth gauge for clinical use is a measuring device intended for various medical purposes, such as to determine the proper length of screws for fastening the ends of a fractured bone. Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in 888.9. | HTJ / 888.4300 |
Dermabrasion Brush (52 suppliers) Identification. Surgical instrument motors and accessories are AC-powered, battery-powered, or air-powered devices intended for use during surgical procedures to provide power to operate various accessories or attachments to cut hard tissue or bone and soft tissue. Accessories or attachments may include a bur, chisel (osteotome), dermabrasion brush, dermatome, drill bit, hammerhead, pin driver, and saw blade. Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to 878.9. | GFE / 878.4820 |
Dermal Biopsy Punch (27 suppliers) Identification. A gastroenterology-urology biopsy instrument is a device used to remove, by cutting or aspiration, a specimen of tissue for microscopic examination. This generic type of device includes the biopsy punch, gastrointestinal mechanical biopsy instrument, suction biopsy instrument, gastro-urology biopsy needle and needle set, and nonelectric biopsy forceps. This section does not apply to biopsy instruments that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations. Classification. (1) Class II (performance standards). | FCI / 876.1075 |
Dermal Replacement Device (2 suppliers) | MDD |
Dermatological Therapeutic X-Ray Collimator (1 supplier) Identification. An x-ray radiation therapy system is a device intended to produce and control x-rays used for radiation therapy. This generic type of device may include signal analysis and display equipment, patient and equipment supports, treatment planning computer programs, component parts, and accessories. Classification. Class II. | IYL / 892.5900 |
Dermatological Therapeutic X-Ray Generator (2 suppliers) Identification. An x-ray radiation therapy system is a device intended to produce and control x-rays used for radiation therapy. This generic type of device may include signal analysis and display equipment, patient and equipment supports, treatment planning computer programs, component parts, and accessories. Classification. Class II. | IYH / 892.5900 |
Dermatological Ultraviolet Light (22 suppliers) Identification. An ultraviolet lamp for dermatologic disorders is a device (including a fixture) intended to provide ultraviolet radiation of the body to photoactivate a drug in the treatment of a dermatologic disorder if the labeling of the drug intended for use with the device bears adequate directions for the device's use with that drug. Classification. Class II. | FTC / 878.4630 |
Dermatomes (51 suppliers) Identification. Surgical instrument motors and accessories are AC-powered, battery-powered, or air-powered devices intended for use during surgical procedures to provide power to operate various accessories or attachments to cut hard tissue or bone and soft tissue. Accessories or attachments may include a bur, chisel (osteotome), dermabrasion brush, dermatome, drill bit, hammerhead, pin driver, and saw blade. Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to 878.9. | GFD / 878.4820 |
Dermatophyte Identification Kit (1 supplier) Identification. A microorganism differentiation and identification device is a device intended for medical purposes that consists of one or more components, such as differential culture media, biochemical reagents, and paper discs or paper strips impregnated with test reagents, that are usually contained in individual compartments and used to differentiate and identify selected microorganisms. The device aids in the diagnosis of disease. Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to 866.9. | JSR / 866.2660 |
Desoxycorticosterone Radioimmunoassay Test (2 suppliers) Identification. A desoxycorticosterone test system is a device intended to measure desoxycorticosterone (DOC) in plasma and urine. DOC measurements are used in the diagnosis and treatment of patients with hypermineralocorticoidism (excess retention of sodium and loss of potassium) and other disorders of the adrenal gland. Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to 862.9. | JLE / 862.1250 |
Detection And Identification Nucleic Acid Or Antigen 2009 H1n1 Influenza Virus (Swine Origin) (2 suppliers) | OQW / 866.3332 |
Detection And Identification Nucleic Acid Or Antigen 2009 H1n1 Influenza Virus (Swine Origin) Reagents (1 supplier) | OPU |
Detergent (33 suppliers) | JCB / 864.4010 |
Diabetes Take Home Kit (1 supplier) | OSS |
Diagnostic Automated Blood Cell Separator (13 suppliers) | GKT / 864.9245 |
Diagnostic Biliary Catheter (53 suppliers) Identification. A biliary catheter and accessories is a tubular flexible device used for temporary or prolonged drainage of the biliary tract, for splinting of the bile duct during healing, or for preventing stricture of the bile duct. This generic type of device may include a bile collecting bag that is attached to the biliary catheter by a connector and fastened to the patient with a strap. Classification. Class II (performance standards). | FGE / 876.5010 |
Diagnostic Blood Bank Centrifuge (17 suppliers) Identification. A blood bank centrifuge for in vitro diagnostic use is a device used only to separate blood cells for further diagnostic testing. Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to 864.9. | KSO / 864.9275 |
Diagnostic Condensing Lens (15 suppliers) Identification. A diagnostic condensing lens is a device used in binocular indirect ophthalmoscopy (a procedure that produces an inverted or reversed direct magnified image of the eye) intended to focus reflected light from the fundus of the eye. Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in 886.9. The device is also exempt from the current good manufacturing practice requirements of the quality system regulation in part 820 of this chapter, with the exception of 820.180, with respect to general requirements concerning records, and 820.198, with respect to complaint files. | HJL / 886.1380 |
Diagnostic Electromyograph (36 suppliers) Identification. A diagnostic electromyograph is a device intended for medical purposes, such as to monitor and display the bioelectric signals produced by muscles, to stimulate peripheral nerves, and to monitor and display the electrical activity produced by nerves, for the diagnosis and prognosis of neuromuscular disease. Classification. Class II (performance standards). | IKN / 890.1375 |
Diagnostic Electromyograph Needle Electrode (15 suppliers) Identification. A diagnostic electromyograph needle electrode is a monopolar or bipolar needle intended to be inserted into muscle or nerve tissue to sense bioelectrical signals. The device is intended for medical purposes for use in connection with electromyography (recording the intrinsic electrical properties of skeletal muscle). Classification. Class II (performance standards). | IKT / 890.1385 |
Diagnostic Eye Movement Monitor (3 suppliers) Identification. An eye movement monitor is an AC-powered device with an electrode intended to measure and record ocular movements. Classification. Class II. | HMC / 886.1510 |
Diagnostic Flexible Fresnel Lens (11 suppliers) Identification. A flexible diagnostic Fresnel lens is a device that is a very thin lens which has its surface a concentric series of increasingly refractive zones. The device is intended to be applied to the back of the spectacle lenses of patients with aphakia (absence of the lens of the eye). Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in 886.9. The device is also exempt from the current good manufacturing practice requirements of the quality system regulation in part 820 of this chapter, with the exception of 820.180, with respect to general requirements concerning records, and 820.198, with respect to complaint files. | HJJ / 886.1390 |
Diagnostic Hruby Fundus Lens (8 suppliers) Identification. A diagnostic Hruby fundus lens is a device that is a 55 diopter lens intended for use in the examination of the vitreous body and the fundus of the eye under slitlamp illumination and magnification. Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in 886.9. The device is also exempt from the current good manufacturing practice requirements of the quality system regulation in part 820 of this chapter, with the exception of 820.180, with respect to general requirements concerning records, and 820.198, with respect to complaint files. | HJI / 886.1395 |
Diagnostic Incandescent Light Source (5 suppliers) Identification. An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations. Classification. (1) Class II (performance standards). | FCQ / 876.1500 |
Diagnostic Intravascular Catheter (79 suppliers) Identification. An intravascular diagnostic catheter is a device used to record intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among others. Classification. Class II (performance standards). | DQO / 870.1200 |
Diagnostic Mediastinoscope (2 suppliers) Identification. An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations. Classification. (1) Class II (performance standards). | GCH / 876.1500 |
Diagnostic Muscle Stimulator (9 suppliers) Identification. A diagnostic muscle stimulator is a device used mainly with an electromyograph machine to initiate muscle activity. It is intended for medical purposes, such as to diagnose motor nerve or sensory neuromuscular disorders and neuromuscular function. Classification. Class II (performance standards). | ISB / 890.1850 |
Diagnostic Polymethylmethacrylate Contact Lens (10 suppliers) Identification. A polymethylmethacrylate (PMMA) diagnostic contact lens is a device that is a curved shell of PMMA intended to be applied for a short period of time directly on the globe or cornea of the eye for diagnosis or therapy of intraocular abnormalities. Classification. Class II. | HJK / 886.1385 |
Diagnostic Pulmonary Function Interpretator/Calculator (8 suppliers) Identification. A diagnostic pulmonary-function interpretation calculator is a device that interprets pulmonary study data to determine clinical significance of pulmonary-function values. Classification. Class II (performance standards). | BZM / 868.1900 |
Diagnostic Spirometer (68 suppliers) Identification. A diagnostic spirometer is a device used in pulmonary function testing to measure the volume of gas moving in or out of a patient's lungs. Classification. Class II (performance standards). | BZG / 868.1840 |
Diagnostic Ultrasonic Transducer (149 suppliers) Identification. A diagnostic ultrasonic transducer is a device made of a piezoelectric material that converts electrical signals into acoustic signals and acoustic signals into electrical signals and intended for use in diagnostic ultrasonic medical devices. Accessories of this generic type of device may include transmission media for acoustically coupling the transducer to the body surface, such as acoustic gel, paste, or a flexible fluid container. Classification. Class II. | ITX / 892.1570 |
Diagnostic X-Ray Beam Limiting Device (15 suppliers) Identification. A diagnostic x-ray beam-limiting device is a device such as a collimator, a cone, or an aperture intended to restrict the dimensions of a diagnostic x-ray field by limiting the size of the primary x-ray beam. Classification. Class II. | KPW / 892.1610 |
Diagnostic X-Ray High Voltage Generator (41 suppliers) Identification. A diagnostic x-ray high voltage generator is a device that is intended to supply and control the electrical energy applied to a diagnostic x-ray tube for medical purposes. This generic type of device may include a converter that changes alternating current to direct current, filament transformers for the x-ray tube, high voltage switches, electrical protective devices, or other appropriate elements. Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in 892.9. | IZO / 892.1700 |
Diagnostic X-Ray Tube Housing Assembly (29 suppliers) Identification. A diagnostic x-ray tube housing assembly is an x-ray generating tube encased in a radiation-shielded housing that is intended for diagnostic purposes. This generic type of device may include high voltage and filament transformers or other appropriate components. Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in 892.9. | ITY / 892.1760 |
Diagnostic X-Ray Tube Mount (30 suppliers) Identification. A diagnostic x-ray tube mount is a device intended to support and to position the diagnostic x-ray tube housing assembly for a medical radiographic procedure. Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in 892.9. | IYB / 892.1770 |
Diagnostic/Surgical Loupe (50 suppliers) Identification. A manual surgical instrument for general use is a nonpowered, hand-held, or hand-manipulated device, either reusable or disposable, intended to be used in various general surgical procedures. The device includes the applicator, clip applier, biopsy brush, manual dermabrasion brush, scrub brush, cannula, ligature carrier, chisel, clamp, contractor, curette, cutter, dissector, elevator, skin graft expander, file, forceps, gouge, instrument guide, needle guide, hammer, hemostat, amputation hook, ligature passing and knot-tying instrument, knife, blood lancet, mallet, disposable or reusable aspiration and injection needle, disposable or reusable suturing needle, osteotome, pliers, rasp, retainer, retractor, saw, scalpel blade, scalpel handle, one-piece scalpel, snare, spatula, stapler, disposable or reusable stripper, stylet, suturing apparatus for the stomach and intestine, measuring tape, and calipers. A surgical instrument that has specialized uses in a specific medical specialty is classified in separate regulations in parts 868 through 892. Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in 878.9. | FSP / 878.4800 |
Dialysate Delivery System Disinfectant (1 supplier) Identification. A high permeability hemodialysis system is a device intended for use as an artificial kidney system for the treatment of patients with renal failure, fluid overload, or toxemic conditions by performing such therapies as hemodialysis, hemofiltration, hemoconcentration, and hemodiafiltration. Using a hemodialyzer with a semipermeable membrane that is more permeable to water than the semipermeable membrane of the conventional hemodialysis system (876.5820), the high permeability hemodialysis system removes toxins or excess fluid from the patient's blood using the principles of convection (via a high ultrafiltration rate) and/or diffusion (via a concentration gradient in dialysate). During treatment, blood is circulated from the patient through the hemodialyzer's blood compartment, while the dialysate solution flows countercurrent through the dialysate compartment. In this process, toxins and/or fluid are transferred across the membrane from the blood to the dialysate compartment. The hemodialysis delivery machine controls and monitors the parameters related to this processing, including the rate at which blood and dialysate are pumped through the system, and the rate at which fluid is removed from the patient. The high permeability hemodialysis system consists of the following devices: Classification. Class II. The special controls for this device are FDA's: | NII / 876.5860 |
Dialysate Flowmeter (1 supplier) Identification. A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer. Classification. (1) Class II (performance standards) for hemodialysis systems and all accessories directly associated with the extracorporeal blood system and the dialysate delivery system. | FIS / 876.5820 |